Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
From version 137.1
edited by Mengting Qiu
on 2024/03/16 15:10
on 2024/03/16 15:10
Change comment:
There is no comment for this version
To version 139.1
edited by Mengting Qiu
on 2024/05/09 11:47
on 2024/05/09 11:47
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -439,6 +439,7 @@ 439 439 440 440 == 2.4 Multi-Samplings and One uplink == 441 441 442 +(% style="color:red" %)Notice: The AT+NOUD feature is upgraded to Clock Logging, please refer [[Clock Logging Feature>>||anchor="H2.14Clocklogging28Sincefirmwareversionv1.2.129"]] 442 442 443 443 To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 444 444 ... ... @@ -747,11 +747,9 @@ 747 747 0xA6 02 00 00 32 ==> AT+SETCNT=2,50 748 748 749 749 750 - 751 - 752 - 753 753 == 2.14 Clock logging (Since firmware version v1.2.1) == 754 754 753 + 755 755 Sometimes when we deploy lots of end nodes in field. We want all sensors sample data at the same time, and upload these data together for analyze. In such case, we can use clock loging feature. 756 756 757 757 We can use this command to set the start time of data recording and the time interval to meet the requirements of the specific collection time of data. ... ... @@ -760,7 +760,7 @@ 760 760 761 761 (% style="color:blue" %)**a:**(%%)** 0:** Disable Clock logging. ** 1: **Enable Clock Logging 762 762 763 -(% style="color:blue" %)**b:**(%%)** **Specify First sampling start second: range **(0 ~~ 3599, 65535) ** ~/~/**Note: **If parameter b is set to 65535, the log period starts after the node accesses the network and sends packets. 762 +(% style="color:blue" %)**b:**(%%)** **Specify First sampling start second: range **(0 ~~ 3599, 65535) ** ~/~/ (% style="color:red" %)**Note:**(%%)** **If parameter b is set to 65535, the log period starts after the node accesses the network and sends packets. 764 764 765 765 (% style="color:blue" %)**c:**(%%)** **Specify the sampling interval: range **(0 ~~ 255 minutes)** 766 766 ... ... @@ -781,11 +781,9 @@ 781 781 (% style="color:red" %)**Note: Users need to synchronize the server time before configuring this command. If the server time is not synchronized before this command is configured, the command takes effect only after the node is reset.** 782 782 783 783 783 +== 2.15 Example Query saved historical records == 784 784 785 785 786 - 787 -== 2.8 Example Query saved historical records == 788 - 789 789 * (% style="color:blue" %)**AT Command: AT+CDP** 790 790 791 791 This command can be used to search the saved history, recording up to 32 groups of data, each group of historical data contains a maximum of 100 bytes. ... ... @@ -794,11 +794,18 @@ 794 794 [[image:image-20240316151014-2.png||height="632" width="825"]] 795 795 796 796 794 +== 2.16 Uplink log query == 797 797 798 798 797 +* (% style="color:blue" %)**AT Command: AT+GETLOG** 799 799 799 +This command can be used to query upstream logs of data packets. 800 800 801 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-NB-NA_NB-IoT_Analog_Sensor_User_Manual/WebHome/image-20240407191922-2.png?width=903&height=631&rev=1.1||alt="image-20240407191922-2.png"]] 801 801 803 + 804 + 805 + 802 802 = 3. Configure DS03A-NB = 803 803 804 804 == 3.1 Configure Methods == ... ... @@ -862,11 +862,6 @@ 862 862 AT+SERVADDR : Server Address 863 863 864 864 865 -(% style="color:blue" %)**UDP Management** 866 - 867 -AT+CFM : Upload confirmation mode (only valid for UDP) 868 - 869 - 870 870 (% style="color:blue" %)**MQTT Management** 871 871 872 872 AT+CLIENT : Get or Set MQTT client