Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -4,15 +4,17 @@
4 4  
5 5  
6 6  
7 -= Overview =
7 += 1. Overview =
8 8  
9 +
9 9  This URL introduce different methods to detect the water / liquid level.
10 10  
11 11  
12 -= Flow switch =
13 += 2. Flow switch =
13 13  
14 -== How it works ==
15 +== 2.1 How it works ==
15 15  
17 +
16 16  Below is an example of flow switch. and product link:
17 17  
18 18  [[https:~~/~~/www.amazon.com/Float-Switch-Septic-System-Sump/dp/B0064BHEVM/ref=sr_1_5?crid=2PCMSD63FBP42&keywords=float%2Bswitch&qid=1671230997&refinements=p_72%3A1248909011&rnid=1248907011&s=hi&sprefix=float%2Bswitch%2Caps%2C155&sr=1-5&th=1 >>https://www.amazon.com/Float-Switch-Septic-System-Sump/dp/B0064BHEVM/ref=sr_1_5?crid=2PCMSD63FBP42&keywords=float%2Bswitch&qid=1671230997&refinements=p_72%3A1248909011&rnid=1248907011&s=hi&sprefix=float%2Bswitch%2Caps%2C155&sr=1-5&th=1]]
... ... @@ -19,6 +19,7 @@
19 19  
20 20  [[image:image-20221217164157-1.png||height="329" width="486"]]
21 21  
24 +
22 22  [[image:image-20221217164432-3.png||height="282" width="501"]][[image:image-20221217164337-2.png||height="279" width="431"]]
23 23  
24 24  The switch will switch on/off to show if the water / liquid has dedicate level.
... ... @@ -29,18 +29,18 @@
29 29  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#H2.4.5DigitalInterrupt >>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/#H2.4.5DigitalInterrupt]]
30 30  
31 31  
32 -== Advantage & Disadvantage ==
35 +== 2.2 Advantage & Disadvantage ==
33 33  
34 -**Advantage** : Reliable , Easy to install & Immue to different environment.
35 35  
36 -**Disadvantage**: Only be able to detect one speicify level. Not able to detect full range of water.
38 +(% style="color:blue" %)**Advantage**(%%) : Reliable , Easy to install & Immue to different environment.
37 37  
40 +(% style="color:red" %)**Disadvantage**(%%): Only be able to detect one speicify level. Not able to detect full range of water.
38 38  
39 39  
43 += 3. Ultrasonic Sensor =
40 40  
41 -= Ultrasonic Sensor =
45 +== 3.1 How it works? ==
42 42  
43 -== How it works? ==
44 44  
45 45  Such as [[LDDS75>>https://www.dragino.com/products/distance-level-sensor/item/161-ldds75.html]] / [[LDDS45>>https://www.dragino.com/products/distance-level-sensor/item/191-ldds45.html]]. They are using ultrasonic technologic to detect the distance between the probe and a flat object such as water level.
46 46  
... ... @@ -56,31 +56,34 @@
56 56  An important notice, if there are moisture accumulated in the sense area of Ultrasonic Probe of LDDS75/LDDS45. the reading will become invalid.
57 57  
58 58  
59 -== Advantage & Disadvantage ==
62 +== 3.2 Advantage & Disadvantage ==
60 60  
61 -**Advantage** : Able to detect the level. Good Accurancy.
62 62  
63 -**Disadvanage**: Wrong reading when probe is block by moisture or other stuff. Affect by temperature.
65 +(% style="color:blue" %)**Advantage**(%%) :  Able to detect the level. Good Accurancy.
64 64  
67 +(% style="color:red" %)**Disadvanage**(%%): Wrong reading when probe is block by moisture or other stuff. Affect by temperature.
65 65  
66 -= Pressure Sensor =
67 67  
68 -== How it works? ==
70 += 4. Pressure Sensor =
69 69  
72 +== 4.1 How it works? ==
73 +
74 +
70 70  Pressure Sensor such as [[PS-LB>>https://www.dropbox.com/sh/eshhuk347xi1ce4/AAA4LUmYc2ITayfJUVsqK3wya?dl=0]] measures the pressure of the air / gas / liquid so can calcualte the liquid level.
71 71  
72 -there are two types , **Thread type** and **Immersion type**. as below:
77 +there are two types , (% style="color:blue" %)**Thread type** (%%)and (% style="color:blue" %)**Immersion type**(%%). as below:
73 73  
74 74  
75 75  [[image:image-20221228143643-1.png||height="223" width="312"]] [[image:image-20221228144206-2.png||height="256" width="335"]]
76 76  
77 77  
78 -== Advantage & Disadvantage ==
83 +== 4.2 Advantage & Disadvantage ==
79 79  
80 -**Advantage** : Able to detect air / gas / liquid pressure level. Immue to factors such as moisture / blocking. etc. Flexible for installation for
81 81  
82 -**Disadvanage**:
86 +(% style="color:blue" %)**Advantage**(%%) :  Able to detect air / gas / liquid pressure level. Immue to factors such as moisture / blocking. etc. Flexible for installation for
83 83  
88 +(% style="color:red" %)**Disadvanage **(%%):
84 84  
85 85  
91 +
86 86  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved