Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 60.10
edited by Karry Zhuang
on 2025/07/15 15:42
on 2025/07/15 15:42
Change comment:
There is no comment for this version
To version 53.1
edited by Karry Zhuang
on 2024/11/29 14:23
on 2024/11/29 14:23
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,14 +21,13 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 -** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 25 25 26 26 * **EC Accuracy**: ±1% FS 26 + 27 +* **Temperature Measure Range**: -20 ~~ 60 °C 28 + 27 27 * **Temperature Accuracy: **±0.5 °C 28 -* **Working environment:** 29 -** Ambient Temperature: 0–60°C 30 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 -** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 + 32 32 * **IP Rated**: IP68 33 33 34 34 * **Max Pressure**: 0.6MPa ... ... @@ -42,17 +42,15 @@ 42 42 == 1.3 Wiring == 43 43 44 44 45 -[[image:image-20241129142314-1.png ||height="352" width="1108"]]44 +[[image:image-20241129142314-1.png]] 46 46 47 47 48 48 == 1.4 Mechinical Drawing == 49 49 50 - ECK1 and ECK10 ECK200 51 51 50 +[[image:image-20240714174241-2.png]] 52 52 53 -[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 54 54 55 - 56 56 == 1.5 Installation == 57 57 58 58 ... ... @@ -127,8 +127,6 @@ 127 127 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 128 128 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 129 129 130 - 131 - 132 132 === 1.7.2 Change address === 133 133 134 134 ... ... @@ -207,8 +207,6 @@ 207 207 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 208 208 209 209 210 -ECK200 211 - 212 212 === 1.7.5 Calibration Method === 213 213 214 214 ... ... @@ -275,9 +275,7 @@ 275 275 276 276 * **Temperature measurement error**: ±0.5°C 277 277 278 -* **Working environment:** 279 -** Ambient Temperature: 0–60°C 280 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 271 +* **Temperature Measure Range**: -20 ~~ 60 °C 281 281 282 282 * **Temperature Accuracy: **±0.5 °C 283 283 ... ... @@ -484,9 +484,7 @@ 484 484 485 485 * **Stability**: ≤2mv/24 hours 486 486 487 -* **Working environment:** 488 -** Ambient Temperature: 0–60°C 489 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 478 +* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 490 490 491 491 * **IP Rated**: IP68 492 492 ... ... @@ -657,11 +657,11 @@ 657 657 == 4.1 Specification == 658 658 659 659 660 -* **Measuring range**: 0-20mg/L, 0 –50℃649 +* **Measuring range**: 0-20mg/L, 0-50°C 661 661 662 -* **Accuracy**: 3%, ±0.5 ℃651 +* **Accuracy**: 3%, ±0.5°C 663 663 664 -* **Resolution**: 0.01 mg/L, 0.01 ℃653 +* **Resolution**: 0.01 mg/L, 0.01°C 665 665 666 666 * **Maximum operating pressure**: 6 bar 667 667 ... ... @@ -669,9 +669,7 @@ 669 669 670 670 * **Power supply voltage**: 5-24V DC 671 671 672 -* **Working environment:** 673 -** Ambient Temperature: 0–60°C 674 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 661 +* **Working environment**: temperature 0-60°C; humidity <95%RH 675 675 676 676 * **Power consumption**: ≤0.5W 677 677 ... ... @@ -794,13 +794,11 @@ 794 794 795 795 * **Stability**: ≤3mV/24 hours 796 796 797 -* **Output signal**: RS485 (standard Modbus-RTU protocol, device default address: 01) 784 +* **Output signal**: A: 420 mA (current loop)B: RS485 (standard Modbus-RTU protocol, device default address: 01) 798 798 799 -* **Power supply voltage**: 5 ~~24V DC (when output signal is RS485),12~~24V DC (when output signal is 4~~20mA)786 +* **Power supply voltage**: 524V DC (when output signal is RS485)1224V DC (when output signal is 420mA) 800 800 801 -* **Working environment:** 802 -** Ambient Temperature: 0–60°C 803 -** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 788 +* **Working environment**: temperature 060°C; humidity ≤ 95%RH 804 804 805 805 * **Power consumption**: ≤ 0.5W 806 806 ... ... @@ -895,3 +895,4 @@ 895 895 896 896 897 897 * **[[Water Quality Sensor Transmitter Datasheet>>https://www.dropbox.com/scl/fi/9tofocmgapkbddshznumn/Datasheet_WQS-xB-WQS-xS_Water-Quality-Sensor-Transmitter.pdf?rlkey=wxua12ur9swk30rkqnh2boo9z&st=axga6epf&dl=0]]** 883 +
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.karry - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.4 KB - Content