1 | = For BC95-G = | ||
2 | |||
3 | ~1. Check the reason why you can't access the network: | ||
4 | |||
5 | 1) AT+CEREG=5 | ||
6 | |||
7 | 2) AT+CEREG? ~/~/This process may be longer, please repeat the input | ||
8 | |||
9 | 3) Mainly check the two parameters cause_type and reject_case | ||
10 | |||
11 | [[image:https://wiki.dragino.com/images/1/19/BC-95-G1.png||alt="BC-95-G1.png" height="366" width="558"]] | ||
12 | |||
13 | 2. Network access operation: | ||
14 | |||
15 | 1) AT+CFUN=0 | ||
16 | |||
17 | 2) AT+NBAND=X ~/~/X means the local frequency band number | ||
18 | |||
19 | 3) AT+NRB | ||
20 | |||
21 | 4) After waiting for a period of time, you can use AT+CSQ to query the network access | ||
22 | |||
23 | [[image:https://wiki.dragino.com/images/2/24/BC-95-G2.png||alt="BC-95-G2.png" height="365" width="558"]] | ||
24 | |||
25 | Remarks: | ||
26 | |||
27 | ~1. The operating voltage of the SIM card used must be less than 3.0V | ||
28 | |||
29 | 2. The network access time varies with the signal strength | ||
30 | |||