From version < 9.1 >
edited by Edwin Chen
on 2022/05/12 11:31
To version < 6.1 >
edited by Edwin Chen
on 2022/05/12 11:20
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,29 +2,18 @@
2 2  
3 3  = 1. Introduction =
4 4  
5 -This chapter describes how to set Transmit Time Interval for [[label>>End Device AT Commands and Downlink Command/||anchor="#H4.1ChangeUplinkInterval"]].
5 +This chapter describes how to set Transmit Time Interval for [[Dragino Sensors>>Dragino Sensors]].
6 6  
7 7  = 2. via AT Command through UART interface =
8 8  
9 9  
10 -|=(% colspan="3" %)AT+TDC
11 -|**Command Example**|**Function**|**Response**
12 -|AT+TDC=?|Show current transmit Interval|30000(((
13 -OK
14 14  
15 -the interval is 30000ms = 30s
16 -)))
17 -|AT+TDC=60000|Set Transmit Interval|OK(((
18 -Set transmit interval to 60000ms = 60 seconds
19 -)))
20 -
21 -
22 22  = 3. via LoRaWAN Downlink =
23 23  
24 24  TDC can be controlled by Downlink Payload.
25 25  
26 26  (((
27 -For example: Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
16 +For example: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
28 28  )))
29 29  
30 30  [[image:https://wiki.dragino.com/images/8/8e/TDC.png||alt="TDC.png" height="173" width="850"]]
... ... @@ -43,6 +43,6 @@
43 43  
44 44  [[image:image-20220512084801-1.png]]
45 45  
46 -== Downlink Method ==
35 += 3. Downlink Method =
47 47  
48 48  See use note for different serves [[Servers Note>>http://8.211.40.43:8080/xwiki/bin/view/Main/]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0