... ... @@ -299,6 +299,7 @@
299 299  * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Temperature, Humidity, Sampling time.
300 300  
301 301  
302 +
302 302  === 2.2.2 HEX format Payload(Type~=0) ===
303 303  
304 304  
... ... @@ -349,7 +349,6 @@
349 349  (FF3F & 8000:Judge whether the highest bit is 1, when the highest bit is 1, it is negative)
350 350  
351 351  
352 -
353 353  (% style="color:blue" %)**Humidity:   **
354 354  
355 355  Read:0295(H)=661(D)    Value:  661 / 10=66.1, So 66.1%
... ... @@ -367,7 +367,6 @@
367 367  
368 368  Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard.
369 369  
370 -
371 371  (% style="color:#4472c4" %)**{"IMEI":866207053462762,"temperature":29.2,"humidity":54.2,"battery":3.27,"signal":24}**
372 372  
373 373  
... ... @@ -378,7 +378,6 @@
378 378  
379 379  Temperature, Humidity, Battery & Signal. This payload type only valid for ThingsSpeak Platform
380 380  
381 -
382 382  As below:
383 383  
384 384  (% style="color:#4472c4" %)**field1=27.9&field2=49.9&field3=3.23&field4=28**
... ... @@ -389,12 +389,10 @@
389 389  
390 390  By default, Sensor will send uplinks (% style="color:blue" %)**every 2 hours**(%%) & AT+NOUD=8
391 391  
392 -
393 393  User can use below commands to change the (% style="color:blue" %)**uplink interval**.
394 394  
395 -(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s
392 +(% style="color:#037691" %)**AT+TDC=600 ** (%%) ~/~/ Set Update Interval to 600s
396 396  
397 -
398 398  User can also push the button for more than 1 seconds to activate an uplink.
399 399  
400 400  
... ... @@ -403,13 +403,13 @@
403 403  
404 404  To save battery life, S31-NB will sample temperature & humidity data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
405 405  
406 -* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/  The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
402 +* (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
407 407  
408 -* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/   The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
404 +* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
409 409  
410 410  The diagram below explains the relationship between TR, NOUD, and TDC more clearly:
411 411  
412 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png||alt="IMG_256"]]
408 +[[image:1692424376354-959.png]]
413 413  
414 414  
415 415  == 2.5 Humidity and Temperature alarm function ==
... ... @@ -422,12 +422,12 @@
422 422  
423 423  (% style="color:#037691" %)**AT+ SHHUM=min,max**
424 424  
425 -Example: AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50 or higher than 80.
421 +Example: AT+ SHHUM=50,80  ~/~/ Alarm when humidity lower than 50 or higher than 80.
426 426  
427 427  
428 428  (% style="color:#037691" %)**AT+ SHTEMP=min,max**
429 429  
430 -Example: AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20 or higher than 30
426 +Example: AT+ SHTEMP=20,30  ~/~/ Alarm when temperature lower than 20 or higher than 30
431 431  
432 432  
433 433  (% style="color:red" %)**Notice:**
... ... @@ -438,7 +438,6 @@
438 438  
439 439  
440 440  
441 -
442 442  == 2.6 Trggier an uplink by external interrupt ==
443 443  
444 444  
... ... @@ -446,18 +446,17 @@
446 446  
447 447  (% style="color:blue" %)**AT command:**
448 448  
449 -* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
444 +* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
450 450  
451 -* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/Disable Interrupt
446 +* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/ Disable Interrupt
452 452  
453 -* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/Trigger by rising and falling edge
448 +* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/ Trigger by rising and falling edge
454 454  
455 -* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/Trigger by falling edge
450 +* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/ Trigger by falling edge
456 456  
457 -* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/Trigger by rising edge
452 +* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
458 458  
459 459  
460 -
461 461  = 3. Configure S31x-NB =
462 462  
463 463  == 3.1 Configure Methods ==
... ... @@ -472,7 +472,6 @@
472 472  * LoRaWAN Downlink.  Instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
473 473  
474 474  
475 -
476 476  == 3.2 General Commands ==
477 477  
478 478