... ... @@ -16,21 +16,17 @@
16 16  == 1.1 What is DDS20-NB NB-IoT Ultrasonic liquid level Sensor ==
17 17  
18 18  
19 -The Dragino DDS20-NB is a (% style="color:blue" %)**NB-IoT Ultrasonic liquid level sensor**(%%) for Internet of Things solution. It uses (% style="color:blue" %)**none-contact method **(%%)to measure the (% style="color:blue" %)**height of liquid**(%%) in a container without opening the container, and send IoT platform via NB-IoT network.
19 +The Dragino S31-NB and S31B-NB are (% style="color:blue" %)**NB-IoT Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the surrounding (% style="color:blue" %)**environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via NB-IoT network*.
20 20  
21 -The DDS20-NB sensor is installed directly below the container to detect the height of the liquid level. User doesn't need to open a hole on the container to be tested. The none-contact measurement makes the measurement safety, easier and possible for some strict situation. 
21 +The temperature & humidity sensor used in S31-NB is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing**(%%) for long term use.
22 22  
23 -DDS20-NB uses (% style="color:blue" %)**ultrasonic sensing technology**(%%) for distance measurement. DDS20-NB is of high accuracy to measure various liquid such as: (% style="color:blue" %)**toxic substances**, **strong acids**, **strong alkalis**(%%) and (% style="color:blue" %)**various pure liquids**(%%) in high-temperature and high-pressure airtight containers.
23 +S31-NB supports different uplink methods include (% style="color:blue" %)**TCP, MQTT, UDP**(%%) for different application requirement. and Support Uplinks to various IoT Servers.
24 24  
25 -DDS20-NB supports different uplink methods including (% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%) for different application requirement, and support uplinks to various IoT Servers.
25 +S31-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to several years. (Real-world battery life depends on the use environment, update period and uplink method. Please check related Power Analyze report).
26 26  
27 -DDS20-NB (% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%) which make user easy to use.
27 +*make sure you have NB-IoT coverage locally.
28 28  
29 -DDS20-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long-term use up to severa years.
30 30  
31 -DDS20-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration.
32 -
33 -
34 34  [[image:image-20230911140426-2.png||height="320" width="951"]]
35 35  
36 36  
... ... @@ -39,15 +39,13 @@
39 39  
40 40  * NB-IoT Bands: B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 @H-FDD
41 41  * Ultra-low power consumption
42 -* Liquid Level Measurement by Ultrasonic technology
43 -* Measure through container, No need to contact Liquid
44 -* Valid level range 20mm - 2000mm
45 -* Accuracy: ±(5mm+S*0.5%) (S: Measure Value)
38 +* External 3 meters SHT31 probe (For S31-NB)
39 +* Measure range -40°C ~~ 85°C
40 +* Temperature & Humidity alarm
46 46  * Multiply Sampling and one uplink
47 47  * Support Bluetooth v5.1 remote configure and update firmware
48 48  * Uplink on periodically
49 49  * Downlink to change configure
50 -* IP66 Waterproof Enclosure
51 51  * 8500mAh Battery for long term use
52 52  * Nano SIM card slot for NB-IoT SIM
53 53  
... ... @@ -56,9 +56,23 @@
56 56  
57 57  (% style="color:blue" %)**Common DC Characteristics:**
58 58  
59 -* Supply Voltage: 2.5v ~~ 3.6v
53 +* Supply Voltage: 2.1v ~~ 3.6v
60 60  * Operating Temperature: -40 ~~ 85°C
61 61  
56 +(% style="color:blue" %)**Temperature Sensor:**
57 +
58 +* Range: -40 to + 80°C
59 +* Accuracy: ±0.2 @ 0-90 °C
60 +* Resolution: 0.1°C
61 +* Long Term Shift: <0.03 °C/yr
62 +
63 +(% style="color:blue" %)**Humidity Sensor: **
64 +
65 +* Range: 0 ~~ 99.9% RH
66 +* Accuracy: ± 2%RH ( 0 ~~ 100%RH)
67 +* Resolution: 0.01% RH
68 +* Long Term Shift: <0.25 %RH/yr
69 +
62 62  (% style="color:blue" %)**NB-IoT Spec:**
63 63  
64 64  (% style="color:#037691" %)**NB-IoT Module: BC660K-GL**
... ... @@ -96,144 +96,25 @@
96 96  * STOP Mode: 10uA @ 3.3v
97 97  * Max transmit power: 350mA@3.3v
98 98  
99 -== 1.4 Suitable Container & Liquid ==
107 +== 1.4 Applications ==
100 100  
101 101  
102 -* Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc.
103 -* Container shape is regular, and surface is smooth.
104 -* Container Thickness:
105 -** Pure metal material.  2~~8mm, best is 3~~5mm
106 -** Pure non metal material: <10 mm
107 -* Pure liquid without irregular deposition.
110 +* Smart Buildings & Home Automation
111 +* Logistics and Supply Chain Management
112 +* Smart Metering
113 +* Smart Agriculture
114 +* Smart Cities
115 +* Smart Factory
108 108  
109 -(% style="display:none" %)
117 +== 1.5 Sleep mode and working mode ==
110 110  
111 -== 1.5 Install DDS20-NB ==
112 112  
113 -
114 -(% style="color:blue" %)**Step 1**(%%):  ** Choose the installation point.**
115 -
116 -DDS20-NB (% style="color:red" %)**MUST**(%%) be installed on the container bottom middle position.
117 -
118 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-3.png?rev=1.1||alt="image-20220615091045-3.png"]]
119 -
120 -
121 -(((
122 -(% style="color:blue" %)**Step 2**(%%):  **Polish the installation point.**
123 -)))
124 -
125 -(((
126 -For Metal Surface with paint, it is important to polish the surface, first use crude sand paper to polish the paint level , then use exquisite sand paper to polish the metal level to make it shine & smooth.
127 -)))
128 -
129 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/image-20230613143052-5.png?rev=1.1||alt="image-20230613143052-5.png"]]
130 -
131 -
132 -No polish needed if the container is shine metal surface without paint or non-metal container.
133 -
134 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/image-20230613143125-6.png?rev=1.1||alt="image-20230613143125-6.png"]]
135 -
136 -
137 -(((
138 -(% style="color:blue" %)**Step3:   **(%%)**Test the installation point.**
139 -)))
140 -
141 -(((
142 -Power on DDS20-NB, check if the blue LED is on, If the blue LED is on, means the sensor works. Then put ultrasonic coupling paste on the sensor and put it tightly on the installation point.
143 -)))
144 -
145 -(((
146 -It is necessary to put the coupling paste between the sensor and the container, otherwise DDS20-NB won't detect the liquid level.
147 -)))
148 -
149 -(((
150 -After paste the DDS20-NB well, power on DDS20-NB. In the first 30 seconds of booting, device will check the sensors status and BLUE LED will show the status as below. After 30 seconds, BLUE LED will be off to save battery life.
151 -)))
152 -
153 -
154 -(((
155 -(% style="color:blue" %)**LED Status:**
156 -)))
157 -
158 -* (((
159 -**Onboard LED**: When power on device, the onboard LED will fast blink 4 times which means detect the sensor well.
160 -)))
161 -
162 -* (((
163 -(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** always ON**(%%): Sensor is power on but doesn't detect liquid. There is problem in installation point.
164 -)))
165 -* (((
166 -(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** slowly blinking**(%%): Sensor detects Liquid Level, The installation point is good.
167 -)))
168 -
169 -(((
170 -DDS20-NB will enter into low power mode at 30 seconds after system reset or power on, Blue LED will be off after that.
171 -)))
172 -
173 -
174 -(((
175 -(% style="color:red" %)**Note :**(%%)** (% style="color:blue" %)Ultrasonic coupling paste(%%)**(% style="color:blue" %) (%%) is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally.
176 -)))
177 -
178 -
179 -(((
180 -(% style="color:blue" %)**Step4:   **(%%)**Install use Epoxy ab glue.**
181 -)))
182 -
183 -(((
184 -Prepare Eproxy AB glue.
185 -)))
186 -
187 -(((
188 -Put Eproxy AB glue in the sensor and press it hard on the container installation point.
189 -)))
190 -
191 -(((
192 -Reset DDS20-NB and see if the BLUE LED is slowly blinking.
193 -)))
194 -
195 -[[image:image-20230809172509-1.png]]
196 -
197 -(((
198 -(% style="color:red" %)**Note :**(% style="color:red; display:none" %)** **
199 -
200 -(% style="color:red" %)**1:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** needs 3~~ 5 minutes to stable attached. we can use other glue material to keep it in the position.
201 -)))
202 -
203 -(((
204 -(% style="color:red" %)**2:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally.
205 -)))
206 -
207 -
208 -== 1.6 Applications ==
209 -
210 -
211 -* Smart liquid control solution
212 -
213 -* Smart liquefied gas solution
214 -
215 -== 1.7 Precautions ==
216 -
217 -
218 -* At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights.
219 -
220 -* For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container.
221 -
222 -* When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable.
223 -
224 -(% style="display:none" %)
225 -
226 -
227 -
228 -== 1.8 Sleep mode and working mode ==
229 -
230 -
231 231  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
232 232  
233 233  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
234 234  
235 235  
236 -== 1.9 Button & LEDs ==
125 +== 1.6 Button & LEDs ==
237 237  
238 238  
239 239  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
... ... @@ -252,10 +252,10 @@
252 252  )))
253 253  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
254 254  
255 -== 1.10 BLE connection ==
144 +== 1.7 BLE connection ==
256 256  
257 257  
258 -DDS20-NB support BLE remote configure and firmware update.
147 +S31x-NB support BLE remote configure and firmware update.
259 259  
260 260  
261 261  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
... ... @@ -267,19 +267,21 @@
267 267  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
268 268  
269 269  
270 -== 1.11 Pin Definitions & Switch ==
159 +== 1.8 Pin Definitions & Switch ==
271 271  
272 272  
162 +S31x-NB use the mother board from S31-NB which as below.
163 +
273 273  [[image:image-20230819104805-5.png]]
274 274  
275 275  
276 -=== 1.11.1 Jumper JP2 ===
167 +=== 1.8.1 Jumper JP2 ===
277 277  
278 278  
279 279  Power on Device when put this jumper.
280 280  
281 281  
282 -=== 1.11.2 BOOT MODE / SW1 ===
173 +=== 1.8.2 BOOT MODE / SW1 ===
283 283  
284 284  
285 285  **1)** (% style="color:blue" %)**ISP**(%%): upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run.
... ... @@ -287,48 +287,61 @@
287 287  **2)** (% style="color:blue" %)**Flash**(%%): work mode, device starts to work and send out console output for further debug
288 288  
289 289  
290 -=== 1.11.3 Reset Button ===
181 +=== 1.8.3 Reset Button ===
291 291  
292 292  
293 293  Press to reboot the device.
294 294  
295 -(% style="display:none" %)
296 296  
187 +== 1.9 Hardware Variant ==
297 297  
298 -== 1.12 Mechanical ==
299 299  
190 +(% border="1" cellspacing="5" style="width:410px" %)
191 +|=(% style="width: 102px;background-color:#4F81BD;color:white" %)Model|=(% style="width: 126px; background-color:#4F81BD;color:white" %)Photo|=(% style="width: 179px;background-color:#4F81BD;color:white" %)Probe Info
192 +|(% style="width:102px" %)(((
193 +S31-NB
194 +)))|(% style="width:126px" %)(((
195 +(% style="text-align:center" %)
196 +[[image:image-20230819110632-6.png||height="130" width="104"]]
197 +)))|(% style="width:179px" %)(((
198 +1 x SHT31 Probe
300 300  
301 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143884058-338.png?rev=1.1||alt="1675143884058-338.png"]]
200 +Cable Length : 3 meters
302 302  
303 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143899218-599.png?rev=1.1||alt="1675143899218-599.png"]]
202 +
203 +)))
204 +|(% style="width:102px" %)(((
205 +S31B-NB
206 +)))|(% style="width:126px" %)(((
207 +(% style="text-align:center" %)
208 +[[image:image-20230819110702-7.png||height="164" width="90"]]
209 +)))|(% style="width:179px" %)(((
210 +1 x SHT31 Probe
304 304  
305 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143909447-639.png?rev=1.1||alt="1675143909447-639.png"]]
212 +Installed in device.
213 +)))
306 306  
215 +(% style="display:none" %)
307 307  
308 -(% style="color:blue" %)**Probe Mechanical:**
309 309  
310 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-1.png?rev=1.1||alt="image-20220615090910-1.png"]]
311 311  
312 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-2.png?rev=1.1||alt="image-20220615090910-2.png"]]
219 += 2. Use S31-NB to communicate with IoT Server =
313 313  
314 -
315 -= 2. Use DDS20-NB to communicate with IoT Server =
316 -
317 317  == 2.1 Send data to IoT server via NB-IoT network ==
318 318  
319 319  
320 -The DDS20-NB is equipped with a NB-IoT module, the pre-loaded firmware in DDS20-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by DDS20-NB.
224 +The S31-NB is equipped with a NB-IoT module, the pre-loaded firmware in S31-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by S31-NB.
321 321  
322 322  
323 323  Below shows the network structure:
324 324  
325 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-NB_NB-IoT_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/image-20230911140426-2.png?width=951&height=320&rev=1.1||alt="image-20230911140426-2.png"]]
229 +[[image:1692415924540-357.png]]
326 326  
327 327  
328 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DDS20-NB.
232 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of S31-NB.
329 329  
330 330  
331 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DDS20-NB send data to IoT server.
235 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set S31-NB send data to IoT server.
332 332  
333 333  * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]].
334 334  
... ... @@ -358,13 +358,13 @@
358 358  [[image:image-20230819113244-11.png||height="141" width="367"]]
359 359  )))|(% style="width:170px" %)
360 360  
361 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DDS20-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].
265 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate S31-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].
362 362  
363 363  
364 364  == 2.2 ​Payload Types ==
365 365  
366 366  
367 -To meet different server requirement, DDS20-NB supports different payload type.
271 +To meet different server requirement, S31-NB supports different payload type.
368 368  
369 369  **Includes:**
370 370  
... ... @@ -390,7 +390,7 @@
390 390  
391 391  This is the General Json Format. As below:
392 392  
393 -(% style="color:#4472c4" %)**{"IMEI":866207053462762,"temperature":29.2,"humidity":54.2,"battery":3.27,"signal":24,"Model":DDS20-NB, "1":{28.2,48.3,2023/08/10 08:00:37},"2":{28.1,49.1,2023/08/10 07:57:37},"3":{28.1,48.5,2023/08/10 07:54:37},"4":{28.2,48.6,2023/08/10 07:51:37},"5":{28.1,48.9,2023/08/10 07:48:37},"6":{28.2,48.8,2023/08/10 07:45:37},"7":{28.2,48.8,2023/08/10 07:42:37},"8":{28.0,48.8,2023/08/10 07:39:37}}**
297 +(% style="color:#4472c4" %)**{"IMEI":866207053462762,"temperature":29.2,"humidity":54.2,"battery":3.27,"signal":24,"Model":S31x-NB, "1":{28.2,48.3,2023/08/10 08:00:37},"2":{28.1,49.1,2023/08/10 07:57:37},"3":{28.1,48.5,2023/08/10 07:54:37},"4":{28.2,48.6,2023/08/10 07:51:37},"5":{28.1,48.9,2023/08/10 07:48:37},"6":{28.2,48.8,2023/08/10 07:45:37},"7":{28.2,48.8,2023/08/10 07:42:37},"8":{28.0,48.8,2023/08/10 07:39:37}}**
394 394  
395 395  
396 396  (% style="color:red" %)**Notice, from above payload:**
... ... @@ -413,7 +413,7 @@
413 413  
414 414  These bytes include the hardware and software version.
415 415  
416 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x00 for DDS20-NB
320 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x00 for S31B-NB & S31-NB
417 417  
418 418  (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 100
419 419  
... ... @@ -440,6 +440,20 @@
440 440  **99**    Not known or not detectable
441 441  
442 442  
347 +(% style="color:blue" %)**Temperature: **
348 +
349 +If payload is: 0105H:  (0105 & 8000 == 0), temp = 0105H /10 = 26.1 degree
350 +
351 +If payload is: FF3FH :  (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
352 +
353 +(FF3F & 8000: Judge whether the highest bit is 1, when the highest bit is 1, it is negative)
354 +
355 +
356 +(% style="color:blue" %)**Humidity:   **
357 +
358 +Read:0295(H)=661(D)    Value:  661 / 10=66.1, So 66.1%
359 +
360 +
443 443  (% style="color:blue" %)**TimeStamp:   **
444 444  
445 445  Unit TimeStamp Example: 64d49439(H) = 1691653177(D)
... ... @@ -466,123 +466,61 @@
466 466  
467 467  (% style="color:#4472c4" %)**field1=27.9&field2=49.9&field3=3.23&field4=28**
468 468  
469 -== 2.3  ​Uplink Payload ==
470 470  
388 +== 2.3 Test Uplink and Change Update Interval ==
471 471  
472 -(((
473 -DDS20-NB will uplink payload via LoRaWAN with below payload format: 
474 -)))
475 475  
476 -(((
477 -Uplink payload includes in total 8 bytes.
478 -)))
391 +By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8
479 479  
480 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
481 -|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1
482 -|(% style="width:95px" %)Value|(% style="width:61px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
483 -[[Distance>>||anchor="H2.3.2A0Distance"]]
484 -(unit: mm)
485 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
486 -[[Temperature (Optional)>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
487 -)))|[[Sensor Flag>>||anchor="H2.3.5A0SensorFlag"]]
393 +User can use below commands to change the (% style="color:blue" %)**uplink interval**.
488 488  
489 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/%E5%BE%AE%E4%BF%A1%E6%88%AA%E5%9B%BE_20230702135733.png?width=964&height=215&rev=1.1||alt="微信截图_20230702135733.png"]]
395 +(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s
490 490  
397 +User can also push the button for more than 1 seconds to activate an uplink.
491 491  
492 -=== 2.3.1  Battery Info ===
493 493  
400 +== 2.4 Multi-Samplings and One uplink ==
494 494  
495 -Check the battery voltage for DDS20-NB.
496 496  
497 -Ex1: 0x0B45 = 2885mV
403 +To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
498 498  
499 -Ex2: 0x0B49 = 2889mV
405 +* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
500 500  
407 +* (% style="color:#037691" %)**AT+NOUD=8**     (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
501 501  
502 -=== 2.3.2  Distance ===
409 +The diagram below explains the relationship between TR, NOUD, and TDC more clearly:
503 503  
411 +[[image:1692424376354-959.png]]
504 504  
505 -(((
506 -Get the distance. Flat object range 20mm - 2000mm.
507 -)))
508 508  
509 -(((
510 -For example, if the data you get from the register is **0x06 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
414 +== 2.5 Humidity and Temperature alarm function ==
511 511  
512 -(% style="color:blue" %)**0605(H) = 1541 (D) = 1541 mm.**
513 -)))
514 514  
515 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
417 +On each sampling define by AT+TR ( default 900s or 15 minutes), when the value exceed the range, it will trigger an Alarm and immediately sends a uplink.
516 516  
517 -* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid.
518 518  
519 -=== 2.3.3  Interrupt Pin ===
420 +(% style="color:blue" %)**AT Commands:**
520 520  
422 +(% style="color:#037691" %)**AT+ SHHUM=min,max**
521 521  
522 -This data field shows if this packet is generated by interrupt or not.
424 +Example: AT+ SHHUM=50,80  ~/~/ Alarm when humidity lower than 50 or higher than 80.
523 523  
524 -**Example:**
525 525  
526 -0x00: Normal uplink packet.
427 +(% style="color:#037691" %)**AT+ SHTEMP=min,max**
527 527  
528 -0x01: Interrupt Uplink Packet.
429 +Example: AT+ SHTEMP=20,30  ~/~/ Alarm when temperature lower than 20 or higher than 30
529 529  
530 530  
531 -=== 2.3.4  DS18B20 Temperature sensor ===
432 +(% style="color:red" %)**Notice:**
532 532  
434 +* To disable Alarm, user can set min and max to same value , such as (% style="color:#037691" %)**AT+SHTEMP=0,0.**
533 533  
534 -This is optional, user can connect external DS18B20 sensor to the +3.3v, 1-wire and GND pin . and this field will report temperature.
436 +* If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.**
535 535  
536 -**Example**:
537 -
538 -If payload is: 0105H:  (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree
539 -
540 -If payload is: FF3FH :  (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees.
541 -
542 -
543 -=== 2.3.5  Sensor Flag ===
544 -
545 -
546 -(((
547 -0x01: Detect Ultrasonic Sensor
548 -)))
549 -
550 -(((
551 -0x00: No Ultrasonic Sensor
552 -
553 -
554 -)))
555 -
556 -== 2.4 Test Uplink and Change Update Interval ==
557 -
558 -
559 -By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8
560 -
561 -User can use below commands to change the (% style="color:blue" %)**uplink interval**.
562 -
563 -(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s
564 -
565 -User can also push the button for more than 1 seconds to activate an uplink.
566 -
567 -
568 -== 2.5 Multi-Samplings and One uplink ==
569 -
570 -
571 -To save battery life, DDS20-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
572 -
573 -* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
574 -
575 -* (% style="color:#037691" %)**AT+NOUD=8**     (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
576 -
577 -The diagram below explains the relationship between TR, NOUD, and TDC more clearly:
578 -
579 -[[image:1692424376354-959.png]]
580 -
581 -
582 582  == 2.6 Trggier an uplink by external interrupt ==
583 583  
584 584  
585 -DDS20-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.
441 +S31-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.
586 586  
587 587  (% style="color:blue" %)**AT command:**
588 588  
... ... @@ -596,12 +596,12 @@
596 596  
597 597  * (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
598 598  
599 -= 3. Configure DDS20-NB =
455 += 3. Configure S31x-NB =
600 600  
601 601  == 3.1 Configure Methods ==
602 602  
603 603  
604 -DDS20-NB supports below configure method:
460 +S31x-NB supports below configure method:
605 605  
606 606  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
607 607  
... ... @@ -690,7 +690,7 @@
690 690  = 4. Battery & Power Consumption =
691 691  
692 692  
693 -DDS20-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
549 +S31x-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
694 694  
695 695  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
696 696  
... ... @@ -722,22 +722,11 @@
722 722  [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
723 723  
724 724  
725 -= 7.  Trouble Shooting =
581 += 7. Order Info =
726 726  
727 -== 7.1  Why i always see 0x0000 or 0 for the distance value? ==
728 728  
584 +Part Number: (% style="color:blue" %)**S31-NB-XX  / S31B-NB-XX**
729 729  
730 -(((
731 -DDS20-NB has a strict [[**installation requirement**>>||anchor="H1.5A0InstallDDS20-NB"]]. Please make sure the installation method exactly follows up with the installation requirement. Otherwise, the reading might be always 0x00.
732 -
733 -If you have followed the instruction requirement exactly but still see the 0x00 reading issue, please. please double-check the decoder, you can check the raw payload to verify.
734 -)))
735 -
736 -= 8. Order Info =
737 -
738 -
739 -Part Number: (% style="color:blue" %)**DDS20-NB-XX**
740 -
741 741  (% style="color:red" %)**XX**(%%):
742 742  
743 743  * (% style="color:#037691" %)**GE**(%%): General version ( Exclude SIM card)
... ... @@ -747,12 +747,12 @@
747 747  (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands
748 748  
749 749  
750 -= 9. ​Packing Info =
595 += 8. ​Packing Info =
751 751  
752 752  
753 753  (% style="color:#037691" %)**Package Includes**:
754 754  
755 -* DDS20-NB NB-IoT Ultrasonic liquid level sensor x 1
600 +* S31-NB or S31-NB NB-IoT Sensor Node x 1
756 756  
757 757  * External antenna x 1
758 758  
... ... @@ -766,7 +766,7 @@
766 766  
767 767  * Weight / pcs : 180g
768 768  
769 -= 10. Support =
614 += 9. Support =
770 770  
771 771  
772 772  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.