Show last authors
1 **Contents:**
2
3 {{toc/}}
4
5
6 = **1. Introduction** =
7
8 Dragino Gateway is possible to support (LBT) Listen Before Talk feature with [[LA66 USB LoRaWAN Adapter>>doc:Main.User Manual for LoRaWAN End Nodes.LA66 LoRaWAN Module.WebHome]].
9
10
11 = **2. How to use** =
12
13 == **2.1 Upgrade File** ==
14
15 Upgrade the firmware to the LBT version for specific device [[Firmware download>>https://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Release/LBT--build-v5.4.1658454438-20220722-0948/]], [[Firmware Changelog>>url:http://www.dragino.com/downloads/downloads/LoRa_Gateway/LG308-LG301/Firmware/ChangeLog]]. This LBT version firmware support LBT by default, users just need to plug in the LA66 USB LoRaWAN Adapter.
16
17
18 [[image:image-20220722105144-1.jpeg||height="419" width="559"]]
19
20 == **2.2 Debug** ==
21
22 Apply and save on the web after the above configure has been made
23
24 (((
25 run "(% style="color:#037691" %)**logread -f**"(%%) in Linux to check the LBT running status.
26
27 If LA66 module returned the value "(% style="color:#037691" %)**FREE"**(%%), indicating that can be downlinked normally.
28
29 If LA66 module returned the value "(% style="color:#037691" %)**BUSY"**(%%), indicates that the downlink can be disturbed.
30
31 [[image:image-20220705110001-5.png||height="681" width="1375"]]
32
33
34 == **2.3 Trouble Shootings** ==
35
36
37 === **How to debug if LBT does not work** ===
38
39 Make sure that the gateway is connected to the LA66 module, Can check by command or via the Web UI.
40
41 [[image:image-20220705104342-4.png||height="760" width="1005"]]
42
43 [[image:image-20220705104316-3.png||height="574" width="1005"]]
44
45
46 Access LA66 module log will show CP210X Converter Now Attached to **ttyUSBX**
47
48 [[image:image-20220705111448-6.png||height="249" width="1003"]]
49 )))