... ... @@ -299,6 +299,7 @@
299 299  * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time.
300 300  
301 301  
302 +
302 302  === 2.2.2 HEX format Payload(Type~=0) ===
303 303  
304 304  
... ... @@ -400,7 +400,7 @@
400 400  
401 401  * (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
402 402  
403 -* (% style="color:#037691" %)**AT+NOUD=8**     (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
404 +* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
404 404  
405 405  The diagram below explains the relationship between TR, NOUD, and TDC more clearly:
406 406  
... ... @@ -432,6 +432,7 @@
432 432  * If user only want to send only min or max, user can set the alarm to a value that device won’t reach. For example: (% style="color:#037691" %)**AT+SHTEMP=-80,0.**
433 433  
434 434  
436 +
435 435  == 2.6 Trggier an uplink by external interrupt ==
436 436  
437 437  
... ... @@ -449,6 +449,7 @@
449 449  
450 450  * (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
451 451  
454 +
452 452  = 3. Configure S31x-NB =
453 453  
454 454  == 3.1 Configure Methods ==
... ... @@ -460,108 +460,224 @@
460 460  
461 461  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
462 462  
463 -== 3.2 AT Commands Set ==
466 +* AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
467 +* AT Command via UART Connection : See [[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20NB%20ST-BC660K-GL%20base%20model%20%28for%20AT%20Commands%2C%20firmware%20upgrade%29/]].
464 464  
469 +== 3.2 General Commands ==
465 465  
466 -AT+<CMD>?        : Help on <CMD>
467 467  
468 -AT+<CMD>         : Run <CMD>
472 +These commands are to configure:
469 469  
470 -AT+<CMD>=<value> : Set the value
474 +* General system settings like: uplink interval.
475 +* LoRaWAN protocol & radio related command.
471 471  
472 -AT+<CMD>=?       : Get the value
477 +They are same for all Dragino Devices which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
473 473  
479 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
474 474  
475 -(% style="color:blue" %)**General Commands**      
476 476  
477 -AT                    : Attention       
482 +== 3.3 Commands special design for S31x-LB ==
478 478  
479 -AT?  : Short Help     
480 480  
481 -AT : MCU Reset    
485 +These commands only valid for S31x-LB, as below:
482 482  
483 -AT+TDC  : Application Data Transmission Interval
484 484  
485 -AT+CFG  : Print all configurations
488 +=== 3.3.1 Set Transmit Interval Time ===
486 486  
487 -AT+CFGMOD           : Working mode selection
488 488  
489 -AT+DEUI  : Get or set the Device ID
491 +Feature: Change LoRaWAN End Node Transmit Interval.
490 490  
491 -AT+INTMOD            : Set the trigger interrupt mode
493 +(% style="color:blue" %)**AT Command: AT+TDC**
492 492  
493 -AT+5VT           : Set extend the time of 5V power  
495 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
496 +|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="background-color:#D9E2F3;color:#0070C0" %)**Response**
497 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
498 +30000
499 +OK
500 +the interval is 30000ms = 30s
501 +)))
502 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
503 +OK
504 +Set transmit interval to 60000ms = 60 seconds
505 +)))
494 494  
495 -AT+PRO          : Choose agreement
507 +(% style="color:blue" %)**Downlink Command: 0x01**
496 496  
497 -AT+RXDL  : Extend the sending and receiving time
509 +Format: Command Code (0x01) followed by 3 bytes time value.
498 498  
499 -AT+DNSCFG  : Get or Set DNS Server
511 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
500 500  
501 -AT+GETSENSORVALUE   : Returns the current sensor measurement
513 +* Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
514 +* Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
502 502  
503 -AT+NOUD  : Get or Set the number of data to be uploaded
516 +=== 3.3.2 Get Device Status ===
504 504  
505 -AT+CDP     : Read or Clear cached data
506 506  
507 -AT+SHTEMP:  Get or Set alarm of temp
519 +Send a LoRaWAN downlink to ask device send Alarm settings.
508 508  
509 -AT+SHHUM:  Get or Set alarm of moisture
521 +(% style="color:blue" %)**Downlink Payload:  **(%%)0x26 01
510 510  
511 -AT+SERVADDR Server Address
523 +Sensor will upload Device Status via FPORT=5. See payload section for detail.
512 512  
513 513  
514 -(% style="color:blue" %)**UDP Management**
526 +=== 3.3.3 Set Temperature Alarm Threshold ===
515 515  
516 -AT+CFM  :  Upload confirmation mode (only valid for UDP)
517 517  
529 +* (% style="color:blue" %)**AT Command:**
518 518  
519 -(% style="color:blue" %)**MQTT Management**
531 +(% style="color:#037691" %)**AT+SHTEMP=min,max**
520 520  
521 -AT+CLIENT               : Get or Set MQTT client
533 +* When min=0, and max≠0, Alarm higher than max
534 +* When min≠0, and max=0, Alarm lower than min
535 +* When min≠0 and max≠0, Alarm higher than max or lower than min
522 522  
523 -AT+UNAME              : Get or Set MQTT Username
537 +Example:
524 524  
525 -AT+PWD                  : Get or Set MQTT password
539 + AT+SHTEMP=0,30   ~/~/ Alarm when temperature higher than 30.
526 526  
527 -AT+PUBTOPIC  : Get or Set MQTT publish topic
541 +* (% style="color:blue" %)**Downlink Payload:**
528 528  
529 -AT+SUBTOPIC  : Get or Set MQTT subscription topic
543 +(% style="color:#037691" %)**0x(0C 01 00 1E)**  (%%) ~/~/ Set AT+SHTEMP=0,30
530 530  
545 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x00 for low limit(not set), 4^^th^^ byte = 0x1E for high limit: 30)**
531 531  
532 -(% style="color:blue" %)**Information**          
533 533  
534 -AT+FDR  : Factory Data Reset
548 +=== 3.3.4 Set Humidity Alarm Threshold ===
535 535  
536 -AT+PWORD  : Serial Access Password
537 537  
538 -AT+LDATA  : Get the last upload data
551 +* (% style="color:blue" %)**AT Command:**
539 539  
540 -AT+CDP  : Read or Clear cached data
553 +(% style="color:#037691" %)**AT+SHHUM=min,max**
541 541  
555 +* When min=0, and max≠0, Alarm higher than max
556 +* When min≠0, and max=0, Alarm lower than min
557 +* When min≠0 and max≠0, Alarm higher than max or lower than min
542 542  
559 +Example:
560 +
561 + AT+SHHUM=70,0  ~/~/ Alarm when humidity lower than 70%.
562 +
563 +* (% style="color:blue" %)**Downlink Payload:**
564 +
565 +(% style="color:#037691" %)**0x(0C 02 46 00)**(%%)  ~/~/ Set AT+SHTHUM=70,0
566 +
567 +(% style="color:red" %)**(note: 3^^rd^^ byte= 0x46 for low limit (70%), 4^^th^^ byte = 0x00 for high limit (not set))**
568 +
569 +
570 +=== 3.3.5 Set Alarm Interval ===
571 +
572 +
573 +The shortest time of two Alarm packet. (unit: min)
574 +
575 +* (% style="color:blue" %)**AT Command:**
576 +
577 +(% style="color:#037691" %)**AT+ATDC=30** (%%) ~/~/ The shortest interval of two Alarm packets is 30 minutes, Means is there is an alarm packet uplink, there won't be another one in the next 30 minutes.
578 +
579 +* (% style="color:blue" %)**Downlink Payload:**
580 +
581 +(% style="color:#037691" %)**0x(0D 00 1E)**(%%)     **~-~--> ** Set AT+ATDC=0x 00 1E = 30 minutes
582 +
583 +
584 +=== 3.3.6 Get Alarm settings ===
585 +
586 +
587 +Send a LoRaWAN downlink to ask device send Alarm settings.
588 +
589 +* (% style="color:#037691" %)**Downlink Payload:  **(%%)0x0E 01
590 +
591 +**Example:**
592 +
593 +[[image:image-20230524110211-4.png]]
594 +
595 +**Explain:**
596 +
597 +* Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message.
598 +
599 +=== 3.3.7 Set Interrupt Mode ===
600 +
601 +
602 +Feature, Set Interrupt mode for PA8 of pin.
603 +
604 +When AT+INTMOD=0 is set, PA8 is used as a digital input port.
605 +
606 +(% style="color:blue" %)**AT Command: AT+INTMOD**
607 +
608 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
609 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
610 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
611 +0
612 +OK
613 +the mode is 0 =Disable Interrupt
614 +)))
615 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
616 +Set Transmit Interval
617 +0. (Disable Interrupt),
618 +~1. (Trigger by rising and falling edge)
619 +2. (Trigger by falling edge)
620 +3. (Trigger by rising edge)
621 +)))|(% style="width:157px" %)OK
622 +
623 +(% style="color:blue" %)**Downlink Command: 0x06**
624 +
625 +Format: Command Code (0x06) followed by 3 bytes.
626 +
627 +This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
628 +
629 +* Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
630 +* Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
631 +
632 +=== 3.3.8 Set Power Output Duration ===
633 +
634 +
635 +Control the output duration 5V . Before each sampling, device will
636 +
637 +~1. first enable the power output to external sensor,
638 +
639 +2. keep it on as per duration, read sensor value and construct uplink payload
640 +
641 +3. final, close the power output.
642 +
643 +(% style="color:blue" %)**AT Command: AT+5VT**
644 +
645 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
646 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Response**
647 +|(% style="width:154px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:157px" %)0 (default)
648 +OK
649 +|(% style="width:154px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:157px" %)OK
650 +
651 +(% style="color:blue" %)**Downlink Command: 0x07**
652 +
653 +Format: Command Code (0x07) followed by 2 bytes.
654 +
655 +The first and second bytes are the time to turn on.
656 +
657 +* Example 1: Downlink Payload: 070000  **~-~-->**  AT+5VT=0
658 +* Example 2: Downlink Payload: 0701F4  **~-~-->**  AT+5VT=500
659 +
543 543  = 4. Battery & Power Consumption =
544 544  
545 545  
546 -S31x-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
663 +S31x-LB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
547 547  
548 548  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
549 549  
550 550  
551 -= 5. Firmware update =
668 += 5. OTA Firmware update =
552 552  
553 553  
554 -User can change device firmware to::
671 +(% class="wikigeneratedid" %)
672 +User can change firmware S31x-LB to:
555 555  
674 +* Change Frequency band/ region.
556 556  * Update with new features.
557 -
558 558  * Fix bugs.
559 559  
560 -Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/fhb3uyl4gt6clru/AAAiZVTFcxrfE1JOOyfcgO9ha?dl=0]]**
678 +Firmware and changelog can be downloaded from : **[[Firmware download link>>https://www.dropbox.com/sh/fis3g6nmhv0eokg/AAC6BcCZaX4BdqZkduUvZ3jIa?dl=0]]**
561 561  
680 +
562 562  Methods to Update Firmware:
563 563  
564 -* (Recommended way) OTA firmware update via BLE: [[**Instruction**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE_Firmware_Update_NB_Sensors_BC660K-GL/]].
683 +* (Recommanded way) OTA firmware update via wireless **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**
565 565  * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
566 566  
567 567  = 6. FAQ =