2 = Overview: =
3
4 In LoRaWAN protocol, the gateway transmit packet use the output power base on the Power Index from LoRaWAN server downlink. for example: LoRaWAN server send downlink with this info "rf_power=14", gatewat got this info and it will search the index for rf_power=14 and use the related rf setting to set output power. In some case, the LoRaWAN server might set the rf-power to a quite low value ( for example 0dB) which is not practical for use. In such case, User can manunal change the rf_power=0's rf settings to a higher power out. Below are the methods.
5
6
7 = Change Power for Semtech UDP Paket forward connection =
8
9 ----
10
11 In LoRaWAN protocol, the gateway output power refer to the downstream packets sent by Gateway. This output power is controlled by LoRaWAN server.
12
13 Gateway maintain a power index in the file: /etc/lora/global_conf.json for example:
14
15
16 (% class="box" %)
17 (((
18 "tx_lut_3": {
19 "desc": "TX gain table, index 3",        ~/~/ Index 3 refer to rf_power: 15dB. device will set the pa_gain,mix_gain,dig_gain 
20 "pa_gain": 2,                            ~/~/ to the value mentioned here so to generate 15dB output power.
21 "mix_gain": 10,
22 "rf_power": 15,
23 "dig_gain": 1
24 },
25 "tx_lut_4": {
26 "desc": "TX gain table, index 4",
27 "pa_gain": 2,
28 "mix_gain": 10,
29 "rf_power": 16,
30 "dig_gain": 0
31 )))
32
33 (% class="mark" %)Note: If when lorawan server specify a rf_power which is not list above. gateway will choose the closest power. profile.
34
35
36 When LoRaWAN server sends a downlink stream, server will also ask the gateway to use which rf_power as output. So user don't need to consider to control in the gateway side.
37
38 If user want to always use a higher power or a lower power. User can modify the pa_gain,mix_gain,dig_gain for specify rf_power to achieve this purpose. This is not recommended, because this might break the regulator for specific country.
39
40 Please note, that the global_conf.json file will be overwritten by the match region files in /etc/lora/cfg-30x when changing settings in the web. So user needs to change the files in /etc/lora/cfg-cfg-30x instead of global_conf.json