... ... @@ -197,6 +197,7 @@
197 197  * This packet must match the frequency of the RX1 or RX2 window.
198 198  * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). **This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
199 199  
200 +
200 200  == 5.2 See Debug Info ==
201 201  
202 202  (((
... ... @@ -211,7 +211,7 @@
211 211  Configure a downstream to the end device
212 212  )))
213 213  
214 -[[image:https://wiki.dragino.com/images/thumb/8/82/Downstream_debug_1.png/600px-Downstream_debug_1.png||height="217" width="600"]]
215 +[[image:image-20220526164623-12.png]]
215 215  
216 216  (((
217 217  Set a downstream in TTN and see it is sent
... ... @@ -222,7 +222,7 @@
222 222  This downstream info will then pass to the gateway downstream list. and include the DR which is used (SF9BW125) in EU868 is DR3
223 223  )))
224 224  
225 -[[image:https://wiki.dragino.com/images/thumb/d/dc/Downstream_debug_2.png/600px-Downstream_debug_2.png||height="245" width="600"]]
226 +[[image:image-20220526164650-13.png]]
226 226  
227 227  (((
228 228  Gateway Traffic can see this downstream info
... ... @@ -237,7 +237,7 @@
237 237  When the downstream packet appear on the traffic of Gateway page. The LoRaWAN gateway can get it from LoRaWAN server and transmit it. In Dragion Gateway, this can be checked by runinng "logread -f" in the SSH console. and see below:
238 238  )))
239 239  
240 -[[image:https://wiki.dragino.com/images/thumb/2/21/Downstream_debug_3.png/600px-Downstream_debug_3.png||height="195" width="600"]]
241 +[[image:image-20220526164734-14.png]]
241 241  
242 242  (((
243 243  Gateway Sent out this packet
... ... @@ -297,6 +297,9 @@
297 297   Receive data
298 298   1:0012345678}}}
299 299  
301 +(% class="wikigeneratedid" %)
302 +​​​​​​​
303 +
300 300  == 5.3 If problem doesn’t solve ==
301 301  
302 302  **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:**
... ... @@ -465,3 +465,5 @@
465 465  (Any combination of 16 bit codes can be used)