Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -348,6 +348,7 @@ 348 348 (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative) 349 349 350 350 351 + 351 351 (% style="color:blue" %)**Humidity: ** 352 352 353 353 Read:0295(H)=661(D) Value: 661 / 10=66.1, So 66.1% ... ... @@ -397,9 +397,9 @@ 397 397 398 398 To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 399 399 400 -* (% style="color:#037691" %)**AT+TR=900** (%%) 401 +* (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 401 401 402 -* (% style="color:#037691" %)**AT+NOUD=8** 403 +* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 403 403 404 404 The diagram below explains the relationship between TR, NOUD, and TDC more clearly: 405 405 ... ... @@ -416,12 +416,12 @@ 416 416 417 417 (% style="color:#037691" %)**AT+ SHHUM=min,max** 418 418 419 -Example: AT+ SHHUM=50,80 420 +Example: AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50 or higher than 80. 420 420 421 421 422 422 (% style="color:#037691" %)**AT+ SHTEMP=min,max** 423 423 424 -Example: AT+ SHTEMP=20,30 425 +Example: AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20 or higher than 30 425 425 426 426 427 427 (% style="color:red" %)**Notice:** ... ... @@ -430,6 +430,8 @@ 430 430 431 431 * If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.** 432 432 434 + 435 + 433 433 == 2.6 Trggier an uplink by external interrupt == 434 434 435 435 ... ... @@ -437,16 +437,17 @@ 437 437 438 438 (% style="color:blue" %)**AT command:** 439 439 440 -* (% style="color:#037691" %)**AT+INTMOD **(%%) 443 +* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode 441 441 442 -* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/ 445 +* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/Disable Interrupt 443 443 444 -* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) 447 +* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/Trigger by rising and falling edge 445 445 446 -* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) 449 +* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/Trigger by falling edge 447 447 448 -* (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ 451 +* (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/Trigger by rising edge 449 449 453 + 450 450 = 3. Configure S31x-NB = 451 451 452 452 == 3.1 Configure Methods == ... ... @@ -458,139 +458,253 @@ 458 458 459 459 * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]. 460 460 461 - ==3.2ATCommands Set==465 +* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 462 462 463 463 464 - AT+<CMD>?: Helpon<CMD>468 +== 3.2 General Commands == 465 465 466 -AT+<CMD> : Run <CMD> 467 467 468 - AT+<CMD>=<value>: Setthevalue471 +These commands are to configure: 469 469 470 -AT+<CMD>=? : Get the value 473 +* General system settings like: uplink interval. 474 +* LoRaWAN protocol & radio related command. 471 471 476 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 472 472 473 - (% style="color:blue"%)**Generals**478 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 474 474 475 -AT : Attention 476 476 477 - AT?: ShortHelp481 +== 3.3 Commands special design for S31x-LB == 478 478 479 -ATZ : MCU Reset 480 480 481 - AT+TDC: ApplicationDataTransmissionInterval484 +These commands only valid for S31x-LB, as below: 482 482 483 -AT+CFG : Print all configurations 484 484 485 - AT+CFGMOD:Workingmodeselection487 +=== 3.3.1 Set Transmit Interval Time === 486 486 487 -AT+DEUI : Get or set the Device ID 488 488 489 - AT+INTMOD : Setthetriggerinterruptmode490 +Feature: Change LoRaWAN End Node Transmit Interval. 490 490 491 - AT+5VT: Setxtendthetimeof 5V power492 +(% style="color:blue" %)**AT Command: AT+TDC** 492 492 493 -AT+PRO : Choose agreement 494 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 495 +|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response** 496 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 497 +30000 498 +OK 499 +the interval is 30000ms = 30s 500 +))) 501 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 502 +OK 503 +Set transmit interval to 60000ms = 60 seconds 504 +))) 494 494 495 - AT+RXDL: Extend thesendingandreceiving time506 +(% style="color:blue" %)**Downlink Command: 0x01** 496 496 497 - AT+DNSCFG:GetorSetDNSServer508 +Format: Command Code (0x01) followed by 3 bytes time value. 498 498 499 - AT+GETSENSORVALUE: Returns thecurrentsensormeasurement510 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 500 500 501 -AT+NOUD : Get or Set the number of data to be uploaded 512 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 513 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 502 502 503 - AT+CDP:Reador Clearcacheddata515 +=== 3.3.2 Get Device Status === 504 504 505 -AT+SHTEMP: Get or Set alarm of temp 506 506 507 - AT+SHHUM:GetorSet alarmof moisture518 +Send a LoRaWAN downlink to ask device send Alarm settings. 508 508 509 - AT+SERVADDR: ServerAddress520 +(% style="color:blue" %)**Downlink Payload: **(%%)0x26 01 510 510 522 +Sensor will upload Device Status via FPORT=5. See payload section for detail. 511 511 512 -(% style="color:blue" %)**UDP Management** 513 513 514 - AT+CFM:Upload confirmationmode(only validfor UDP)525 +=== 3.3.3 Set Temperature Alarm Threshold === 515 515 516 516 517 -(% style="color:blue" %)** MQTTManagement**528 +* (% style="color:blue" %)**AT Command:** 518 518 519 - AT+CLIENT: Getet MQTT client530 +(% style="color:#037691" %)**AT+SHTEMP=min,max** 520 520 521 -AT+UNAME : Get or Set MQTT Username 532 +* When min=0, and max≠0, Alarm higher than max 533 +* When min≠0, and max=0, Alarm lower than min 534 +* When min≠0 and max≠0, Alarm higher than max or lower than min 522 522 523 - AT+PWD : Get or Set MQTT password536 +Example: 524 524 525 -AT+ PUBTOPIC: GetorSetMQTT publish topic538 + AT+SHTEMP=0,30 ~/~/ Alarm when temperature higher than 30. 526 526 527 - AT+SUBTOPIC: GetSetMQTT subscriptiontopic540 +* (% style="color:blue" %)**Downlink Payload:** 528 528 542 +(% style="color:#037691" %)**0x(0C 01 00 1E)** (%%) ~/~/ Set AT+SHTEMP=0,30 529 529 530 -(% style="color: blue" %)**Information**544 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)** 531 531 532 -AT+FDR : Factory Data Reset 533 533 534 - AT+PWORD:SerialAccess Password547 +=== 3.3.4 Set Humidity Alarm Threshold === 535 535 536 -AT+LDATA : Get the last upload data 537 537 538 - AT+CDP: ReadorClearcacheddata550 +* (% style="color:blue" %)**AT Command:** 539 539 552 +(% style="color:#037691" %)**AT+SHHUM=min,max** 540 540 554 +* When min=0, and max≠0, Alarm higher than max 555 +* When min≠0, and max=0, Alarm lower than min 556 +* When min≠0 and max≠0, Alarm higher than max or lower than min 557 + 558 +Example: 559 + 560 + AT+SHHUM=70,0 ~/~/ Alarm when humidity lower than 70%. 561 + 562 +* (% style="color:blue" %)**Downlink Payload:** 563 + 564 +(% style="color:#037691" %)**0x(0C 02 46 00)**(%%) ~/~/ Set AT+SHTHUM=70,0 565 + 566 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))** 567 + 568 + 569 +=== 3.3.5 Set Alarm Interval === 570 + 571 + 572 +The shortest time of two Alarm packet. (unit: min) 573 + 574 +* (% style="color:blue" %)**AT Command:** 575 + 576 +(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes. 577 + 578 +* (% style="color:blue" %)**Downlink Payload:** 579 + 580 +(% style="color:#037691" %)**0x(0D 00 1E)**(%%) **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes 581 + 582 + 583 +=== 3.3.6 Get Alarm settings === 584 + 585 + 586 +Send a LoRaWAN downlink to ask device send Alarm settings. 587 + 588 +* (% style="color:#037691" %)**Downlink Payload: **(%%)0x0E 01 589 + 590 +**Example:** 591 + 592 +[[image:image-20230524110211-4.png]] 593 + 594 +**Explain:** 595 + 596 +* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 597 + 598 +=== 3.3.7 Set Interrupt Mode === 599 + 600 + 601 +Feature, Set Interrupt mode for PA8 of pin. 602 + 603 +When AT+INTMOD=0 is set, PA8 is used as a digital input port. 604 + 605 +(% style="color:blue" %)**AT Command: AT+INTMOD** 606 + 607 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 608 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 609 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 610 +0 611 +OK 612 +the mode is 0 =Disable Interrupt 613 +))) 614 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 615 +Set Transmit Interval 616 +0. (Disable Interrupt), 617 +~1. (Trigger by rising and falling edge) 618 +2. (Trigger by falling edge) 619 +3. (Trigger by rising edge) 620 +)))|(% style="width:157px" %)OK 621 + 622 +(% style="color:blue" %)**Downlink Command: 0x06** 623 + 624 +Format: Command Code (0x06) followed by 3 bytes. 625 + 626 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 627 + 628 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 629 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 630 + 631 +=== 3.3.8 Set Power Output Duration === 632 + 633 + 634 +Control the output duration 5V . Before each sampling, device will 635 + 636 +~1. first enable the power output to external sensor, 637 + 638 +2. keep it on as per duration, read sensor value and construct uplink payload 639 + 640 +3. final, close the power output. 641 + 642 +(% style="color:blue" %)**AT Command: AT+5VT** 643 + 644 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 645 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response** 646 +|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default) 647 +OK 648 +|(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK 649 + 650 +(% style="color:blue" %)**Downlink Command: 0x07** 651 + 652 +Format: Command Code (0x07) followed by 2 bytes. 653 + 654 +The first and second bytes are the time to turn on. 655 + 656 +* Example 1: Downlink Payload: 070000 **~-~-->** AT+5VT=0 657 +* Example 2: Downlink Payload: 0701F4 **~-~-->** AT+5VT=500 658 + 541 541 = 4. Battery & Power Consumption = 542 542 543 543 544 -S31x- NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.662 +S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 545 545 546 546 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 547 547 548 548 549 -= 5. Firmware update = 667 += 5. OTA Firmware update = 550 550 551 551 552 -User can change device firmware to:: 670 +(% class="wikigeneratedid" %) 671 +User can change firmware S31x-LB to: 553 553 673 +* Change Frequency band/ region. 554 554 * Update with new features. 555 - 556 556 * Fix bugs. 557 557 558 -Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/f hb3uyl4gt6clru/AAAiZVTFcxrfE1JOOyfcgO9ha?dl=0]]**677 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0]]** 559 559 679 + 560 560 Methods to Update Firmware: 561 561 562 -* (Recommended way) OTA firmware update via BLE: [[**Instruction**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE_Firmware_Update_NB_Sensors_BC660K-GL/]]. 563 - 682 +* (Recommanded way) OTA firmware update via wireless : **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]** 564 564 * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**. 565 565 566 - 567 - 568 568 = 6. FAQ = 569 569 570 -== 6.1 How can I access t BC660K-GL AT Commands? == 571 571 572 572 573 - Usercanaccess to BC660K-GL directly andsendAT Commands.689 += 7. Order Info = 574 574 575 -[[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 576 576 692 +Part Number: (% style="color:blue" %)**S31-LB-XX / S31B-LB-XX** 577 577 694 +(% style="color:red" %)**XX**(%%): The default frequency band 578 578 579 - =7.OrderInfo=696 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 580 580 698 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 581 581 582 - PartNumber:(% style="color:blue" %)**S31-NB-XX / S31B-NB-XX**700 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 583 583 584 -(% style="color:red" %)** XX**(%%):702 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 585 585 586 -* (% style="color: #037691" %)**GE**(%%):Generalversion( Exclude SIM card)704 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 587 587 588 -* (% style="color: #037691" %)**1D**(%%):with 1NCE*10 years500MBSIM card andPre-configure to DataCake server706 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 589 589 590 -(% style="color: #037691" %)**~* 1NCE SIM CardNB-IoT network coverage**(%%):Austria, Belgium, Bulgaria, Croatia, CzechRepublic, Denmark,Finland, Germany, Great Britain, Greece, Hungary,Ireland, Italy, Latvia, Malta,Netherlands,Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands708 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 591 591 710 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 592 592 593 - 594 594 = 8. Packing Info = 595 595 596 596