Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
From version 138.2
edited by Mengting Qiu
on 2024/05/09 11:46
on 2024/05/09 11:46
Change comment:
There is no comment for this version
To version 143.1
edited by Mengting Qiu
on 2024/06/11 15:09
on 2024/06/11 15:09
Change comment:
Uploaded new attachment "image-20240611150928-3.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -440,6 +440,8 @@ 440 440 == 2.4 Multi-Samplings and One uplink == 441 441 442 442 443 +(% style="color:red" %)**Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]].** 444 + 443 443 To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 444 444 445 445 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) ... ... @@ -800,8 +800,18 @@ 800 800 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-NB-NA_NB-IoT_Analog_Sensor_User_Manual/WebHome/image-20240407191922-2.png?width=903&height=631&rev=1.1||alt="image-20240407191922-2.png"]] 801 801 802 802 805 +== 2.17 Scheduled domain name resolution == 803 803 804 804 808 +This command is used to set up scheduled domain name resolution. 809 + 810 +(% style="color:blue" %)**AT command:** 811 + 812 +* (% style="color:#037691" %)**AT+DNSTIMER=XX **(%%)~/~/ Unit: hour 813 + 814 +After setting this command, domain name resolution will be performed regularly. 815 + 816 + 805 805 = 3. Configure DS03A-NB = 806 806 807 807 == 3.1 Configure Methods == ... ... @@ -917,7 +917,7 @@ 917 917 918 918 = 6. FAQ = 919 919 920 -== 6.1 How can I access t BC660K-GL AT Commands? == 932 +== 6.1 How can I access the BC660K-GL AT Commands? == 921 921 922 922 923 923 User can access to BC660K-GL directly and send AT Commands. ... ... @@ -925,6 +925,13 @@ 925 925 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 926 926 927 927 940 +== 6.2 How to configure the certificate? == 941 + 942 + 943 +User can can refer to this [[description>>url:http://wiki.dragino.com/xwiki/bin/view/How%20to%20configure%20the%20certificate%3F/]] to configure the certificate. 944 + 945 + 946 + 928 928 = 7. Order Info = 929 929 930 930
- image-20240611150437-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.6 KB - Content
- image-20240611150520-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.8 KB - Content
- image-20240611150928-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.8 KB - Content