Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.7
edited by Karry Zhuang
on 2025/07/15 15:39
on 2025/07/15 15:39
Change comment:
There is no comment for this version
To version 61.2
edited by Karry Zhuang
on 2025/07/15 15:50
on 2025/07/15 15:50
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -111,7 +111,6 @@ 111 111 112 112 === 1.7.1 Query address === 113 113 114 -ECK1 and ECK10 115 115 116 116 **send:** 117 117 ... ... @@ -128,6 +128,8 @@ 128 128 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 129 129 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 130 130 130 + 131 + 131 131 === 1.7.2 Change address === 132 132 133 133 ... ... @@ -206,8 +206,11 @@ 206 206 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 207 207 208 208 210 +ECK200 211 + 209 209 === 1.7.5 Calibration Method === 210 210 214 +ECK1 and ECK10.0 211 211 212 212 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. 213 213 ... ... @@ -251,6 +251,11 @@ 251 251 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 252 252 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 253 253 258 + 259 + 260 +ECK200.0 261 + 262 + 254 254 = 2. DR-PH01 Water PH Sensor = 255 255 256 256 == 2.1 Specification ==