Xiaoling 1.2 3 = 1. Introduction =
Xiaoling 1.1 4
Edwin Chen 4.1 5 This chapter describes how to set Transmit Time Interva[[l for Dragino Senso>>https://End Device AT Commands and Downlink Command/#H4.1ChangeUplinkInterval]]rs.
Xiaoling 1.1 6
Edwin Chen 4.1 7 = 2. via AT Command through UART interface =
Xiaoling 1.1 8
Edwin Chen 4.1 9
10
11 (% class="wikigeneratedid" %)
12 = 3. via LoRaWAN Downlink =
13
Xiaoling 1.2 14 TDC can be controlled by Downlink Payload.
Xiaoling 1.1 15
Xiaoling 2.2 16 (((
Xiaoling 1.2 17 For example: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
Xiaoling 2.2 18 )))
Xiaoling 1.1 19
Xiaoling 1.2 20 [[image:https://wiki.dragino.com/images/8/8e/TDC.png||alt="TDC.png" height="173" width="850"]]
Xiaoling 1.1 21
Xiaoling 2.2 22 (((
23
24 )))
Xiaoling 1.1 25
Xiaoling 2.2 26 (((
Xiaoling 2.1 27 If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01.
Xiaoling 2.2 28 )))
Xiaoling 2.1 29
Xiaoling 2.2 30 (((
Xiaoling 1.2 31 Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
Xiaoling 2.2 32 )))
Xiaoling 1.1 33
Xiaoling 3.2 34 [[image:image-20220512084801-1.png]]
Xiaoling 1.1 35
Xiaoling 1.2 36 = 3. Downlink Method =
Xiaoling 1.1 37
Xiaoling 2.1 38 See use note for different serves [[Servers Note>>http://8.211.40.43:8080/xwiki/bin/view/Main/]]