Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -16,19 +16,19 @@ 16 16 == 1.1 What is DDS20-NB NB-IoT Ultrasonic liquid level Sensor == 17 17 18 18 19 -The Dragino DDS20-NB is a (% style="color:blue" %)**NB-IoT Ultrasonic liquid level sensor**(%%)for Internet of Things solution. It uses(% style="color:blue" %)**none-contact method **(%%)to measure the(% style="color:blue" %)**height of liquid**(%%)in a container without opening the container, and send IoT platform via NB-IoT network.19 +The Dragino DDS20-NB is a **NB-IoT Ultrasonic liquid level sensor** for Internet of Things solution. It uses **none-contact method **to measure the **height of liquid** in a container without opening the container, and send IoT platform via NB-IoT network. 20 20 21 21 The DDS20-NB sensor is installed directly below the container to detect the height of the liquid level. User doesn't need to open a hole on the container to be tested. The none-contact measurement makes the measurement safety, easier and possible for some strict situation. 22 22 23 -DDS20-NB uses (% style="color:blue" %)**ultrasonic sensing technology**(%%)for distance measurement. DDS20-NB is of high accuracy to measure various liquid such as:(% style="color:blue" %)**toxic substances**, **strong acids**, **strong alkalis**(%%)and(% style="color:blue" %)**various pure liquids**(%%)in high-temperature and high-pressure airtight containers.23 +DDS20-NB uses **ultrasonic sensing technology** for distance measurement. DDS20-NB is of high accuracy to measure various liquid such as: **toxic substances**, **strong acids**, **strong alkalis** and **various pure liquids** in high-temperature and high-pressure airtight containers. 24 24 25 - DDS20-NB supports different uplink methods including(% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%)for different application requirement, and support uplinks to various IoT Servers.25 +PS-NB-NA supports different uplink methods including **MQTT, MQTTs, UDP & TCP** for different application requirement, and support uplinks to various IoT Servers. 26 26 27 - DDS20-NB(% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%)which make user easy to use.27 +PS-NB-NA **supports BLE configure **and** OTA update** which make user easy to use. 28 28 29 - DDS20-NB is powered by(% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long-term use up to severa years.29 +PS-NB-NA is powered by **8500mAh Li-SOCI2 battery**, it is designed for long-term use up to severa years. 30 30 31 - DDS20-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration.31 +PS-NB-NA has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration. 32 32 33 33 34 34 [[image:image-20230911140426-2.png||height="320" width="951"]] ... ... @@ -295,25 +295,8 @@ 295 295 (% style="display:none" %) 296 296 297 297 298 -= =1.12Mechanical==298 += 2. Use S31-NB to communicate with IoT Server = 299 299 300 - 301 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143884058-338.png?rev=1.1||alt="1675143884058-338.png"]] 302 - 303 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143899218-599.png?rev=1.1||alt="1675143899218-599.png"]] 304 - 305 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143909447-639.png?rev=1.1||alt="1675143909447-639.png"]] 306 - 307 - 308 -(% style="color:blue" %)**Probe Mechanical:** 309 - 310 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-1.png?rev=1.1||alt="image-20220615090910-1.png"]] 311 - 312 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615090910-2.png?rev=1.1||alt="image-20220615090910-2.png"]] 313 - 314 - 315 -= 2. Use DDS20-NB to communicate with IoT Server = 316 - 317 317 == 2.1 Send data to IoT server via NB-IoT network == 318 318 319 319 ... ... @@ -413,7 +413,7 @@ 413 413 414 414 These bytes include the hardware and software version. 415 415 416 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x00 for DDS20-NB399 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x00 for S31B-NB & S31-NB 417 417 418 418 (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 100 419 419 ... ... @@ -440,6 +440,20 @@ 440 440 **99** Not known or not detectable 441 441 442 442 426 +(% style="color:blue" %)**Temperature: ** 427 + 428 +If payload is: 0105H: (0105 & 8000 == 0), temp = 0105H /10 = 26.1 degree 429 + 430 +If payload is: FF3FH : (FF3F & 8000 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 431 + 432 +(FF3F & 8000: Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 433 + 434 + 435 +(% style="color:blue" %)**Humidity: ** 436 + 437 +Read:0295(H)=661(D) Value: 661 / 10=66.1, So 66.1% 438 + 439 + 443 443 (% style="color:blue" %)**TimeStamp: ** 444 444 445 445 Unit TimeStamp Example: 64d49439(H) = 1691653177(D) ... ... @@ -466,123 +466,61 @@ 466 466 467 467 (% style="color:#4472c4" %)**field1=27.9&field2=49.9&field3=3.23&field4=28** 468 468 469 -== 2.3 Uplink Payload == 470 470 467 +== 2.3 Test Uplink and Change Update Interval == 471 471 472 -((( 473 -DDS20-NB will uplink payload via LoRaWAN with below payload format: 474 -))) 475 475 476 -((( 477 -Uplink payload includes in total 8 bytes. 478 -))) 470 +By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8 479 479 480 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 481 -|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1 482 -|(% style="width:95px" %)Value|(% style="width:61px" %)[[BAT>>||anchor="H2.3.2A0BatteryInfo"]]|((( 483 -[[Distance>>||anchor="H2.3.3A0Distance"]] 484 -(unit: mm) 485 -)))|[[Digital Interrupt (Optional)>>||anchor="H2.3.4A0InterruptPin"]]|((( 486 -[[Temperature (Optional)>>||anchor="H2.3.5A0DS18B20Temperaturesensor"]] 487 -)))|[[Sensor Flag>>||anchor="H2.3.6A0SensorFlag"]] 472 +User can use below commands to change the (% style="color:blue" %)**uplink interval**. 488 488 489 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/%E5%BE%AE%E4%BF%A1%E6%88%AA%E5%9B%BE_20230702135733.png?width=964&height=215&rev=1.1||alt="微信截图_20230702135733.png"]]474 +(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s 490 490 476 +User can also push the button for more than 1 seconds to activate an uplink. 491 491 492 -=== 2.3.1 Battery Info === 493 493 479 +== 2.4 Multi-Samplings and One uplink == 494 494 495 -Check the battery voltage for DDS20-NB. 496 496 497 - Ex1:0x0B45=2885mV482 +To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 498 498 499 - Ex2:0x0B49 =2889mV484 +* (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 500 500 486 +* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 501 501 502 - ===2.3.2Distance===488 +The diagram below explains the relationship between TR, NOUD, and TDC more clearly: 503 503 490 +[[image:1692424376354-959.png]] 504 504 505 -((( 506 -Get the distance. Flat object range 20mm - 2000mm. 507 -))) 508 508 509 -((( 510 -For example, if the data you get from the register is **0x06 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 493 +== 2.5 Humidity and Temperature alarm function == 511 511 512 -(% style="color:blue" %)**0605(H) = 1541 (D) = 1541 mm.** 513 -))) 514 514 515 - *If the sensorvalueis0x0000,itmeanssystemdoesn'tdetectultrasonicsensor.496 +On each sampling define by AT+TR ( default 900s or 15 minutes), when the value exceed the range, it will trigger an Alarm and immediately sends a uplink. 516 516 517 -* If the sensor value lower than 0x0014 (20mm), the sensor value will be invalid. 518 518 519 - ===2.3.3 InterruptPin===499 +(% style="color:blue" %)**AT Commands:** 520 520 501 +(% style="color:#037691" %)**AT+ SHHUM=min,max** 521 521 522 -T hisdatafieldshowsifthispacketis generatedbyinterrupt ornot.503 +Example: AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50 or higher than 80. 523 523 524 -**Example:** 525 525 526 - 0x00:Normaluplink packet.506 +(% style="color:#037691" %)**AT+ SHTEMP=min,max** 527 527 528 - 0x01:InterruptUplinkPacket.508 +Example: AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20 or higher than 30 529 529 530 530 531 - ===2.3.4 DS18B20 Temperaturesensor ===511 +(% style="color:red" %)**Notice:** 532 532 513 +* To disable Alarm, user can set min and max to same value , such as (% style="color:#037691" %)**AT+SHTEMP=0,0.** 533 533 534 - Thisis optional, user canconnectexternalDS18B20 sensor tothe+3.3v, 1-wire andGND pin . andthis fieldwillreporttemperature.515 +* If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.** 535 535 536 -**Example**: 537 - 538 -If payload is: 0105H: (0105 & FC00 == 0), temp = 0105H /10 = 26.1 degree 539 - 540 -If payload is: FF3FH : (FF3F & FC00 == 1) , temp = (FF3FH - 65536)/10 = -19.3 degrees. 541 - 542 - 543 -=== 2.3.5 Sensor Flag === 544 - 545 - 546 -((( 547 -0x01: Detect Ultrasonic Sensor 548 -))) 549 - 550 -((( 551 -0x00: No Ultrasonic Sensor 552 - 553 - 554 -))) 555 - 556 -== 2.4 Test Uplink and Change Update Interval == 557 - 558 - 559 -By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8 560 - 561 -User can use below commands to change the (% style="color:blue" %)**uplink interval**. 562 - 563 -(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s 564 - 565 -User can also push the button for more than 1 seconds to activate an uplink. 566 - 567 - 568 -== 2.5 Multi-Samplings and One uplink == 569 - 570 - 571 -To save battery life, DDS20-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 572 - 573 -* (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 574 - 575 -* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 576 - 577 -The diagram below explains the relationship between TR, NOUD, and TDC more clearly: 578 - 579 -[[image:1692424376354-959.png]] 580 - 581 - 582 582 == 2.6 Trggier an uplink by external interrupt == 583 583 584 584 585 - DDS20-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.520 +S31-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets. 586 586 587 587 (% style="color:blue" %)**AT command:** 588 588 ... ... @@ -596,12 +596,12 @@ 596 596 597 597 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 598 598 599 -= 3. Configure DDS20-NB =534 += 3. Configure S31x-NB = 600 600 601 601 == 3.1 Configure Methods == 602 602 603 603 604 - DDS20-NB supports below configure method:539 +S31x-NB supports below configure method: 605 605 606 606 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 607 607 ... ... @@ -690,7 +690,7 @@ 690 690 = 4. Battery & Power Consumption = 691 691 692 692 693 - DDS20-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.628 +S31x-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 694 694 695 695 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 696 696 ... ... @@ -722,22 +722,11 @@ 722 722 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 723 723 724 724 725 -= 7. TroubleShooting=660 += 7. Order Info = 726 726 727 -== 7.1 Why i always see 0x0000 or 0 for the distance value? == 728 728 663 +Part Number: (% style="color:blue" %)**S31-NB-XX / S31B-NB-XX** 729 729 730 -((( 731 -DDS20-NB has a strict [[**installation requirement**>>||anchor="H1.5A0InstallDDS20-NB"]]. Please make sure the installation method exactly follows up with the installation requirement. Otherwise, the reading might be always 0x00. 732 - 733 -If you have followed the instruction requirement exactly but still see the 0x00 reading issue, please. please double-check the decoder, you can check the raw payload to verify. 734 -))) 735 - 736 -= 8. Order Info = 737 - 738 - 739 -Part Number: (% style="color:blue" %)**DDS20-NB-XX** 740 - 741 741 (% style="color:red" %)**XX**(%%): 742 742 743 743 * (% style="color:#037691" %)**GE**(%%): General version ( Exclude SIM card) ... ... @@ -747,12 +747,12 @@ 747 747 (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 748 748 749 749 750 -= 9. Packing Info =674 += 8. Packing Info = 751 751 752 752 753 753 (% style="color:#037691" %)**Package Includes**: 754 754 755 -* DDS20-NB NB-IoTUltrasonic liquid level sensor x 1679 +* S31-NB or S31-NB NB-IoT Sensor Node x 1 756 756 757 757 * External antenna x 1 758 758 ... ... @@ -766,7 +766,7 @@ 766 766 767 767 * Weight / pcs : 180g 768 768 769 -= 10. Support =693 += 9. Support = 770 770 771 771 772 772 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.