... ... @@ -21,9 +21,14 @@ 21 21 ** **ECK0.1**: 0.2 ~~ 200.0 μS/cm 22 22 ** **ECK1.0** : 0 ~~ 2,000 μS/cm Resolution: 1 μS/cm 23 23 ** **ECK10.0** : 10 ~~ 20,000 μS/cm Resolution: 10 μS/cm 24 +** **ECK200.0** : 1 ~~ 200,000 μS/cm Resolution: 1 μS/cm 24 24 25 25 * **EC Accuracy**: ±1% FS 26 26 * **Temperature Accuracy: **±0.5 °C 28 +* **Working environment:** 29 +** Ambient Temperature: 0–60°C 30 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 31 +** ECK200.0 Continuous monitoring of cross-section water quality, aquaculture, sewage treatment, environmental protection, pharmaceuticals, food, tap water, seawater and other high conductivity environments 27 27 * **IP Rated**: IP68 28 28 29 29 * **Max Pressure**: 0.6MPa ... ... @@ -42,10 +42,12 @@ 42 42 43 43 == 1.4 Mechinical Drawing == 44 44 50 + ECK1 and ECK10 ECK200 45 45 46 -[[image:image-20240714174241-2.png]] 47 47 53 +[[image:image-20240714174241-2.png]] [[image:1752564223905-283.png||height="399" width="160"]] 48 48 55 + 49 49 == 1.5 Installation == 50 50 51 51 ... ... @@ -120,6 +120,8 @@ 120 120 |=(% style="width: 100px;background-color:#4F81BD;color:white" %)New address|=(% style="width: 110px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 106px; background-color: rgb(79, 129, 189); color: white;" %)Data length|=(% style="width: 93px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 low|=(% style="width: 104px; background-color: rgb(79, 129, 189); color: white;" %)CRC16 high 121 121 |(% style="width:99px" %)0X01|(% style="width:112px" %)0X03|(% style="width:106px" %)0X00|(% style="width:93px" %)0X20|(% style="width:104px" %)0XF0 122 122 130 + 131 + 123 123 === 1.7.2 Change address === 124 124 125 125 ... ... @@ -198,8 +198,11 @@ 198 198 **For example**, the returned data is 12 03 04 (% style="color:red" %)**02 AE**(%%) 01 64 B8 D0. 02 AE is converted to decimal 686, K=1, EC: 686uS/cm,temperature: 35.6℃ Convert the returned data to decimal and divide by 10. 199 199 200 200 210 +ECK200 211 + 201 201 === 1.7.5 Calibration Method === 202 202 214 +ECK1 and ECK10.0 203 203 204 204 This device uses one-point calibration, and you need to prepare a known E standard solution. When mileage K=1, 1~~2000 uses 1413μS/cm standard solution, and when mileage K=10, 10~~20000 uses 12.88mS/cm standard solution. 205 205 ... ... @@ -243,6 +243,11 @@ 243 243 |=(% style="width: 42px;background-color:#4F81BD;color:white" %)Address|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Function code|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address high|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Address low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)Quantity high|=(% style="width: 68px; background-color: rgb(79, 129, 189); color: white;" %)Quantity low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 low|=(% style="width: 68px;background-color:#4F81BD;color:white" %)CRC16 high 244 244 |(% style="width:99px" %)0X11|(% style="width:112px" %)0X06|(% style="width:135px" %)0X00|(% style="width:126px" %)0X26|(% style="width:85px" %)0X00|(% style="width:1px" %)0X02|(% style="width:1px" %)0XEB|(% style="width:1px" %)0X50 245 245 258 + 259 + 260 +ECK200.0 261 + 262 + 246 246 = 2. DR-PH01 Water PH Sensor = 247 247 248 248 == 2.1 Specification == ... ... @@ -264,7 +264,9 @@ 264 264 265 265 * **Temperature measurement error**: ±0.5°C 266 266 267 -* **Temperature Measure Range**: -20 ~~ 60 °C 284 +* **Working environment:** 285 +** Ambient Temperature: 0–60°C 286 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 268 268 269 269 * **Temperature Accuracy: **±0.5 °C 270 270 ... ... @@ -471,7 +471,9 @@ 471 471 472 472 * **Stability**: ≤2mv/24 hours 473 473 474 -* **Equipment working conditions**: Ambient temperature: 0-60°C Relative humidity: <85%RH 493 +* **Working environment:** 494 +** Ambient Temperature: 0–60°C 495 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 475 475 476 476 * **IP Rated**: IP68 477 477 ... ... @@ -654,7 +654,9 @@ 654 654 655 655 * **Power supply voltage**: 5-24V DC 656 656 657 -* **Working environment**: temperature 0-60°C; humidity <95%RH 678 +* **Working environment:** 679 +** Ambient Temperature: 0–60°C 680 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 658 658 659 659 * **Power consumption**: ≤0.5W 660 660 ... ... @@ -781,7 +781,9 @@ 781 781 782 782 * **Power supply voltage**: 5~~24V DC (when output signal is RS485), 12~~24V DC (when output signal is 4~~20mA) 783 783 784 -* **Working environment**: temperature 060°C; humidity ≤ 95%RH 807 +* **Working environment:** 808 +** Ambient Temperature: 0–60°C 809 +** Relative Humidity: <85% RH(Specifically refers to the cable male and female) 785 785 786 786 * **Power consumption**: ≤ 0.5W 787 787
- 1752564223905-283.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.karry - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.4 KB - Content