<
From version < 63.1 >
edited by Xiaoye
on 2024/04/07 14:41
To version < 71.1 >
edited by Kilight Cao
on 2024/04/09 09:20
>
Change comment: Uploaded new attachment "image-20240409092052-1.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoye
1 +XWiki.Kilight
Content
... ... @@ -20,7 +20,7 @@
20 20  
21 21  
22 22  
23 -= 2. Support hardrware & Software =
23 += (% data-sider-select-id="f76aa92f-2814-4139-b8f4-fffb711c6bf8" %)2. Support hardrware & Software(%%) =
24 24  
25 25  
26 26  {{velocity}}
... ... @@ -306,7 +306,7 @@
306 306  )))|(% style="background-color:#f2f2f2; width:392px" %)(((
307 307  * Add Write Decode Data to the register function
308 308  )))
309 -|(% style="background-color:#f2f2f2; width:126px" %)2024-04-05|(% style="background-color:#f2f2f2; width:252px" %)(((
309 +|(% style="background-color:#f2f2f2; width:126px" %)2024-04-07|(% style="background-color:#f2f2f2; width:252px" %)(((
310 310  dragino-ui
311 311  
312 312  draginomodbus
... ... @@ -313,7 +313,7 @@
313 313  )))|(% style="background-color:#f2f2f2; width:392px" %)(((
314 314  * Add the Reset button for the Web UI
315 315  * Fix long payloads not being written to Modbus registers.
316 -* Fixes issue where reset would lose configurations
316 +* Fixes issue where reset would lose configurations or not to work
317 317  * Fixed reset without restoring static IP settings
318 318  * Fixed reset without restoring fallback/ssh settings
319 319  * Fixed DNS resolution error after static IP setting
... ... @@ -349,22 +349,38 @@
349 349  
350 350  
351 351  
352 -= 4. Disable OTA Update =
352 += (% data-sider-select-id="500d7a08-0205-47a2-85e6-1fc121490096" %)4. Disable OTA Update(%%) =
353 353  
354 354  
355 +(% data-sider-select-id="df136b0e-8b86-49e7-bbf3-0afec1d11738" %)
355 355  It is possible for clients to disable the OTA update feature. Below is the instruction:
356 356  
357 357  
358 -=== LPS8V2: ===
359 +== (% data-sider-select-id="c057c426-f69a-4116-86aa-5c5a2bdb3cbd" %)LPS8V2:(%%) ==
359 359  
360 360  [[image:image-20230830104754-1.png||height="472" width="878"]]
361 361  
362 362  
363 -=== LPS8/LPS8N/DLOS8/DLOS8N/LG308/LG308N: ===
364 +== (% data-sider-select-id="efafd320-602c-4e03-b246-f68076fe4c0c" %)LPS8/LPS8N/DLOS8/DLOS8N/LG308/LG308N:(%%) ==
364 364  
365 365  
366 -* Using Command Line
367 +* (((
368 +(% data-sider-select-id="58d62ab1-d8be-4375-8863-abf1bb86cf9b" %)
369 +(% data-sider-select-id="09bc9630-075f-4f0a-b5f3-9af2ab071930" %)**Method 1:**(%%) (% data-sider-select-id="27e66d6b-0e3d-4a23-9578-bd9a3db88413" %)**Upload the backup file and reboot**
370 +)))
367 367  
372 +
373 +(% data-sider-select-id="45fbfb29-9446-4b9c-bea8-b8d8546c723c" %)
374 +Download the backup file in this link: **[[attach:remove_auto_update.tar.gz||data-sider-select-id="e663678f-e38b-4485-b60f-e2bb222fbc32" target="_blank"]]**
375 +
376 +(% data-sider-select-id="07db0b3d-d2aa-4a93-8b55-97d286f54b5d" %)
377 +When the user has finished uploading the backup file, the gateway needs to be reboot, and the gateway will disable the OTA update feature.
378 +
379 +[[image:image-20240408175151-1.png]]
380 +
381 +
382 +* (% data-sider-select-id="20710c15-9603-4a3f-9f83-f80932f331fe" %)**Method 2:**(%%) (% data-sider-select-id="92117512-6f07-4e63-9e74-e117990dfe9a" %)**Using Command Line**
383 +
368 368  (% class="box infomessage" %)
369 369  (((
370 370  sed -i 's/0 2 \* \* \* \/etc\/init.d\/opkg-update start/\#0 2 \* \* \* \/etc\/init.d\/opkg-update start/g' /etc/crontabs/root
image-20240408175151-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +64.0 KB
Content
image-20240409092052-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +82.4 KB
Content
remove_auto_update.tar.gz
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +471 bytes
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0