Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,19 +16,19 @@ 16 16 == 1.1 What is DDS20-NB NB-IoT Ultrasonic liquid level Sensor == 17 17 18 18 19 -The Dragino DDS20-NB is a **NB-IoT Ultrasonic liquid level sensor** for Internet of Things solution. It uses **none-contact method **to measure the **height of liquid** in a container without opening the container, and send IoT platform via NB-IoT network. 19 +The Dragino DDS20-NB is a (% style="color:blue" %)**NB-IoT Ultrasonic liquid level sensor**(%%) for Internet of Things solution. It uses (% style="color:blue" %)**none-contact method **(%%)to measure the (% style="color:blue" %)**height of liquid**(%%) in a container without opening the container, and send IoT platform via NB-IoT network. 20 20 21 21 The DDS20-NB sensor is installed directly below the container to detect the height of the liquid level. User doesn't need to open a hole on the container to be tested. The none-contact measurement makes the measurement safety, easier and possible for some strict situation. 22 22 23 -DDS20-NB uses **ultrasonic sensing technology** for distance measurement. DDS20-NB is of high accuracy to measure various liquid such as: **toxic substances**, **strong acids**, **strong alkalis** and **various pure liquids** in high-temperature and high-pressure airtight containers. 23 +DDS20-NB uses (% style="color:blue" %)**ultrasonic sensing technology**(%%) for distance measurement. DDS20-NB is of high accuracy to measure various liquid such as: (% style="color:blue" %)**toxic substances**, **strong acids**, **strong alkalis**(%%) and (% style="color:blue" %)**various pure liquids**(%%) in high-temperature and high-pressure airtight containers. 24 24 25 - PS-NB-NAsupports different uplink methods including **MQTT, MQTTs, UDP & TCP** for different application requirement, and support uplinks to various IoT Servers.25 +DDS20-NB supports different uplink methods including (% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%) for different application requirement, and support uplinks to various IoT Servers. 26 26 27 - PS-NB-NA**supports BLE configure **and** OTA update** which make user easy to use.27 +DDS20-NB (% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%) which make user easy to use. 28 28 29 - PS-NB-NAis powered by **8500mAh Li-SOCI2 battery**, it is designed for long-term use up to severa years.29 +DDS20-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long-term use up to severa years. 30 30 31 - PS-NB-NAhas optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration.31 +DDS20-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration. 32 32 33 33 34 34 [[image:image-20230911140426-2.png||height="320" width="951"]] ... ... @@ -295,8 +295,25 @@ 295 295 (% style="display:none" %) 296 296 297 297 298 -= 2.Use S31-NB tocommunicatewith IoT Server=298 +== 1.12 Mechanical == 299 299 300 + 301 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143884058-338.png?rev=1.1||alt="1675143884058-338.png"]] 302 + 303 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143899218-599.png?rev=1.1||alt="1675143899218-599.png"]] 304 + 305 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143909447-639.png?rev=1.1||alt="1675143909447-639.png"]] 306 + 307 + 308 +(% style="color:blue" %)**Probe Mechanical:** 309 + 310 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-1.png?rev=1.1||alt="image-20220615090910-1.png"]] 311 + 312 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-2.png?rev=1.1||alt="image-20220615090910-2.png"]] 313 + 314 + 315 += 2. Use DDS20-NB to communicate with IoT Server = 316 + 300 300 == 2.1 Send data to IoT server via NB-IoT network == 301 301 302 302 ... ... @@ -396,7 +396,7 @@ 396 396 397 397 These bytes include the hardware and software version. 398 398 399 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x00 for S 31B-NB& S31-NB416 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x00 for DDS20-NB 400 400 401 401 (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 100 402 402 ... ... @@ -423,20 +423,6 @@ 423 423 **99** Not known or not detectable 424 424 425 425 426 -(% style="color:blue" %)**Temperature: ** 427 - 428 -If payload is: 0105H: (0105 & 8000 == 0), temp = 0105H /10 = 26.1 degree 429 - 430 -If payload is: FF3FH : (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 431 - 432 -(FF3F & 8000: Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 433 - 434 - 435 -(% style="color:blue" %)**Humidity: ** 436 - 437 -Read:0295(H)=661(D) Value: 661 / 10=66.1, So 66.1% 438 - 439 - 440 440 (% style="color:blue" %)**TimeStamp: ** 441 441 442 442 Unit TimeStamp Example: 64d49439(H) = 1691653177(D) ... ... @@ -463,61 +463,123 @@ 463 463 464 464 (% style="color:#4472c4" %)**field1=27.9&field2=49.9&field3=3.23&field4=28** 465 465 469 +== 2.3 Uplink Payload == 466 466 467 -== 2.3 Test Uplink and Change Update Interval == 468 468 472 +((( 473 +DDS20-NB will uplink payload via LoRaWAN with below payload format: 474 +))) 469 469 470 -By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8 476 +((( 477 +Uplink payload includes in total 8 bytes. 478 +))) 471 471 472 -User can use below commands to change the (% style="color:blue" %)**uplink interval**. 480 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 481 +|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1 482 +|(% style="width:95px" %)Value|(% style="width:61px" %)[[BAT>>||anchor="H2.3.2A0BatteryInfo"]]|((( 483 +[[Distance>>||anchor="H2.3.3A0Distance"]] 484 +(unit: mm) 485 +)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.4A0InterruptPin"]]|((( 486 +[[Temperature (Optional)>>||anchor="H2.3.5A0DS18B20Temperaturesensor"]] 487 +)))|[[Sensor Flag>>||anchor="H2.3.6A0SensorFlag"]] 473 473 474 - (% style="color:#037691"%)**AT+TDC=600** (%%) ~/~/SetUpdateIntervalo 600s489 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/%E5%BE%AE%E4%BF%A1%E6%88%AA%E5%9B%BE_20230702135733.png?width=964&height=215&rev=1.1||alt="微信截图_20230702135733.png"]] 475 475 476 -User can also push the button for more than 1 seconds to activate an uplink. 477 477 492 +=== 2.3.1 Battery Info === 478 478 479 -== 2.4 Multi-Samplings and One uplink == 480 480 495 +Check the battery voltage for DDS20-NB. 481 481 482 - To save battery life, S31-NBwill sample temperature & humidity data every 15minutesand send one uplink every2hours. So each uplink it will include8stored data + 1 real-time data. They are defined by:497 +Ex1: 0x0B45 = 2885mV 483 483 484 - * (% style="color:#037691"%)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every900seconds(15 minutes, the minimum can be set to 180 seconds)499 +Ex2: 0x0B49 = 2889mV 485 485 486 -* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 487 487 488 - Thediagrambelow explainshe relationship between TR, NOUD, and TDC moreclearly:502 +=== 2.3.2 Distance === 489 489 490 -[[image:1692424376354-959.png]] 491 491 505 +((( 506 +Get the distance. Flat object range 20mm - 2000mm. 507 +))) 492 492 493 -== 2.5 Humidity and Temperature alarm function == 509 +((( 510 +For example, if the data you get from the register is **0x06 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 494 494 512 +(% style="color:blue" %)**0605(H) = 1541 (D) = 1541 mm.** 513 +))) 495 495 496 - Oneach sampling defineby AT+TR ( default900sor 15 minutes),when thevalueexceedherange, itwilltriggeranAlarm andimmediatelysendsa uplink.515 +* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 497 497 517 +* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid. 498 498 499 - (%style="color:blue"%)**AT Commands:**519 +=== 2.3.3 Interrupt Pin === 500 500 501 -(% style="color:#037691" %)**AT+ SHHUM=min,max** 502 502 503 - Example: AT+ SHHUM=50,80 ~/~/ Alarm when humiditylowerthan50orhigherhan80.522 +This data field shows if this packet is generated by interrupt or not. 504 504 524 +**Example:** 505 505 506 - (%style="color:#037691" %)**AT+ SHTEMP=min,max**526 +0x00: Normal uplink packet. 507 507 508 - Example:AT+ SHTEMP=20,30 ~/~/ Alarm whenmperaturelower than20 or higherthan 30528 +0x01: Interrupt Uplink Packet. 509 509 510 510 511 - (%style="color:red"%)**Notice:**531 +=== 2.3.4 DS18B20 Temperature sensor === 512 512 513 -* To disable Alarm, user can set min and max to same value , such as (% style="color:#037691" %)**AT+SHTEMP=0,0.** 514 514 515 - * If useronly want tosendonly minor max, user canset thearmtoavaluethatdevice won’treach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.**534 +This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature. 516 516 536 +**Example**: 537 + 538 +If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 539 + 540 +If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 541 + 542 + 543 +=== 2.3.5 Sensor Flag === 544 + 545 + 546 +((( 547 +0x01: Detect Ultrasonic Sensor 548 +))) 549 + 550 +((( 551 +0x00: No Ultrasonic Sensor 552 + 553 + 554 +))) 555 + 556 +== 2.4 Test Uplink and Change Update Interval == 557 + 558 + 559 +By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8 560 + 561 +User can use below commands to change the (% style="color:blue" %)**uplink interval**. 562 + 563 +(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s 564 + 565 +User can also push the button for more than 1 seconds to activate an uplink. 566 + 567 + 568 +== 2.5 Multi-Samplings and One uplink == 569 + 570 + 571 +To save battery life, DDS20-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 572 + 573 +* (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 574 + 575 +* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 576 + 577 +The diagram below explains the relationship between TR, NOUD, and TDC more clearly: 578 + 579 +[[image:1692424376354-959.png]] 580 + 581 + 517 517 == 2.6 Trggier an uplink by external interrupt == 518 518 519 519 520 -S 31-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.585 +DDS20-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets. 521 521 522 522 (% style="color:blue" %)**AT command:** 523 523 ... ... @@ -531,12 +531,12 @@ 531 531 532 532 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 533 533 534 -= 3. Configure S 31x-NB =599 += 3. Configure DDS20-NB = 535 535 536 536 == 3.1 Configure Methods == 537 537 538 538 539 -S 31x-NB supports below configure method:604 +DDS20-NB supports below configure method: 540 540 541 541 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 542 542 ... ... @@ -625,7 +625,7 @@ 625 625 = 4. Battery & Power Consumption = 626 626 627 627 628 -S 31x-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.693 +DDS20-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 629 629 630 630 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 631 631 ... ... @@ -657,11 +657,22 @@ 657 657 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 658 658 659 659 660 -= 7. OrderInfo =725 += 7. Trouble Shooting = 661 661 727 +== 7.1 Why i always see 0x0000 or 0 for the distance value? == 662 662 663 -Part Number: (% style="color:blue" %)**S31-NB-XX / S31B-NB-XX** 664 664 730 +((( 731 +DDS20-NB has a strict [[**installation requirement**>>||anchor="H1.5A0InstallDDS20-NB"]]. Please make sure the installation method exactly follows up with the installation requirement. Otherwise, the reading might be always 0x00. 732 + 733 +If you have followed the instruction requirement exactly but still see the 0x00 reading issue, please. please double-check the decoder, you can check the raw payload to verify. 734 +))) 735 + 736 += 8. Order Info = 737 + 738 + 739 +Part Number: (% style="color:blue" %)**DDS20-NB-XX** 740 + 665 665 (% style="color:red" %)**XX**(%%): 666 666 667 667 * (% style="color:#037691" %)**GE**(%%): General version ( Exclude SIM card) ... ... @@ -671,12 +671,12 @@ 671 671 (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 672 672 673 673 674 -= 8. Packing Info =750 += 9. Packing Info = 675 675 676 676 677 677 (% style="color:#037691" %)**Package Includes**: 678 678 679 -* S 31-NBor S31-NBNB-IoTSensorNode x 1755 +* DDS20-NB NB-IoT Ultrasonic liquid level sensor x 1 680 680 681 681 * External antenna x 1 682 682 ... ... @@ -690,7 +690,7 @@ 690 690 691 691 * Weight / pcs : 180g 692 692 693 -= 9. Support =769 += 10. Support = 694 694 695 695 696 696 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.