Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 107.3
edited by Xiaoling
on 2023/10/11 09:40
Change comment: There is no comment for this version
To version 107.4
edited by Xiaoling
on 2023/10/11 10:04
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,7 +22,7 @@
22 22  
23 23  The DS03A-NB will send periodically data every 2 hours as well as for each door open/close action. It also counts the door open times and calculates the last door open duration. Users can also disable the uplink for each open/close event, instead, DS03A-NB can count each open event and uplink periodically.
24 24  
25 -DS03A-LB supports (% style="color:blue" %)**Datalog Feature,** (%%)it can save the data when there is no NB-IoT network and uplink when network recover.
25 +DS03A-LB supports (% style="color:blue" %)**Datalog Feature,** (%%)it can save the data when there is no NB-IoT network and uplink when network recover.
26 26  
27 27  DS03A-LB has the (% style="color:blue" %)**Open Alarm Feature**,(%%) user can set this feature so the device will send an alarm if the door has been open for a certain time.
28 28  
... ... @@ -45,7 +45,10 @@
45 45  * NB-IoT Bands: B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 @H-FDD
46 46  * Ultra-low power consumption
47 47  * Upload water flow volume
48 -* Monitor water waste
48 +* Door Open/Close detect
49 +* Door open/close statistics
50 +* Datalog Feature
51 +* Open Alarm Feature
49 49  * Multiply Sampling and one uplink
50 50  * Support Bluetooth v5.1 remote configure and update firmware
51 51  * Uplink on periodically
... ... @@ -53,7 +53,6 @@
53 53  * 8500mAh Battery for long term use
54 54  * Nano SIM card slot for NB-IoT SIM
55 55  
56 -
57 57  == 1.3 Specification ==
58 58  
59 59  
... ... @@ -103,28 +103,11 @@
103 103  (% style="display:none" %) (%%)
104 104  
105 105  
106 -== 1.4 Flow Sensor Spec ==
108 +== 1.4 Applications ==
107 107  
108 108  
109 -(((
110 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
111 -|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Model**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Probe**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Diameter**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Range**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Max Pressure**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Measure**
112 -|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L
113 -|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L
114 -|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L
115 -)))
111 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654741400370-813.png?rev=1.1||alt="1654741400370-813.png"]]
116 116  
117 -
118 -
119 -== 1.5 Applications ==
120 -
121 -
122 -* Flow Sensor application
123 -* Water Control
124 -* Toilet Flow Sensor
125 -* Monitor Waste water
126 -
127 -
128 128  == 1.6 Sleep mode and working mode ==
129 129  
130 130  
... ... @@ -152,7 +152,6 @@
152 152  )))
153 153  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
154 154  
155 -
156 156  == 1.8 BLE connection ==
157 157  
158 158  
... ... @@ -314,7 +314,6 @@
314 314  
315 315  * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Water Flow, Sampling time.
316 316  
317 -
318 318  === 2.2.2 HEX format Payload(Type~=0) ===
319 319  
320 320  
... ... @@ -758,7 +758,6 @@
758 758  
759 759  * (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
760 760  
761 -
762 762  == 2.7 Alarm for continuously water flow ==
763 763  
764 764  
... ... @@ -851,7 +851,6 @@
851 851  
852 852  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
853 853  
854 -
855 855  == 2.9 Set count number ==
856 856  
857 857  
... ... @@ -870,7 +870,6 @@
870 870  
871 871  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
872 872  
873 -
874 874  == 2.10 Set Transmit Interval Time ==
875 875  
876 876  
... ... @@ -927,7 +927,6 @@
927 927  
928 928  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
929 929  
930 -
931 931  == 3.2 AT Commands Set ==
932 932  
933 933  
... ... @@ -1033,7 +1033,6 @@
1033 1033  
1034 1034  * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1035 1035  
1036 -
1037 1037  = 6. FAQ =
1038 1038  
1039 1039  == 6.1 How can I access t BC660K-GL AT Commands? ==
... ... @@ -1107,7 +1107,6 @@
1107 1107  
1108 1108  * Weight / pcs : 180g
1109 1109  
1110 -
1111 1111  = 9. Support =
1112 1112  
1113 1113