Changes for page Water Quality Sensors
Last modified by Karry Zhuang on 2025/07/18 16:37
From version 59.1
edited by Karry Zhuang
on 2025/02/18 15:43
on 2025/02/18 15:43
Change comment:
There is no comment for this version
To version 61.2
edited by Karry Zhuang
on 2025/07/15 15:50
on 2025/07/15 15:50
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -21,6 +21,7 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 +** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 * **Temperature Accuracy: **±0.5 °C ... ... @@ -27,6 +27,7 @@ 27 27 * **Working environment:** 28 28 ** Ambient Temperature: 0–60°C 29 29 ** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 +** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 30 30 * **IP Rated**: IP68 31 31 32 32 * **Max Pressure**: 0.6MPa ... ... @@ -45,10 +45,12 @@ 45 45 46 46 == 1.4 Mechinical Drawing == 47 47 50 + ECK1 and ECK10 ECK200 48 48 49 -[[image:image-20240714174241-2.png]] 50 50 53 +[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 51 51 55 + 52 52 == 1.5 Installation == 53 53 54 54 ... ... @@ -123,6 +123,8 @@ 123 123 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 124 124 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 125 125 130 + 131 + 126 126 === 1.7.2 Change address === 127 127 128 128 ... ... @@ -201,8 +201,11 @@ 201 201 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 202 202 203 203 210 +ECK200 211 + 204 204 === 1.7.5 Calibration Method === 205 205 214 +ECK1 and ECK10.0 206 206 207 207 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. 208 208 ... ... @@ -246,6 +246,11 @@ 246 246 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 247 247 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 248 248 258 + 259 + 260 +ECK200.0 261 + 262 + 249 249 = 2. DR-PH01 Water PH Sensor = 250 250 251 251 == 2.1 Specification ==
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.4 KB - Content