298 298  
299 299  * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time.
300 300  
301 +
301 301  === 2.2.2 HEX format Payload(Type~=0) ===
302 302  
303 303  
... ... @@ -348,6 +348,7 @@
348 348  (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative)
349 349  
350 350  
352 +
351 351  (% style="color:blue" %)**Humidity:   **
352 352  
353 353  Read:0295(H)=661(D)    Value:  661 / 10=66.1, So 66.1%
... ... @@ -365,6 +365,7 @@
365 365  
366 366  Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard.
367 367  
370 +
368 368  (% style="color:#4472c4" %)**{"IMEI":866207053462762,"temperature":29.2,"humidity":54.2,"battery":3.27,"signal":24}**
369 369  
370 370  
... ... @@ -375,6 +375,7 @@
375 375  
376 376  Temperature, Humidity, Battery & Signal. This payload type only valid for ThingsSpeak Platform
377 377  
381 +
378 378  As below:
379 379  
380 380  (% style="color:#4472c4" %)**field1=27.9&field2=49.9&field3=3.23&field4=28**
... ... @@ -385,10 +385,12 @@
385 385  
386 386  By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8
387 387  
392 +
388 388  User can use below commands to change the (% style="color:blue" %)**uplink interval**.
389 389  
390 -(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s
395 +(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s
391 391  
397 +
392 392  User can also push the button for more than 1 seconds to activate an uplink.
393 393  
394 394  
... ... @@ -397,13 +397,13 @@
397 397  
398 398  To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
399 399  
400 -* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
406 +* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/  The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
401 401  
402 -* (% style="color:#037691" %)**AT+NOUD=8**     (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
408 +* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/   The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
403 403  
404 404  The diagram below explains the relationship between TR, NOUD, and TDC more clearly:
405 405  
406 -[[image:1692424376354-959.png]]
412 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png||alt="IMG_256"]]
407 407  
408 408  
409 409  == 2.5 Humidity and Temperature alarm function ==
... ... @@ -416,12 +416,12 @@
416 416  
417 417  (% style="color:#037691" %)**AT+ SHHUM=min,max**
418 418  
419 -Example: AT+ SHHUM=50,80  ~/~/ Alarm when humidity lower than 50 or higher than 80.
425 +Example: AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50 or higher than 80.
420 420  
421 421  
422 422  (% style="color:#037691" %)**AT+ SHTEMP=min,max**
423 423  
424 -Example: AT+ SHTEMP=20,30  ~/~/ Alarm when temperature lower than 20 or higher than 30
430 +Example: AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20 or higher than 30
425 425  
426 426  
427 427  (% style="color:red" %)**Notice:**
... ... @@ -430,6 +430,9 @@
430 430  
431 431  * If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.**
432 432  
439 +
440 +
441 +
433 433  == 2.6 Trggier an uplink by external interrupt ==
434 434  
435 435  
... ... @@ -437,16 +437,18 @@
437 437  
438 438  (% style="color:blue" %)**AT command:**
439 439  
440 -* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
449 +* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
441 441  
442 -* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/ Disable Interrupt
451 +* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/Disable Interrupt
443 443  
444 -* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/ Trigger by rising and falling edge
453 +* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/Trigger by rising and falling edge
445 445  
446 -* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/ Trigger by falling edge
455 +* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/Trigger by falling edge
447 447  
448 -* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
457 +* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/Trigger by rising edge
449 449  
459 +
460 +
450 450  = 3. Configure S31x-NB =
451 451  
452 452  == 3.1 Configure Methods ==
... ... @@ -458,161 +458,271 @@
458 458  
459 459  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
460 460  
461 -== 3.2 AT Commands Set ==
472 +* LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
462 462  
463 463  
464 -AT+<CMD>?        : Help on <CMD>
465 465  
466 -AT+<CMD>         : Run <CMD>
476 +== 3.2 General Commands ==
467 467  
468 -AT+<CMD>=<value> : Set the value
469 469  
470 -AT+<CMD>=?       : Get the value
479 +These commands are to configure:
471 471  
481 +* General system settings like: uplink interval.
482 +* LoRaWAN protocol & radio related command.
472 472  
473 -(% style="color:blue" %)**General Commands**      
484 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
474 474  
475 -AT                    : Attention       
486 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
476 476  
477 -AT?  : Short Help     
478 478  
479 -ATZ  : MCU Reset    
489 +== 3.3 Commands special design for S31x-LB ==
480 480  
481 -AT+TDC  : Application Data Transmission Interval
482 482  
483 -AT+CFG  : Print all configurations
492 +These commands only valid for S31x-LB, as below:
484 484  
485 -AT+CFGMOD           : Working mode selection
486 486  
487 -AT+DEUI  : Get or set the Device ID
495 +=== 3.3.1 Set Transmit Interval Time ===
488 488  
489 -AT+INTMOD            : Set the trigger interrupt mode
490 490  
491 -AT+5VT           : Set extend the time of 5V power  
498 +Feature: Change LoRaWAN End Node Transmit Interval.
492 492  
493 -AT+PRO          : Choose agreement
500 +(% style="color:blue" %)**AT Command: AT+TDC**
494 494  
495 -AT+RXDL  : Extend the sending and receiving time
502 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
503 +|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response**
504 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
505 +30000
506 +OK
507 +the interval is 30000ms = 30s
508 +)))
509 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
510 +OK
511 +Set transmit interval to 60000ms = 60 seconds
512 +)))
496 496  
497 -AT+DNSCFG  : Get or Set DNS Server
514 +(% style="color:blue" %)**Downlink Command: 0x01**
498 498  
499 -AT+GETSENSORVALUE   : Returns the current sensor measurement
516 +Format: Command Code (0x01) followed by 3 bytes time value.
500 500  
501 -AT+NOUD  : Get or Set the number of data to be uploaded
518 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
502 502  
503 -AT+CDP     : Read or Clear cached data
520 +* Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
521 +* Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
504 504  
505 -AT+SHTEMP:  Get or Set alarm of temp
523 +=== 3.3.2 Get Device Status ===
506 506  
507 -AT+SHHUM:  Get or Set alarm of moisture
508 508  
509 -AT+SERVADDR Server Address
526 +Send a LoRaWAN downlink to ask device send Alarm settings.
510 510  
528 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
511 511  
512 -(% style="color:blue" %)**UDP Management**
530 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
513 513  
514 -AT+CFM  :  Upload confirmation mode (only valid for UDP)
515 515  
533 +=== 3.3.3 Set Temperature Alarm Threshold ===
516 516  
517 -(% style="color:blue" %)**MQTT Management**
518 518  
519 -AT+CLIENT               : Get or Set MQTT client
536 +* (% style="color:blue" %)**AT Command:**
520 520  
521 -AT+UNAME              : Get or Set MQTT Username
538 +(% style="color:#037691" %)**AT+SHTEMP=min,max**
522 522  
523 -AT+PWD                  : Get or Set MQTT password
540 +* When min=0, and max≠0, Alarm higher than max
541 +* When min≠0, and max=0, Alarm lower than min
542 +* When min≠0 and max≠0, Alarm higher than max or lower than min
524 524  
525 -AT+PUBTOPIC  : Get or Set MQTT publish topic
544 +Example:
526 526  
527 -AT+SUBTOPIC  : Get or Set MQTT subscription topic
546 + AT+SHTEMP=0,30   ~/~/ Alarm when temperature higher than 30.
528 528  
548 +* (% style="color:blue" %)**Downlink Payload:**
529 529  
530 -(% style="color:blue" %)**Information**          
550 +(% style="color:#037691" %)**0x(0C 01 00 1E)**  (%%) ~/~/ Set AT+SHTEMP=0,30
531 531  
532 -AT+FDR  : Factory Data Reset
552 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)**
533 533  
534 -AT+PWORD  : Serial Access Password
535 535  
536 -AT+LDATA  : Get the last upload data
555 +=== 3.3.4 Set Humidity Alarm Threshold ===
537 537  
538 -AT+CDP  : Read or Clear cached data
539 539  
558 +* (% style="color:blue" %)**AT Command:**
540 540  
560 +(% style="color:#037691" %)**AT+SHHUM=min,max**
561 +
562 +* When min=0, and max≠0, Alarm higher than max
563 +* When min≠0, and max=0, Alarm lower than min
564 +* When min≠0 and max≠0, Alarm higher than max or lower than min
565 +
566 +Example:
567 +
568 + AT+SHHUM=70,0  ~/~/ Alarm when humidity lower than 70%.
569 +
570 +* (% style="color:blue" %)**Downlink Payload:**
571 +
572 +(% style="color:#037691" %)**0x(0C 02 46 00)**(%%)  ~/~/ Set AT+SHTHUM=70,0
573 +
574 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))**
575 +
576 +
577 +=== 3.3.5 Set Alarm Interval ===
578 +
579 +
580 +The shortest time of two Alarm packet. (unit: min)
581 +
582 +* (% style="color:blue" %)**AT Command:**
583 +
584 +(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes.
585 +
586 +* (% style="color:blue" %)**Downlink Payload:**
587 +
588 +(% style="color:#037691" %)**0x(0D 00 1E)**(%%)     **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes
589 +
590 +
591 +=== 3.3.6 Get Alarm settings ===
592 +
593 +
594 +Send a LoRaWAN downlink to ask device send Alarm settings.
595 +
596 +* (% style="color:#037691" %)**Downlink Payload:  **(%%)0x0E 01
597 +
598 +**Example:**
599 +
600 +[[image:image-20230524110211-4.png]]
601 +
602 +**Explain:**
603 +
604 +* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message.
605 +
606 +=== 3.3.7 Set Interrupt Mode ===
607 +
608 +
609 +Feature, Set Interrupt mode for PA8 of pin.
610 +
611 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
612 +
613 +(% style="color:blue" %)**AT Command: AT+INTMOD**
614 +
615 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
616 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
617 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
618 +0
619 +OK
620 +the mode is 0 =Disable Interrupt
621 +)))
622 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
623 +Set Transmit Interval
624 +0. (Disable Interrupt),
625 +~1. (Trigger by rising and falling edge)
626 +2. (Trigger by falling edge)
627 +3. (Trigger by rising edge)
628 +)))|(% style="width:157px" %)OK
629 +
630 +(% style="color:blue" %)**Downlink Command: 0x06**
631 +
632 +Format: Command Code (0x06) followed by 3 bytes.
633 +
634 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
635 +
636 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
637 +* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
638 +
639 +=== 3.3.8 Set Power Output Duration ===
640 +
641 +
642 +Control the output duration 5V . Before each sampling, device will
643 +
644 +~1. first enable the power output to external sensor,
645 +
646 +2. keep it on as per duration, read sensor value and construct uplink payload
647 +
648 +3. final, close the power output.
649 +
650 +(% style="color:blue" %)**AT Command: AT+5VT**
651 +
652 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
653 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
654 +|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default)
655 +OK
656 +|(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK
657 +
658 +(% style="color:blue" %)**Downlink Command: 0x07**
659 +
660 +Format: Command Code (0x07) followed by 2 bytes.
661 +
662 +The first and second bytes are the time to turn on.
663 +
664 +* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
665 +* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
666 +
541 541  = 4. Battery & Power Consumption =
542 542  
543 543  
544 -S31x-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
670 +S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
545 545  
546 546  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
547 547  
548 548  
549 -= 5. Firmware update =
675 += 5. OTA Firmware update =
550 550  
551 551  
552 -User can change device firmware to::
678 +(% class="wikigeneratedid" %)
679 +User can change firmware S31x-LB to:
553 553  
681 +* Change Frequency band/ region.
554 554  * Update with new features.
555 -
556 556  * Fix bugs.
557 557  
558 -Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/fhb3uyl4gt6clru/AAAiZVTFcxrfE1JOOyfcgO9ha?dl=0]]**
685 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0]]**
559 559  
687 +
560 560  Methods to Update Firmware:
561 561  
562 -* (Recommended way) OTA firmware update via BLE: [[**Instruction**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE_Firmware_Update_NB_Sensors_BC660K-GL/]].
563 -
690 +* (Recommanded way) OTA firmware update via wireless : **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
564 564  * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
565 565  
566 -
567 -
568 568  = 6. FAQ =
569 569  
570 -== 6.1 How can I access t BC660K-GL AT Commands? ==
571 571  
572 572  
573 -User can access to BC660K-GL directly and send AT Commands.
697 += 7. Order Info =
574 574  
575 -[[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
576 576  
700 +Part Number: (% style="color:blue" %)**S31-LB-XX  / S31B-LB-XX**
577 577  
702 +(% style="color:red" %)**XX**(%%): The default frequency band
578 578  
579 -= 7. Order Info =
704 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
580 580  
706 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
581 581  
582 -Part Number: (% style="color:blue" %)**S31-NB-XX  / S31B-NB-XX**
708 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
583 583  
584 -(% style="color:red" %)**XX**(%%):
710 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
585 585  
586 -* (% style="color:#037691" %)**GE**(%%): General version ( Exclude SIM card)
712 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
587 587  
588 -* (% style="color:#037691" %)**1D**(%%): with 1NCE* 10 years 500MB SIM card and Pre-configure to DataCake server
714 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
589 589  
590 -(% style="color:#037691" %)**~* 1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands
716 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band
591 591  
718 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
592 592  
593 -
594 594  = 8. ​Packing Info =
595 595  
596 596  
597 597  (% style="color:#037691" %)**Package Includes**:
598 598  
599 -* S31-NB or S31-NB NB-IoT Sensor Node x 1
725 +* S31x-LB LoRaWAN Temperature & Humidity Sensor
600 600  
601 -* External antenna x 1
602 -
603 -
604 -
605 605  (% style="color:#037691" %)**Dimension and weight**:
606 606  
607 -* Device Size: 13.0 x 5 x 4.5 cm
729 +* Device Size: cm
608 608  
609 -* Device Weight: 150g
731 +* Device Weight: g
610 610  
611 -* Package Size / pcs : 14.0 x 8x 5 cm
733 +* Package Size / pcs : cm
612 612  
613 -* Weight / pcs : 180g
735 +* Weight / pcs : g