... ... @@ -440,8 +440,6 @@
440 440  == 2.4 Multi-Samplings and One uplink ==
441 441  
442 442  
443 -(% style="color:red" %)**Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]].**
444 -
445 445  To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
446 446  
447 447  * (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
... ... @@ -749,9 +749,11 @@
749 749  0xA6 02 00 00 32  ==>  AT+SETCNT=2,50
750 750  
751 751  
752 -== 2.14 Clock logging (Since firmware version v1.2.1) ==
753 753  
754 754  
752 +
753 +== 2.14 Clock logging (Since firmware version v1.2.1) ==
754 +
755 755  Sometimes when we deploy lots of end nodes in field. We want all sensors sample data at the same time, and upload these data together for analyze. In such case, we can use clock loging feature.
756 756  
757 757  We can use this command to set the start time of data recording and the time interval to meet the requirements of the specific collection time of data.
... ... @@ -760,7 +760,7 @@
760 760  
761 761  (% style="color:blue" %)**a:**(%%)** 0:** Disable Clock logging.  ** 1: **Enable Clock Logging
762 762  
763 -(% style="color:blue" %)**b:**(%%)** **Specify First sampling start second: range **(0 ~~ 3599, 65535)   ** ~/~/ (% style="color:red" %)**Note:**(%%)** **If parameter b is set to 65535, the log period starts after the node accesses the network and sends packets.
763 +(% style="color:blue" %)**b:**(%%)** **Specify First sampling start second: range **(0 ~~ 3599, 65535)   ** ~/~/**Note: **If parameter b is set to 65535, the log period starts after the node accesses the network and sends packets.
764 764  
765 765  (% style="color:blue" %)**c:**(%%)** **Specify the sampling interval: range **(0 ~~ 255 minutes)**
766 766  
... ... @@ -781,9 +781,11 @@
781 781  (% style="color:red" %)**Note: Users need to synchronize the server time before configuring this command. If the server time is not synchronized before this command is configured, the command takes effect only after the node is reset.**
782 782  
783 783  
784 -== 2.15 Example Query saved historical records ==
785 785  
786 786  
786 +
787 +== 2.8 Example Query saved historical records ==
788 +
787 787  * (% style="color:blue" %)**AT Command: AT+CDP**
788 788  
789 789  This command can be used to search the saved history, recording up to 32 groups of data, each group of historical data contains a maximum of 100 bytes.
... ... @@ -792,28 +792,11 @@
792 792  [[image:image-20240316151014-2.png||height="632" width="825"]]
793 793  
794 794  
795 -== 2.16 Uplink log query ==
796 796  
797 797  
798 -* (% style="color:blue" %)**AT Command: AT+GETLOG**
799 799  
800 -This command can be used to query upstream logs of data packets.
801 801  
802 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-NB-NA_NB-IoT_Analog_Sensor_User_Manual/WebHome/image-20240407191922-2.png?width=903&height=631&rev=1.1||alt="image-20240407191922-2.png"]]
803 803  
804 -
805 -== 2.17 Scheduled domain name resolution ==
806 -
807 -
808 -This command is used to set up scheduled domain name resolution.
809 -
810 -(% style="color:blue" %)**AT command:**
811 -
812 -* (% style="color:#037691" %)**AT+DNSTIMER=XX   **(%%)~/~/ Unit: hour
813 -
814 -After setting this command, domain name resolution will be performed regularly.
815 -
816 -
817 817  = 3. Configure DS03A-NB =
818 818  
819 819  == 3.1 Configure Methods ==
... ... @@ -877,6 +877,11 @@
877 877  AT+SERVADDR :  Server Address
878 878  
879 879  
865 +(% style="color:blue" %)**UDP Management**
866 +
867 +AT+CFM  :  Upload confirmation mode (only valid for UDP)
868 +
869 +
880 880  (% style="color:blue" %)**MQTT Management**
881 881  
882 882  AT+CLIENT               : Get or Set MQTT client
... ... @@ -929,7 +929,7 @@
929 929  
930 930  = 6. FAQ =
931 931  
932 -== 6.1 How can I access the BC660K-GL AT Commands? ==
922 +== 6.1 How can I access t BC660K-GL AT Commands? ==
933 933  
934 934  
935 935  User can access to BC660K-GL directly and send AT Commands.
... ... @@ -937,13 +937,6 @@
937 937  [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
938 938  
939 939  
940 -== 6.2 How to configure the certificate? ==
941 -
942 -
943 -User can can refer to this [[description>>url:http://wiki.dragino.com/xwiki/bin/view/How%20to%20configure%20the%20certificate%3F/]] to configure the certificate.
944 -
945 -
946 -
947 947  = 7. Order Info =
948 948  