Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -S 31-NB/S31B-NB_BN-IoTOutdoorTemperature& HumiditySensor User Manual1 +DDS20-NB -- NB-IoT Ultrasonic Liquid Level Sensor User Manual - Content
-
... ... @@ -1,8 +1,7 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20230 819102136-3.png]]2 +[[image:image-20230911134259-1.png||height="570" width="570"]] 3 3 4 4 5 - 6 6 **Table of Contents:** 7 7 8 8 {{toc/}} ... ... @@ -14,61 +14,52 @@ 14 14 15 15 = 1. Introduction = 16 16 17 -== 1.1 What is S 31x-NB NB-IoTTemperature& HumiditySensor ==16 +== 1.1 What is DDS20-NB NB-IoT Ultrasonic liquid level Sensor == 18 18 19 19 20 -The Dragino S 31-NBand S31B-NB are (%style="color:blue"%)**NB-IoTTemperatureandHumiditySensor**(%%)for Internet of Things solution. Itisused to measure thesurrounding(%style="color:blue" %)**environmenttemperatureand relativeair humidityprecisely**(%%), andthenuploadtoIoTservervia NB-IoT network*.19 +The Dragino DDS20-NB is a **NB-IoT Ultrasonic liquid level sensor** for Internet of Things solution. It uses **none-contact method **to measure the **height of liquid** in a container without opening the container, and send IoT platform via NB-IoT network. 21 21 22 -The temperature& humiditysensorusedinS31-NB isSHT31, which is fullycalibrated,linearized,andtemperatureompensateddigitaloutputfromSensirion,itprovidesastrongreliabilityandlong-termstability.TheSHT31 isfixedina (% style="color:blue"%)**waterproofanti-condensationcasing**(%%)forlongtermuse.21 +The DDS20-NB sensor is installed directly below the container to detect the height of the liquid level. User doesn't need to open a hole on the container to be tested. The none-contact measurement makes the measurement safety, easier and possible for some strict situation. 23 23 24 -S 31-NB supportsdifferentuplinkmethods include(%style="color:blue" %)**TCP,MQTT, UDP**(%%) fordifferentapplicationrequirement.andSupport Uplinksto variousIoT Servers.23 +DDS20-NB uses **ultrasonic sensing technology** for distance measurement. DDS20-NB is of high accuracy to measure various liquid such as: **toxic substances**, **strong acids**, **strong alkalis** and **various pure liquids** in high-temperature and high-pressure airtight containers. 25 25 26 -S 31-NBiswered by (% style="color:blue"%)**8500mAh Li-SOCI2 battery**(%%), It isdesigned forlongterm useuptoseveralyears. (Real-world battery life dependsonthese environment,updateperiodanduplinkmethod.Pleasecheck related PowerAnalyzeport).25 +PS-NB-NA supports different uplink methods including **MQTT, MQTTs, UDP & TCP** for different application requirement, and support uplinks to various IoT Servers. 27 27 28 -* makesureyouhaveNB-IoTcoveragelocally.27 +PS-NB-NA **supports BLE configure **and** OTA update** which make user easy to use. 29 29 29 +PS-NB-NA is powered by **8500mAh Li-SOCI2 battery**, it is designed for long-term use up to severa years. 30 30 31 - [[image:1692411831805-116.png]]31 +PS-NB-NA has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration. 32 32 33 33 34 +[[image:image-20230911140426-2.png||height="320" width="951"]] 35 + 36 + 34 34 == 1.2 Features == 35 35 36 36 37 37 * NB-IoT Bands: B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 @H-FDD 38 38 * Ultra-low power consumption 39 -* External 3 meters SHT31 probe (For S31-NB) 40 -* Measure range -40°C ~~ 85°C 41 -* Temperature & Humidity alarm 42 +* Liquid Level Measurement by Ultrasonic technology 43 +* Measure through container, No need to contact Liquid 44 +* Valid level range 20mm - 2000mm 45 +* Accuracy: ±(5mm+S*0.5%) (S: Measure Value) 42 42 * Multiply Sampling and one uplink 43 43 * Support Bluetooth v5.1 remote configure and update firmware 44 44 * Uplink on periodically 45 45 * Downlink to change configure 50 +* IP66 Waterproof Enclosure 46 46 * 8500mAh Battery for long term use 47 47 * Nano SIM card slot for NB-IoT SIM 48 48 49 - 50 50 == 1.3 Specification == 51 51 52 52 53 53 (% style="color:blue" %)**Common DC Characteristics:** 54 54 55 -* Supply Voltage: 2. 1v ~~ 3.6v59 +* Supply Voltage: 2.5v ~~ 3.6v 56 56 * Operating Temperature: -40 ~~ 85°C 57 57 58 -(% style="color:blue" %)**Temperature Sensor:** 59 - 60 -* Range: -40 to + 80°C 61 -* Accuracy: ±0.2 @ 0-90 °C 62 -* Resolution: 0.1°C 63 -* Long Term Shift: <0.03 °C/yr 64 - 65 -(% style="color:blue" %)**Humidity Sensor: ** 66 - 67 -* Range: 0 ~~ 99.9% RH 68 -* Accuracy: ± 2%RH ( 0 ~~ 100%RH) 69 -* Resolution: 0.01% RH 70 -* Long Term Shift: <0.25 %RH/yr 71 - 72 72 (% style="color:blue" %)**NB-IoT Spec:** 73 73 74 74 (% style="color:#037691" %)**NB-IoT Module: BC660K-GL** ... ... @@ -106,29 +106,144 @@ 106 106 * STOP Mode: 10uA @ 3.3v 107 107 * Max transmit power: 350mA@3.3v 108 108 99 +== 1.4 Suitable Container & Liquid == 109 109 110 110 111 -== 1.4 Applications == 102 +* Solid Wall container such as: steel, iron, glass, ceramics, non-foaming plastics etc. 103 +* Container shape is regular, and surface is smooth. 104 +* Container Thickness: 105 +** Pure metal material. 2~~8mm, best is 3~~5mm 106 +** Pure non metal material: <10 mm 107 +* Pure liquid without irregular deposition. 112 112 109 +(% style="display:none" %) 113 113 114 -* Smart Buildings & Home Automation 115 -* Logistics and Supply Chain Management 116 -* Smart Metering 117 -* Smart Agriculture 118 -* Smart Cities 119 -* Smart Factory 111 +== 1.5 Install DDS20-NB == 120 120 121 121 114 +(% style="color:blue" %)**Step 1**(%%): ** Choose the installation point.** 122 122 123 - ==1.5Sleep modeandworkingmode==116 +DDS20-NB (% style="color:red" %)**MUST**(%%) be installed on the container bottom middle position. 124 124 118 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS20%20-%20LoRaWAN%20Liquid%20Level%20Sensor%20User%20Manual/WebHome/image-20220615091045-3.png?rev=1.1||alt="image-20220615091045-3.png"]] 125 125 120 + 121 +((( 122 +(% style="color:blue" %)**Step 2**(%%): **Polish the installation point.** 123 +))) 124 + 125 +((( 126 +For Metal Surface with paint, it is important to polish the surface, first use crude sand paper to polish the paint level , then use exquisite sand paper to polish the metal level to make it shine & smooth. 127 +))) 128 + 129 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/image-20230613143052-5.png?rev=1.1||alt="image-20230613143052-5.png"]] 130 + 131 + 132 +No polish needed if the container is shine metal surface without paint or non-metal container. 133 + 134 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-LB_LoRaWAN_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/image-20230613143125-6.png?rev=1.1||alt="image-20230613143125-6.png"]] 135 + 136 + 137 +((( 138 +(% style="color:blue" %)**Step3: **(%%)**Test the installation point.** 139 +))) 140 + 141 +((( 142 +Power on DDS20-NB, check if the blue LED is on, If the blue LED is on, means the sensor works. Then put ultrasonic coupling paste on the sensor and put it tightly on the installation point. 143 +))) 144 + 145 +((( 146 +It is necessary to put the coupling paste between the sensor and the container, otherwise DDS20-NB won't detect the liquid level. 147 +))) 148 + 149 +((( 150 +After paste the DDS20-NB well, power on DDS20-NB. In the first 30 seconds of booting, device will check the sensors status and BLUE LED will show the status as below. After 30 seconds, BLUE LED will be off to save battery life. 151 +))) 152 + 153 + 154 +((( 155 +(% style="color:blue" %)**LED Status:** 156 +))) 157 + 158 +* ((( 159 +**Onboard LED**: When power on device, the onboard LED will fast blink 4 times which means detect the sensor well. 160 +))) 161 + 162 +* ((( 163 +(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** always ON**(%%): Sensor is power on but doesn't detect liquid. There is problem in installation point. 164 +))) 165 +* ((( 166 +(% style="color:blue" %)**BLUE LED**(% style="color:red" %)** slowly blinking**(%%): Sensor detects Liquid Level, The installation point is good. 167 +))) 168 + 169 +((( 170 +DDS20-NB will enter into low power mode at 30 seconds after system reset or power on, Blue LED will be off after that. 171 +))) 172 + 173 + 174 +((( 175 +(% style="color:red" %)**Note :**(%%)** (% style="color:blue" %)Ultrasonic coupling paste(%%)**(% style="color:blue" %) (%%) is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally. 176 +))) 177 + 178 + 179 +((( 180 +(% style="color:blue" %)**Step4: **(%%)**Install use Epoxy ab glue.** 181 +))) 182 + 183 +((( 184 +Prepare Eproxy AB glue. 185 +))) 186 + 187 +((( 188 +Put Eproxy AB glue in the sensor and press it hard on the container installation point. 189 +))) 190 + 191 +((( 192 +Reset DDS20-NB and see if the BLUE LED is slowly blinking. 193 +))) 194 + 195 +[[image:image-20230809172509-1.png]] 196 + 197 +((( 198 +(% style="color:red" %)**Note :**(% style="color:red; display:none" %)** ** 199 + 200 +(% style="color:red" %)**1:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** needs 3~~ 5 minutes to stable attached. we can use other glue material to keep it in the position. 201 +))) 202 + 203 +((( 204 +(% style="color:red" %)**2:**(%%)** (% style="color:blue" %)Eproxy AB glue(%%)** is subjected in most shipping way. So the default package doesn't include it and user needs to purchase locally. 205 +))) 206 + 207 + 208 +== 1.6 Applications == 209 + 210 + 211 +* Smart liquid control solution 212 + 213 +* Smart liquefied gas solution 214 + 215 +== 1.7 Precautions == 216 + 217 + 218 +* At room temperature, containers of different materials, such as steel, glass, iron, ceramics, non-foamed plastics and other dense materials, have different detection blind areas and detection limit heights. 219 + 220 +* For containers of the same material at room temperature, the detection blind zone and detection limit height are also different for the thickness of the container. 221 + 222 +* When the detected liquid level exceeds the effective detection value of the sensor, and the liquid level of the liquid to be measured shakes or tilts, the detected liquid height is unstable. 223 + 224 +(% style="display:none" %) 225 + 226 + 227 + 228 +== 1.8 Sleep mode and working mode == 229 + 230 + 126 126 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life. 127 127 128 128 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 129 129 130 130 131 -== 1. 6Button & LEDs ==236 +== 1.9 Button & LEDs == 132 132 133 133 134 134 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -147,14 +147,12 @@ 147 147 ))) 148 148 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 149 149 255 +== 1.10 BLE connection == 150 150 151 151 152 - ==1.7BLEconnection==258 +DDS20-NB support BLE remote configure and firmware update. 153 153 154 154 155 -S31x-NB support BLE remote configure and firmware update. 156 - 157 - 158 158 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: 159 159 160 160 * Press button to send an uplink ... ... @@ -164,21 +164,19 @@ 164 164 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 165 165 166 166 167 -== 1. 8Pin Definitions & Switch ==270 +== 1.11 Pin Definitions & Switch == 168 168 169 169 170 -S31x-NB use the mother board from S31-NB which as below. 171 - 172 172 [[image:image-20230819104805-5.png]] 173 173 174 174 175 -=== 1. 8.1 Jumper JP2 ===276 +=== 1.11.1 Jumper JP2 === 176 176 177 177 178 178 Power on Device when put this jumper. 179 179 180 180 181 -=== 1. 8.2 BOOT MODE / SW1 ===282 +=== 1.11.2 BOOT MODE / SW1 === 182 182 183 183 184 184 **1)** (% style="color:blue" %)**ISP**(%%): upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run. ... ... @@ -186,55 +186,25 @@ 186 186 **2)** (% style="color:blue" %)**Flash**(%%): work mode, device starts to work and send out console output for further debug 187 187 188 188 189 -=== 1. 8.3 Reset Button ===290 +=== 1.11.3 Reset Button === 190 190 191 191 192 192 Press to reboot the device. 193 193 194 - 195 -== 1.9 Hardware Variant == 196 - 197 - 198 -(% border="1" cellspacing="5" style="width:410px" %) 199 -|=(% style="width: 102px;background-color:#4F81BD;color:white" %)Model|=(% style="width: 126px; background-color:#4F81BD;color:white" %)Photo|=(% style="width: 179px;background-color:#4F81BD;color:white" %)Probe Info 200 -|(% style="width:102px" %)((( 201 -S31-NB 202 -)))|(% style="width:126px" %)((( 203 -(% style="text-align:center" %) 204 -[[image:image-20230819110632-6.png||height="130" width="104"]] 205 -)))|(% style="width:179px" %)((( 206 -1 x SHT31 Probe 207 - 208 -Cable Length : 3 meters 209 - 210 - 211 -))) 212 -|(% style="width:102px" %)((( 213 -S31B-NB 214 -)))|(% style="width:126px" %)((( 215 -(% style="text-align:center" %) 216 -[[image:image-20230819110702-7.png||height="164" width="90"]] 217 -)))|(% style="width:179px" %)((( 218 -1 x SHT31 Probe 219 - 220 -Installed in device. 221 -))) 222 - 223 223 (% style="display:none" %) 224 224 225 225 226 - 227 227 = 2. Use S31-NB to communicate with IoT Server = 228 228 229 229 == 2.1 Send data to IoT server via NB-IoT network == 230 230 231 231 232 -The S 31-NB is equipped with a NB-IoT module, the pre-loaded firmware in S31-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by S31-NB.303 +The DDS20-NB is equipped with a NB-IoT module, the pre-loaded firmware in DDS20-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by DDS20-NB. 233 233 234 234 235 235 Below shows the network structure: 236 236 237 -[[image:1692 415924540-357.png]]308 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DDS20-NB_NB-IoT_Ultrasonic_Liquid_Level_Sensor_User_Manual/WebHome/image-20230911140426-2.png?width=951&height=320&rev=1.1||alt="image-20230911140426-2.png"]] 238 238 239 239 240 240 There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of S31-NB. ... ... @@ -311,8 +311,6 @@ 311 311 312 312 * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time. 313 313 314 - 315 - 316 316 === 2.2.2 HEX format Payload(Type~=0) === 317 317 318 318 ... ... @@ -445,8 +445,6 @@ 445 445 446 446 * If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.** 447 447 448 - 449 - 450 450 == 2.6 Trggier an uplink by external interrupt == 451 451 452 452 ... ... @@ -464,8 +464,6 @@ 464 464 465 465 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 466 466 467 - 468 - 469 469 = 3. Configure S31x-NB = 470 470 471 471 == 3.1 Configure Methods == ... ... @@ -477,8 +477,6 @@ 477 477 478 478 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 479 479 480 - 481 - 482 482 == 3.2 AT Commands Set == 483 483 484 484 ... ... @@ -584,8 +584,6 @@ 584 584 585 585 * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 586 586 587 - 588 - 589 589 = 6. FAQ = 590 590 591 591 == 6.1 How can I access t BC660K-GL AT Commands? == ... ... @@ -629,8 +629,6 @@ 629 629 630 630 * Weight / pcs : 180g 631 631 632 - 633 - 634 634 = 9. Support = 635 635 636 636
- image-20230911134259-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +236.5 KB - Content
- image-20230911140426-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.6 KB - Content