Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
From version 139.1
edited by Mengting Qiu
on 2024/05/09 11:47
on 2024/05/09 11:47
Change comment:
There is no comment for this version
To version 140.1
edited by Mengting Qiu
on 2024/05/20 15:02
on 2024/05/20 15:02
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -439,8 +439,9 @@ 439 439 440 440 == 2.4 Multi-Samplings and One uplink == 441 441 442 -(% style="color:red" %)Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]] 443 443 443 +(% style="color:red" %)**Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]].** 444 + 444 444 To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 445 445 446 446 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) ... ... @@ -801,8 +801,18 @@ 801 801 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-NB-NA_NB-IoT_Analog_Sensor_User_Manual/WebHome/image-20240407191922-2.png?width=903&height=631&rev=1.1||alt="image-20240407191922-2.png"]] 802 802 803 803 805 +== 2.17 Scheduled domain name resolution == 804 804 805 805 808 +This command is used to set up scheduled domain name resolution. 809 + 810 +(% style="color:blue" %)**AT command:** 811 + 812 +* (% style="color:#037691" %)**AT+DNSTIMER=XX **(%%)~/~/ Unit: hour 813 + 814 +After setting this command, domain name resolution will be performed regularly. 815 + 816 + 806 806 = 3. Configure DS03A-NB = 807 807 808 808 == 3.1 Configure Methods == ... ... @@ -918,7 +918,7 @@ 918 918 919 919 = 6. FAQ = 920 920 921 -== 6.1 How can I access t BC660K-GL AT Commands? == 932 +== 6.1 How can I access the BC660K-GL AT Commands? == 922 922 923 923 924 924 User can access to BC660K-GL directly and send AT Commands. ... ... @@ -926,6 +926,13 @@ 926 926 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 927 927 928 928 940 +== 6.2 How to configure the certificate? == 941 + 942 + 943 +User can can refer to this [[description>>url:http://wiki.dragino.com/xwiki/bin/view/How%20to%20configure%20the%20certificate%3F/]] to configure the certificate. 944 + 945 + 946 + 929 929 = 7. Order Info = 930 930 931 931