Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 61.1
edited by Karry Zhuang
on 2025/07/15 15:42
on 2025/07/15 15:42
Change comment:
There is no comment for this version
To version 59.1
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,7 +21,6 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 27 27 * **Temperature Accuracy: **±0.5 °C ... ... @@ -28,7 +28,6 @@ 28 28 * **Working environment:** 29 29 ** Ambient Temperature: 0–60°C 30 30 ** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -47,12 +47,10 @@ 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 49 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -127,8 +127,6 @@ 127 127 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 128 128 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 129 129 130 - 131 - 132 132 === 1.7.2 Change address === 133 133 134 134 ... ... @@ -207,8 +207,6 @@ 207 207 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 208 208 209 209 210 -ECK200 211 - 212 212 === 1.7.5 Calibration Method === 213 213 214 214
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content