Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -298,8 +298,6 @@ 298 298 299 299 * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time. 300 300 301 - 302 - 303 303 === 2.2.2 HEX format Payload(Type~=0) === 304 304 305 305 ... ... @@ -350,6 +350,7 @@ 350 350 (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 351 351 352 352 351 + 353 353 (% style="color:blue" %)**Humidity: ** 354 354 355 355 Read:0295(H)=661(D) Value: 661 / 10=66.1, So 66.1% ... ... @@ -367,6 +367,7 @@ 367 367 368 368 Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard. 369 369 369 + 370 370 (% style="color:#4472c4" %)**{"IMEI":866207053462762,"temperature":29.2,"humidity":54.2,"battery":3.27,"signal":24}** 371 371 372 372 ... ... @@ -377,6 +377,7 @@ 377 377 378 378 Temperature, Humidity, Battery & Signal. This payload type only valid for ThingsSpeak Platform 379 379 380 + 380 380 As below: 381 381 382 382 (% style="color:#4472c4" %)**field1=27.9&field2=49.9&field3=3.23&field4=28** ... ... @@ -387,6 +387,7 @@ 387 387 388 388 By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8 389 389 391 + 390 390 User can use below commands to change the (% style="color:blue" %)**uplink interval**. 391 391 392 392 (% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s ... ... @@ -399,9 +399,9 @@ 399 399 400 400 To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 401 401 402 -* (% style="color:#037691" %)**AT+TR=900** (%%) 404 +* (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 403 403 404 -* (% style="color:#037691" %)**AT+NOUD=8** 406 +* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 405 405 406 406 The diagram below explains the relationship between TR, NOUD, and TDC more clearly: 407 407 ... ... @@ -418,12 +418,12 @@ 418 418 419 419 (% style="color:#037691" %)**AT+ SHHUM=min,max** 420 420 421 -Example: AT+ SHHUM=50,80 423 +Example: AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50 or higher than 80. 422 422 423 423 424 424 (% style="color:#037691" %)**AT+ SHTEMP=min,max** 425 425 426 -Example: AT+ SHTEMP=20,30 428 +Example: AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20 or higher than 30 427 427 428 428 429 429 (% style="color:red" %)**Notice:** ... ... @@ -441,15 +441,15 @@ 441 441 442 442 (% style="color:blue" %)**AT command:** 443 443 444 -* (% style="color:#037691" %)**AT+INTMOD **(%%) 446 +* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode 445 445 446 -* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/ 448 +* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/Disable Interrupt 447 447 448 -* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) 450 +* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/Trigger by rising and falling edge 449 449 450 -* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) 452 +* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/Trigger by falling edge 451 451 452 -* (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ 454 +* (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/Trigger by rising edge 453 453 454 454 455 455 = 3. Configure S31x-NB = ... ... @@ -463,86 +463,200 @@ 463 463 464 464 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 465 465 466 - ==3.2ATCommands Set==468 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 467 467 468 468 469 - AT+<CMD>?: Helpon<CMD>471 +== 3.2 General Commands == 470 470 471 -AT+<CMD> : Run <CMD> 472 472 473 - AT+<CMD>=<value>: Setthevalue474 +These commands are to configure: 474 474 475 -AT+<CMD>=? : Get the value 476 +* General system settings like: uplink interval. 477 +* LoRaWAN protocol & radio related command. 476 476 479 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 477 477 478 - **General**481 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 479 479 480 -AT : Attention 481 481 482 - AT?: ShortHelp484 +== 3.3 Commands special design for S31x-LB == 483 483 484 -ATZ : MCU Reset 485 485 486 - AT+TDC: ApplicationDataTransmissionInterval487 +These commands only valid for S31x-LB, as below: 487 487 488 -AT+CFG : Print all configurations 489 489 490 - AT+CFGMOD:Workingmodeselection490 +=== 3.3.1 Set Transmit Interval Time === 491 491 492 -AT+DEUI : Get or set the Device ID 493 493 494 - AT+INTMOD : Setthetriggerinterruptmode493 +Feature: Change LoRaWAN End Node Transmit Interval. 495 495 496 - AT+5VT: Setxtendthetimeof 5V power495 +(% style="color:blue" %)**AT Command: AT+TDC** 497 497 498 -AT+PRO : Choose agreement 497 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 498 +|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response** 499 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 500 +30000 501 +OK 502 +the interval is 30000ms = 30s 503 +))) 504 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 505 +OK 506 +Set transmit interval to 60000ms = 60 seconds 507 +))) 499 499 500 - AT+RXDL: Extend thesendingandreceiving time509 +(% style="color:blue" %)**Downlink Command: 0x01** 501 501 502 - AT+DNSCFG:GetorSetDNSServer511 +Format: Command Code (0x01) followed by 3 bytes time value. 503 503 504 - AT+GETSENSORVALUE: Returns thecurrentsensormeasurement513 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 505 505 506 -AT+NOUD : Get or Set the number of data to be uploaded 515 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 516 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 507 507 508 - AT+CDP:Reador Clearcacheddata518 +=== 3.3.2 Get Device Status === 509 509 510 -AT+SHTEMP: Get or Set alarm of temp 511 511 512 - AT+SHHUM:GetorSet alarmof moisture521 +Send a LoRaWAN downlink to ask device send Alarm settings. 513 513 514 - AT+SERVADDR: ServerAddress523 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 515 515 525 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 516 516 517 -**UDP Management** 518 518 519 - AT+CFM:Upload confirmationmode(only validfor UDP)528 +=== 3.3.3 Set Temperature Alarm Threshold === 520 520 521 521 522 -** MQTTManagement**531 +* (% style="color:blue" %)**AT Command:** 523 523 524 - AT+CLIENT: Getet MQTT client533 +(% style="color:#037691" %)**AT+SHTEMP=min,max** 525 525 526 -AT+UNAME : Get or Set MQTT Username 535 +* When min=0, and max≠0, Alarm higher than max 536 +* When min≠0, and max=0, Alarm lower than min 537 +* When min≠0 and max≠0, Alarm higher than max or lower than min 527 527 528 - AT+PWD : Get or Set MQTT password539 +Example: 529 529 530 -AT+ PUBTOPIC: GetorSetMQTT publish topic541 + AT+SHTEMP=0,30 ~/~/ Alarm when temperature higher than 30. 531 531 532 - AT+SUBTOPIC: GetSetMQTT subscriptiontopic543 +* (% style="color:blue" %)**Downlink Payload:** 533 533 545 +(% style="color:#037691" %)**0x(0C 01 00 1E)** (%%) ~/~/ Set AT+SHTEMP=0,30 534 534 535 -** Information**547 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)** 536 536 537 -AT+FDR : Factory Data Reset 538 538 539 - AT+PWORD:SerialAccess Password550 +=== 3.3.4 Set Humidity Alarm Threshold === 540 540 541 -AT+LDATA : Get the last upload data 542 542 543 - AT+CDP: ReadorClearcacheddata553 +* (% style="color:blue" %)**AT Command:** 544 544 555 +(% style="color:#037691" %)**AT+SHHUM=min,max** 545 545 557 +* When min=0, and max≠0, Alarm higher than max 558 +* When min≠0, and max=0, Alarm lower than min 559 +* When min≠0 and max≠0, Alarm higher than max or lower than min 560 + 561 +Example: 562 + 563 + AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 564 + 565 +* (% style="color:blue" %)**Downlink Payload:** 566 + 567 +(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/ Set AT+SHTHUM=70,0 568 + 569 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 570 + 571 + 572 +=== 3.3.5 Set Alarm Interval === 573 + 574 + 575 +The shortest time of two Alarm packet. (unit: min) 576 + 577 +* (% style="color:blue" %)**AT Command:** 578 + 579 +(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 580 + 581 +* (% style="color:blue" %)**Downlink Payload:** 582 + 583 +(% style="color:#037691" %)**0x(0D 00 1E)**(%%) **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 584 + 585 + 586 +=== 3.3.6 Get Alarm settings === 587 + 588 + 589 +Send a LoRaWAN downlink to ask device send Alarm settings. 590 + 591 +* (% style="color:#037691" %)**Downlink Payload: **(%%)0x0E 01 592 + 593 +**Example:** 594 + 595 +[[image:image-20230524110211-4.png]] 596 + 597 +**Explain:** 598 + 599 +* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 600 + 601 +=== 3.3.7 Set Interrupt Mode === 602 + 603 + 604 +Feature, Set Interrupt mode for PA8 of pin. 605 + 606 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 607 + 608 +(% style="color:blue" %)**AT Command: AT+INTMOD** 609 + 610 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 611 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 612 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 613 +0 614 +OK 615 +the mode is 0 =Disable Interrupt 616 +))) 617 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 618 +Set Transmit Interval 619 +0. (Disable Interrupt), 620 +~1. (Trigger by rising and falling edge) 621 +2. (Trigger by falling edge) 622 +3. (Trigger by rising edge) 623 +)))|(% style="width:157px" %)OK 624 + 625 +(% style="color:blue" %)**Downlink Command: 0x06** 626 + 627 +Format: Command Code (0x06) followed by 3 bytes. 628 + 629 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 630 + 631 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 632 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 633 + 634 +=== 3.3.8 Set Power Output Duration === 635 + 636 + 637 +Control the output duration 5V . Before each sampling, device will 638 + 639 +~1. first enable the power output to external sensor, 640 + 641 +2. keep it on as per duration, read sensor value and construct uplink payload 642 + 643 +3. final, close the power output. 644 + 645 +(% style="color:blue" %)**AT Command: AT+5VT** 646 + 647 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 648 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 649 +|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default) 650 +OK 651 +|(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK 652 + 653 +(% style="color:blue" %)**Downlink Command: 0x07** 654 + 655 +Format: Command Code (0x07) followed by 2 bytes. 656 + 657 +The first and second bytes are the time to turn on. 658 + 659 +* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 660 +* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 661 + 546 546 = 4. Battery & Power Consumption = 547 547 548 548