... ... @@ -1,26 +1,38 @@
1 -
1 +**~ Table of Contents:**
2 2  
3 +{{toc/}}
4 +
5 +
6 +
7 +
3 3  = 1. Introduction =
4 4  
10 +
5 5  This chapter describes how to set Transmit Time Interval.
6 6  
13 +
7 7  = 2. Downlink Payload =
8 8  
16 +
9 9  TDC can be controlled by Downlink Payload.
10 10  
11 11  (((
12 -**For example**: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
20 +**For example**: AT+TDC=0x258=600s ** ; Payload: **01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
13 13  )))
14 14  
15 -[[image:https://wiki.dragino.com/images/8/8e/TDC.png||alt="TDC.png" height="173" width="850"]]
23 +[[image:image-20220527085044-1.png]]
16 16  
17 17  
18 -If the payload=0100003C, it means set the END Nodes TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01.
26 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01.
19 19  
20 -Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
28 +**Payload: **01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
21 21  
22 -[[image:image-20220512115239-1.png]]
30 +[[image:image-20220527085157-3.png]]
23 23  
24 -== 3. Downlink Method ==
25 25  
26 -See use note for different serves [[Servers Note>>http://8.211.40.43:8080/xwiki/bin/view/Main/]]
33 += 3. Downlink Method =
34 +
35 +
36 +See use  note for different serves [[Servers Note>>doc:Main.WebHome]](IoT LoRaWAN Server)