Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
From version 140.1
edited by Mengting Qiu
on 2024/05/20 15:02
on 2024/05/20 15:02
Change comment:
There is no comment for this version
To version 137.1
edited by Mengting Qiu
on 2024/03/16 15:10
on 2024/03/16 15:10
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -440,8 +440,6 @@ 440 440 == 2.4 Multi-Samplings and One uplink == 441 441 442 442 443 -(% style="color:red" %)**Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]].** 444 - 445 445 To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 446 446 447 447 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) ... ... @@ -749,9 +749,11 @@ 749 749 0xA6 02 00 00 32 ==> AT+SETCNT=2,50 750 750 751 751 752 -== 2.14 Clock logging (Since firmware version v1.2.1) == 753 753 754 754 752 + 753 +== 2.14 Clock logging (Since firmware version v1.2.1) == 754 + 755 755 Sometimes when we deploy lots of end nodes in field. We want all sensors sample data at the same time, and upload these data together for analyze. In such case, we can use clock loging feature. 756 756 757 757 We can use this command to set the start time of data recording and the time interval to meet the requirements of the specific collection time of data. ... ... @@ -760,7 +760,7 @@ 760 760 761 761 (% style="color:blue" %)**a:**(%%)** 0:** Disable Clock logging. ** 1: **Enable Clock Logging 762 762 763 -(% style="color:blue" %)**b:**(%%)** **Specify First sampling start second: range **(0 ~~ 3599, 65535) ** ~/~/ (% style="color:red" %)**Note:**(%%)****If parameter b is set to 65535, the log period starts after the node accesses the network and sends packets.763 +(% style="color:blue" %)**b:**(%%)** **Specify First sampling start second: range **(0 ~~ 3599, 65535) ** ~/~/**Note: **If parameter b is set to 65535, the log period starts after the node accesses the network and sends packets. 764 764 765 765 (% style="color:blue" %)**c:**(%%)** **Specify the sampling interval: range **(0 ~~ 255 minutes)** 766 766 ... ... @@ -781,9 +781,11 @@ 781 781 (% style="color:red" %)**Note: Users need to synchronize the server time before configuring this command. If the server time is not synchronized before this command is configured, the command takes effect only after the node is reset.** 782 782 783 783 784 -== 2.15 Example Query saved historical records == 785 785 786 786 786 + 787 +== 2.8 Example Query saved historical records == 788 + 787 787 * (% style="color:blue" %)**AT Command: AT+CDP** 788 788 789 789 This command can be used to search the saved history, recording up to 32 groups of data, each group of historical data contains a maximum of 100 bytes. ... ... @@ -792,28 +792,11 @@ 792 792 [[image:image-20240316151014-2.png||height="632" width="825"]] 793 793 794 794 795 -== 2.16 Uplink log query == 796 796 797 797 798 -* (% style="color:blue" %)**AT Command: AT+GETLOG** 799 799 800 -This command can be used to query upstream logs of data packets. 801 801 802 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-NB-NA_NB-IoT_Analog_Sensor_User_Manual/WebHome/image-20240407191922-2.png?width=903&height=631&rev=1.1||alt="image-20240407191922-2.png"]] 803 803 804 - 805 -== 2.17 Scheduled domain name resolution == 806 - 807 - 808 -This command is used to set up scheduled domain name resolution. 809 - 810 -(% style="color:blue" %)**AT command:** 811 - 812 -* (% style="color:#037691" %)**AT+DNSTIMER=XX **(%%)~/~/ Unit: hour 813 - 814 -After setting this command, domain name resolution will be performed regularly. 815 - 816 - 817 817 = 3. Configure DS03A-NB = 818 818 819 819 == 3.1 Configure Methods == ... ... @@ -877,6 +877,11 @@ 877 877 AT+SERVADDR : Server Address 878 878 879 879 865 +(% style="color:blue" %)**UDP Management** 866 + 867 +AT+CFM : Upload confirmation mode (only valid for UDP) 868 + 869 + 880 880 (% style="color:blue" %)**MQTT Management** 881 881 882 882 AT+CLIENT : Get or Set MQTT client ... ... @@ -929,7 +929,7 @@ 929 929 930 930 = 6. FAQ = 931 931 932 -== 6.1 How can I access t heBC660K-GL AT Commands? ==922 +== 6.1 How can I access t BC660K-GL AT Commands? == 933 933 934 934 935 935 User can access to BC660K-GL directly and send AT Commands. ... ... @@ -937,13 +937,6 @@ 937 937 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 938 938 939 939 940 -== 6.2 How to configure the certificate? == 941 - 942 - 943 -User can can refer to this [[description>>url:http://wiki.dragino.com/xwiki/bin/view/How%20to%20configure%20the%20certificate%3F/]] to configure the certificate. 944 - 945 - 946 - 947 947 = 7. Order Info = 948 948 949 949