Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 139.1
edited by Mengting Qiu
on 2024/05/09 11:47
Change comment: There is no comment for this version
To version 140.1
edited by Mengting Qiu
on 2024/05/20 15:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -439,8 +439,9 @@
439 439  
440 440  == 2.4 Multi-Samplings and One uplink ==
441 441  
442 -(% style="color:red" %)Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]]
443 443  
443 +(% style="color:red" %)**Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]].**
444 +
444 444  To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
445 445  
446 446  * (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
... ... @@ -801,8 +801,18 @@
801 801  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-NB-NA_NB-IoT_Analog_Sensor_User_Manual/WebHome/image-20240407191922-2.png?width=903&height=631&rev=1.1||alt="image-20240407191922-2.png"]]
802 802  
803 803  
805 +== 2.17 Scheduled domain name resolution ==
804 804  
805 805  
808 +This command is used to set up scheduled domain name resolution.
809 +
810 +(% style="color:blue" %)**AT command:**
811 +
812 +* (% style="color:#037691" %)**AT+DNSTIMER=XX   **(%%)~/~/ Unit: hour
813 +
814 +After setting this command, domain name resolution will be performed regularly.
815 +
816 +
806 806  = 3. Configure DS03A-NB =
807 807  
808 808  == 3.1 Configure Methods ==
... ... @@ -918,7 +918,7 @@
918 918  
919 919  = 6. FAQ =
920 920  
921 -== 6.1 How can I access t BC660K-GL AT Commands? ==
932 +== 6.1 How can I access the BC660K-GL AT Commands? ==
922 922  
923 923  
924 924  User can access to BC660K-GL directly and send AT Commands.
... ... @@ -926,6 +926,13 @@
926 926  [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
927 927  
928 928  
940 +== 6.2 How to configure the certificate? ==
941 +
942 +
943 +User can can refer to this [[description>>url:http://wiki.dragino.com/xwiki/bin/view/How%20to%20configure%20the%20certificate%3F/]] to configure the certificate.
944 +
945 +
946 +
929 929  = 7. Order Info =
930 930  
931 931