Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.8
edited by Karry Zhuang
on 2025/07/15 15:39
on 2025/07/15 15:39
Change comment:
There is no comment for this version
To version 61.6
edited by Karry Zhuang
on 2025/07/15 15:57
on 2025/07/15 15:57
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -111,7 +111,6 @@ 111 111 112 112 === 1.7.1 Query address === 113 113 114 -ECK1 and ECK10.0 115 115 116 116 **send:** 117 117 ... ... @@ -130,8 +130,6 @@ 130 130 131 131 132 132 133 -ECK200.0 134 - 135 135 === 1.7.2 Change address === 136 136 137 137 ... ... @@ -210,8 +210,11 @@ 210 210 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 211 211 212 212 210 +ECK200 211 + 213 213 === 1.7.5 Calibration Method === 214 214 214 +ECK1 and ECK10.0 215 215 216 216 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. 217 217 ... ... @@ -255,6 +255,23 @@ 255 255 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 256 256 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 257 257 258 + 259 + 260 +ECK200.0 261 + 262 +For the device with address 01, use 1413uS/cm standard solution to calibrate the first point. Send frame: 1413. Convert hexadecimal to 585. Write 0001, 00 00, 0585 to 0x0120, 0x0121, 0x0122 respectively. 263 + 264 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 265 +|=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register Address|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Register length|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data length|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Register contents|=(% style="width: 53px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 53px;background-color:#4F81BD;color:white" %)Data|=(% style="width: 53px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 53px;background-color:#4F81BD;color:white" %)CRC16 high 266 +|(% style="width:99px" %)0X01|(% style="width:112px" %)0X10|(% style="width:135px" %)0X01 0X02|(% style="width:126px" %)0X00 0X03|(% style="width:85px" %)0X06|(% style="width:1px" %)0X03|(% style="width:1px" %)0X04|(% style="width:1px" %)((( 267 +0X00 268 +0X00 269 +0X37 270 +0X32 271 +)))|(% style="width:1px" %)0XBD|(% style="width:1px" %)0XFC 272 + 273 + 274 + 258 258 = 2. DR-PH01 Water PH Sensor = 259 259 260 260 == 2.1 Specification ==