... ... @@ -298,8 +298,6 @@
298 298  
299 299  * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time.
300 300  
301 -
302 -
303 303  === 2.2.2 HEX format Payload(Type~=0) ===
304 304  
305 305  
... ... @@ -350,6 +350,7 @@
350 350  (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative)
351 351  
352 352  
351 +
353 353  (% style="color:blue" %)**Humidity:   **
354 354  
355 355  Read:0295(H)=661(D)    Value:  661 / 10=66.1, So 66.1%
... ... @@ -399,9 +399,9 @@
399 399  
400 400  To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
401 401  
402 -* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
401 +* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/  The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
403 403  
404 -* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
403 +* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/   The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
405 405  
406 406  The diagram below explains the relationship between TR, NOUD, and TDC more clearly:
407 407  
... ... @@ -418,12 +418,12 @@
418 418  
419 419  (% style="color:#037691" %)**AT+ SHHUM=min,max**
420 420  
421 -Example: AT+ SHHUM=50,80  ~/~/ Alarm when humidity lower than 50 or higher than 80.
420 +Example: AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50 or higher than 80.
422 422  
423 423  
424 424  (% style="color:#037691" %)**AT+ SHTEMP=min,max**
425 425  
426 -Example: AT+ SHTEMP=20,30  ~/~/ Alarm when temperature lower than 20 or higher than 30
425 +Example: AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20 or higher than 30
427 427  
428 428  
429 429  (% style="color:red" %)**Notice:**
... ... @@ -441,15 +441,15 @@
441 441  
442 442  (% style="color:blue" %)**AT command:**
443 443  
444 -* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
443 +* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
445 445  
446 -* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/ Disable Interrupt
445 +* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/Disable Interrupt
447 447  
448 -* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/ Trigger by rising and falling edge
447 +* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/Trigger by rising and falling edge
449 449  
450 -* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/ Trigger by falling edge
449 +* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/Trigger by falling edge
451 451  
452 -* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
451 +* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/Trigger by rising edge
453 453  
454 454  
455 455  = 3. Configure S31x-NB =