Hide last authors
Edwin Chen 8.1 1 **Table of Contents:**
2
3 {{toc/}}
4
5
Xiaoling 11.2 6
Xiaoling 10.2 7 = 1. Overview =
Edwin Chen 1.1 8
Xiaoling 10.2 9
Edwin Chen 1.1 10 There are some new models of Dragino sensors support OTA update via Private LoRa Protocol, (Even the sensor runs LoRaWAN protocol by default)
11
12
Xiaoling 10.2 13 = 2. Support Models =
14
15
Edwin Chen 1.1 16 Here list the models that support OTA Update.
17
Edwin Chen 2.1 18
Edwin Chen 1.1 19 {{velocity}}
20 $xwiki.ssfx.use("js/xwiki/table/table.css")
21 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
22 {{/velocity}}
23
Xiaoling 20.2 24 (% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f2f2f2; width:670px" %)
Xiaoling 11.4 25 (% class="sortHeader" %)|=(% style="width: 193px;background-color:#D9E2F3" %)Models|=(% style="width: 222px;background-color:#D9E2F3" %)Firmware Version|=(% style="width: 251px;background-color:#D9E2F3" %)Comments
Xiaoling 11.2 26 |(% style="width:193px" %)PS-LB, SDI-12-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
Edwin Chen 11.1 27 |(% style="width:193px" %)SN50v3-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
Edwin Chen 12.1 28 |(% style="width:193px" %)D20-LB/D20S/LB/D22-LB/D23-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
29 |(% style="width:193px" %)(((
30 LHT65N-PIR,LHT65N-E31F
31 )))|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
32 |(% style="width:193px" %)S31-LB, S31B-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
Edwin Chen 2.1 33
Xiaoling 20.2 34
Xiaoling 10.2 35 = 3. How to do OTA update =
36
37 == 3.1 Required Components ==
38
39
Edwin Chen 7.1 40 * Hardware: [[LA66 USB>>doc:Main.User Manual for LoRaWAN End Nodes.LA66 USB LoRaWAN Adapter User Manual.WebHome]] with [[OTA_firmware>>https://www.dropbox.com/sh/4qnjreg1esxu16i/AADbRjW_tuBP3IIkmf11nSoma?dl=0]] installed.
Xiaoling 20.2 41
Edwin Chen 7.1 42 * Software: [[OTA_Tool>>https://www.dropbox.com/sh/4qnjreg1esxu16i/AADbRjW_tuBP3IIkmf11nSoma?dl=0]]. Only support Windows now
43
Edwin Chen 16.1 44 [[image:image-20230513120722-2.png||height="409" width="866"]]
Edwin Chen 7.1 45
Edwin Chen 14.1 46
Edwin Chen 21.1 47 (% class="wikigeneratedid" %)
48 == 3.2 Video Instruction ==
Xiaoling 10.2 49
50
Edwin Chen 21.1 51 (% class="wikigeneratedid" %)
52 Instruction ~-~- OTA Upgrade Firmware (via LoRa) of LoRaWAN Sensors**: [[https:~~/~~/youtu.be/SSvOqvBrwGg>>https://youtu.be/SSvOqvBrwGg]]**
53
54 (% class="wikigeneratedid" %)
55 == ==
56
57 == 3.3 Update Steps ==
58
59
Xiaoling 10.2 60 === (% style="color:blue" %)**Step1 :**(%%) Plug LA66 USB to PC and run OTA_Tool. ===
61
62
Edwin Chen 7.1 63 [[image:image-20230114172703-1.png]]
64
65
Xiaoling 10.2 66 === (% style="color:blue" %)**Step2:**(%%) Set up OTA Tool ===
Edwin Chen 7.1 67
68
Xiaoling 10.2 69 * (% style="color:blue" %)**DevEUI**(%%): Input Dev EUI of your sensor
70
71 * (% style="color:blue" %)**Password**(%%): Passord of your sensor
72
73 * (% style="color:blue" %)**Port**(%%): Com port of LA66 USB
74
75 * (% style="color:blue" %)**LoRa_Freq**(%%): Choose the shipped frequency band of your sensor.
76
77 * (% style="color:blue" %)**Upload_File**(%%): The firmware to be upload to the sensor. make sure the firmware is with surfix _without_bootloader. For example: LHT65N_EU868_v1.5_without_bootloader.
78
79 * (% style="color:blue" %)**EUI File**(%%): If customer has lots of sensors. He can also import the Dev EUI files and use droplist to choose the sensor to update. Format is as below:
80
Edwin Chen 7.1 81 [[image:image-20230114174640-3.png||height="130" width="1169"]]
82
83
Xiaoling 10.2 84 === (% style="color:blue" %)**Step3:**(%%) Press Start in OTA Tool and then Press Reset button to restart LA66 USB ===
Edwin Chen 7.1 85
Xiaoling 10.2 86
Edwin Chen 7.1 87 After press reset button, LA66 USB will restart and broadcast update process with the Dev EUI and Password.
88
89
Xiaoling 10.2 90 === (% style="color:blue" %)**Step4:** (%%)Press reset button on the end node, or re-activate the end node. ===
Edwin Chen 7.1 91
Xiaoling 10.2 92
Edwin Chen 7.1 93 In every reboot/ reactivate, the end node will check if there is update request. If end node gets the update request from LA66. End node will check if the Dev EUI and Password match. If match, End node will establish connection with LA66 USB for OTA update.
94
95
Xiaoling 10.2 96 === (% style="color:blue" %)**Step5:**(%%) Check result. ===
Edwin Chen 7.1 97
Xiaoling 10.2 98
Edwin Chen 7.1 99 Below shows the update successul result.
100
101 [[image:image-20230114174134-2.png]]
102
103
Edwin Chen 14.1 104 = 4. FAQ =
Edwin Chen 7.1 105
Edwin Chen 14.1 106 == 4.1 Can i use other devices to connect to PC if i don't have LA66 USB? ==
107
108
Xiaoling 20.2 109 If user doesn't have LA66 USB Adapter, they can still use other Dragino Device to connect to PC for OTA update.
110
111 (% style="color:blue" %)**Steps:**
112
Edwin Chen 14.1 113 * Find the suitable mode which base on LA66 chip ( All LoRaWAN model with LB or LS suffix , such as SN50v3-LB)
Xiaoling 20.2 114
Edwin Chen 14.1 115 * Update the LA66 USB OTA firmware to the device.
Xiaoling 20.2 116
Edwin Chen 14.1 117 * Connect the device to PC via UART interface.
Xiaoling 20.2 118
Edwin Chen 14.1 119 * Make sure power off or update the firmware back to original firmware , because the LA66 USB OTA fimware is not low power consumption firmware. it will consume the battery very fast.
120
Xiaoling 20.2 121
Edwin Chen 19.1 122 == 4.2 Where to find OTA Password? ==
123
Xiaoling 20.2 124
Edwin Chen 19.1 125 Each device has a shipped label with OTA Password which is 16 chars. like below. If user don't find this, please send us a photo for the device with Dev EUI to [[support@dragino.com>>mailto:support@dragino.com]] . and we will search the password for you.
126
127 [[image:image-20230519102907-2.png||height="286" width="580"]]
128
129
Edwin Chen 20.1 130 == 4.3 How about if i upgrade a crashed firmware via OTA update? ==
Edwin Chen 19.1 131
Edwin Chen 20.1 132
Xiaoling 20.2 133 OTA update is done via Bootloader and only change the firmware partition. So update a crash firmware via OTA update won't destroy bootloader and user can use OTA method to update again.
Edwin Chen 20.1 134
Xiaoling 20.2 135 (% style="color:red" %)**Here are notice:**
Edwin Chen 20.1 136
Xiaoling 20.2 137 ~1. OTA update frequency depend on the firmware frequency. If there is no frequency in the firmware. Bootloader will use EU868 as default frequency.
Edwin Chen 20.1 138
Xiaoling 20.2 139 2. OTA update require a reset or reactivate action. If the crash firmware doesn't have them work, user need to manuall push the physic reset button on the PCB or power off/on device.
140
141
Edwin Chen 14.1 142 = 5. OTA Tool Known Bug: =
143
144
Xiaoling 10.2 145 ~1. If user click "(% style="color:blue" %)**Start**"(%%) but there is issue during update. User may need to close and open the tool again.
Edwin Chen 7.1 146
147