Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -DDS20-NB --NB-IoT1 +DDS20-NB_NB-IoT_Ultrasonic_Liquid_Level_Sensor_User_Manual - Content
-
... ... @@ -1,7 +1,8 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20230911 134259-1.png||height="570" width="570"]]2 +[[image:image-20230819102136-3.png]] 3 3 4 4 5 + 5 5 **Table of Contents:** 6 6 7 7 {{toc/}} ... ... @@ -13,52 +13,61 @@ 13 13 14 14 = 1. Introduction = 15 15 16 -== 1.1 What is DDS20-NB NB-IoTUltrasonicliquidlevelSensor ==17 +== 1.1 What is S31x-NB NB-IoT Temperature & Humidity Sensor == 17 17 18 18 19 -The Dragino DDS20-NBisaUltrasonicliquidlevel sensor**s **none-contact method**to measure the**heightofliquid**containerwithoutopening thecontainer, andsendIoTplatformvia NB-IoT network.20 +The Dragino S31-NB and S31B-NB are (% style="color:blue" %)**NB-IoT Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the surrounding (% style="color:blue" %)**environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via NB-IoT network*. 20 20 21 -The DDS20-NBsensoris installeddirectlybelowthecontainertodetecttheheight oftheliquidlevel.Userdoesn'tneedtoopenaholeonhecontainertobetested.Thenone-contactmeasurementmakesthemeasurementfety,easier andpossibleforsomestrictsituation.22 +The temperature & humidity sensor used in S31-NB is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing**(%%) for long term use. 22 22 23 - DDS20-NBuses **ultrasonicsensing technology** fordistancemeasurement.DDS20-NBisof high accuracy tomeasure variousliquidsuchas: **toxicsubstances**,strongacids**, **strongalkalis**and **variouspureliquids** in high-temperatureandhigh-pressureairtightcontainers.24 +S31-NB supports different uplink methods include (% style="color:blue" %)**TCP, MQTT, UDP**(%%) for different application requirement. and Support Uplinks to various IoT Servers. 24 24 25 - PS-NB-NAsupportsdifferentuplinkmethods including**MQTT,MQTTs,UDP& TCP** fordifferentapplicationrequirement,andsupportuplinkstovariousIoTServers.26 +S31-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to several years. (Real-world battery life depends on the use environment, update period and uplink method. Please check related Power Analyze report). 26 26 27 - PS-NB-NA**supportsBLE configure**and** OTA update** which makeusereasytouse.28 +*make sure you have NB-IoT coverage locally. 28 28 29 -PS-NB-NA is powered by **8500mAh Li-SOCI2 battery**, it is designed for long-term use up to severa years. 30 30 31 - PS-NB-NA has optional built-in SIM card and default IoT server connection version. Whichmakes it works with simple configuration.31 +[[image:1692411831805-116.png]] 32 32 33 33 34 -[[image:image-20230911140426-2.png||height="320" width="951"]] 35 - 36 - 37 37 == 1.2 Features == 38 38 39 39 40 40 * NB-IoT Bands: B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 @H-FDD 41 41 * Ultra-low power consumption 42 -* Liquid Level Measurement by Ultrasonic technology 43 -* Measure through container, No need to contact Liquid 44 -* Valid level range 20mm - 2000mm 45 -* Accuracy: ±(5mm+S*0.5%) (S: Measure Value) 39 +* External 3 meters SHT31 probe (For S31-NB) 40 +* Measure range -40°C ~~ 85°C 41 +* Temperature & Humidity alarm 46 46 * Multiply Sampling and one uplink 47 47 * Support Bluetooth v5.1 remote configure and update firmware 48 48 * Uplink on periodically 49 49 * Downlink to change configure 50 -* IP66 Waterproof Enclosure 51 51 * 8500mAh Battery for long term use 52 52 * Nano SIM card slot for NB-IoT SIM 53 53 49 + 54 54 == 1.3 Specification == 55 55 56 56 57 57 (% style="color:blue" %)**Common DC Characteristics:** 58 58 59 -* Supply Voltage: 2. 5v ~~ 3.6v55 +* Supply Voltage: 2.1v ~~ 3.6v 60 60 * Operating Temperature: -40 ~~ 85°C 61 61 58 +(% style="color:blue" %)**Temperature Sensor:** 59 + 60 +* Range: -40 to + 80°C 61 +* Accuracy: ±0.2 @ 0-90 °C 62 +* Resolution: 0.1°C 63 +* Long Term Shift: <0.03 °C/yr 64 + 65 +(% style="color:blue" %)**Humidity Sensor: ** 66 + 67 +* Range: 0 ~~ 99.9% RH 68 +* Accuracy: ± 2%RH ( 0 ~~ 100%RH) 69 +* Resolution: 0.01% RH 70 +* Long Term Shift: <0.25 %RH/yr 71 + 62 62 (% style="color:blue" %)**NB-IoT Spec:** 63 63 64 64 (% style="color:#037691" %)**NB-IoT Module: BC660K-GL** ... ... @@ -96,6 +96,7 @@ 96 96 * STOP Mode: 10uA @ 3.3v 97 97 * Max transmit power: 350mA@3.3v 98 98 109 + 99 99 == 1.4 Applications == 100 100 101 101 ... ... @@ -106,6 +106,7 @@ 106 106 * Smart Cities 107 107 * Smart Factory 108 108 120 + 109 109 == 1.5 Sleep mode and working mode == 110 110 111 111 ... ... @@ -133,6 +133,7 @@ 133 133 ))) 134 134 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 135 135 148 + 136 136 == 1.7 BLE connection == 137 137 138 138 ... ... @@ -295,6 +295,7 @@ 295 295 296 296 * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time. 297 297 311 + 298 298 === 2.2.2 HEX format Payload(Type~=0) === 299 299 300 300 ... ... @@ -427,6 +427,7 @@ 427 427 428 428 * If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.** 429 429 444 + 430 430 == 2.6 Trggier an uplink by external interrupt == 431 431 432 432 ... ... @@ -444,6 +444,7 @@ 444 444 445 445 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 446 446 462 + 447 447 = 3. Configure S31x-NB = 448 448 449 449 == 3.1 Configure Methods == ... ... @@ -455,6 +455,7 @@ 455 455 456 456 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 457 457 474 + 458 458 == 3.2 AT Commands Set == 459 459 460 460 ... ... @@ -560,6 +560,7 @@ 560 560 561 561 * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 562 562 580 + 563 563 = 6. FAQ = 564 564 565 565 == 6.1 How can I access t BC660K-GL AT Commands? == ... ... @@ -603,6 +603,7 @@ 603 603 604 604 * Weight / pcs : 180g 605 605 624 + 606 606 = 9. Support = 607 607 608 608
- image-20230911140426-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -121.6 KB - Content