... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -21,14 +21,13 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -47,12 +47,10 @@ 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 50 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -127,8 +127,6 @@ 127 127 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 128 128 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 129 129 130 - 131 - 132 132 === 1.7.2 Change address === 133 133 134 134 ... ... @@ -273,9 +273,7 @@ 273 273 274 274 * **Temperature measurement error**: ±0.5°C 275 275 276 -* **Working environment:** 277 -** Ambient Temperature: 0–60°C 278 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 271 +* **Temperature Measure Range**: -20 ~~ 60 °C 279 279 280 280 * **Temperature Accuracy: **±0.5 °C 281 281 ... ... @@ -482,9 +482,7 @@ 482 482 483 483 * **Stability**: ≤2mv/24 hours 484 484 485 -* **Working environment:** 486 -** Ambient Temperature: 0–60°C 487 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 488 488 489 489 * **IP Rated**: IP68 490 490 ... ... @@ -655,11 +655,11 @@ 655 655 == 4.1 Specification == 656 656 657 657 658 -* **Measuring range**: 0-20mg/L, 0 –50℃649 +* **Measuring range**: 0-20mg/L, 0-50°C 659 659 660 -* **Accuracy**: 3%, ±0.5 ℃651 +* **Accuracy**: 3%, ±0.5°C 661 661 662 -* **Resolution**: 0.01 mg/L, 0.01 ℃653 +* **Resolution**: 0.01 mg/L, 0.01°C 663 663 664 664 * **Maximum operating pressure**: 6 bar 665 665 ... ... @@ -667,9 +667,7 @@ 667 667 668 668 * **Power supply voltage**: 5-24V DC 669 669 670 -* **Working environment:** 671 -** Ambient Temperature: 0–60°C 672 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 661 +* **Working environment**: temperature 0-60°C; humidity <95%RH 673 673 674 674 * **Power consumption**: ≤0.5W 675 675 ... ... @@ -796,9 +796,7 @@ 796 796 797 797 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 798 798 799 -* **Working environment:** 800 -** Ambient Temperature: 0–60°C 801 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 802 802 803 803 * **Power consumption**: ≤ 0.5W 804 804
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content