Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.6
edited by Karry Zhuang
on 2025/07/15 15:34
on 2025/07/15 15:34
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. karry1 +XWiki.Xiaoling - Content
-
... ... @@ -19,16 +19,15 @@ 19 19 * **EC Range & Resolution:** 20 20 ** **ECK0.01** : 0.02 ~~ 20 μS/cm 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 -** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 -** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 22 +** **ECK1.0** : 2 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 +** **ECK10.0** : 20 ~~ 20,000 μS/cm Resolution: 10 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -42,17 +42,15 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-2024 1129142314-1.png||height="352" width="1108"]]44 +[[image:image-20240720172533-1.png||height="347" width="569"]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 50 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -271,9 +271,7 @@ 271 271 272 272 * **Temperature measurement error**: ±0.5°C 273 273 274 -* **Working environment:** 275 -** Ambient Temperature: 0–60°C 276 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 271 +* **Temperature Measure Range**: -20 ~~ 60 °C 277 277 278 278 * **Temperature Accuracy: **±0.5 °C 279 279 ... ... @@ -480,14 +480,13 @@ 480 480 481 481 * **Stability**: ≤2mv/24 hours 482 482 483 -* **Working environment:** 484 -** Ambient Temperature: 0–60°C 485 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 486 486 487 487 * **IP Rated**: IP68 488 488 489 489 * **Max Pressure**: 0.6MPa 490 490 484 + 491 491 == 3.2 Wiring == 492 492 493 493 ... ... @@ -648,16 +648,18 @@ 648 648 0XC3 649 649 ))) 650 650 645 + 646 + 651 651 = 4. DR-DO1 Dissolved Oxygen Sensor = 652 652 653 653 == 4.1 Specification == 654 654 655 655 656 -* **Measuring range**: 0-20mg/L, 0 –50℃652 +* **Measuring range**: 0-20mg/L, 0-50°C 657 657 658 -* **Accuracy**: 3%, ±0.5 ℃654 +* **Accuracy**: 3%, ±0.5°C 659 659 660 -* **Resolution**: 0.01 mg/L, 0.01 ℃656 +* **Resolution**: 0.01 mg/L, 0.01°C 661 661 662 662 * **Maximum operating pressure**: 6 bar 663 663 ... ... @@ -665,9 +665,7 @@ 665 665 666 666 * **Power supply voltage**: 5-24V DC 667 667 668 -* **Working environment:** 669 -** Ambient Temperature: 0–60°C 670 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 664 +* **Working environment**: temperature 0-60°C; humidity <95%RH 671 671 672 672 * **Power consumption**: ≤0.5W 673 673 ... ... @@ -680,10 +680,9 @@ 680 680 == 4.3 Impedance requirements for current signals == 681 681 682 682 683 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 684 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 685 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 677 +[[image:image-20240718195414-8.png||height="100" width="575"]] 686 686 679 + 687 687 == 4.4 Mechinical Drawing == 688 688 689 689 ... ... @@ -782,7 +782,7 @@ 782 782 == 5.1 Specification == 783 783 784 784 785 -* **Measuring range**: 0.1 ~~1000.0NTU778 +* **Measuring range**: 0.11000.0NTU 786 786 787 787 * **Accuracy**: ±5% 788 788 ... ... @@ -790,13 +790,11 @@ 790 790 791 791 * **Stability**: ≤3mV/24 hours 792 792 793 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 786 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 794 794 795 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)788 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 796 796 797 -* **Working environment:** 798 -** Ambient Temperature: 0–60°C 799 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 790 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 800 800 801 801 * **Power consumption**: ≤ 0.5W 802 802 ... ... @@ -808,10 +808,11 @@ 808 808 809 809 == 5.3 Impedance requirements for current signals == 810 810 802 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:518px" %) 803 +|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 103.6px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 103.6px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 804 +|(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 805 +[[image:image-20240718195414-8.png||height="100" width="575"]] 811 811 812 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:400px" %) 813 -|(% style="width:132px" %)**Supply Voltage**|(% style="width:67px" %)**9V**|(% style="width:67px" %)**12V**|(% style="width:67px" %)**20V**|(% style="width:67px" %)**24V** 814 -|(% style="width:132px" %)**Max Impedance**|(% style="width:65px" %)**<250Ω**|(% style="width:67px" %)**<400Ω**|(% style="width:67px" %)**<500Ω**|(% style="width:65px" %)**<900Ω** 815 815 816 816 == 5.4 Mechinical Drawing == 817 817 ... ... @@ -885,9 +885,3 @@ 885 885 For example, the returned data is 15 03 02 (% style="color:red" %)**02 9A**(%%) 09 4C 886 886 887 887 02 9A is the turbidity value, converted to decimal, it is 666, and then divided by 10, the actual value is 66.6, 02 9A means the current turbidity value is 66.6 NTU 888 - 889 - 890 -= 6. Water Quality Sensor Datasheet = 891 - 892 - 893 -* **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]**
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content
- image-20241129142314-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.2 MB - Content