Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -376,7 +376,7 @@ 376 376 377 377 == 2.3 Uplink Payload == 378 378 379 -=== 2.3. 2Sensor Configuration, FPORT~=4 ===379 +=== 2.3.1 Sensor Configuration, FPORT~=4 === 380 380 381 381 382 382 DS03A-NB will only send this command after getting the downlink command **(0x26 02)** from the server. ... ... @@ -433,7 +433,7 @@ 433 433 When the state of the door sensor has not been changed after the timeout alarm, the device will send a uplink every alarm interval. It will stop the alarm until the state of the door sensor is changed after the timeout alarm. 434 434 435 435 436 -=== 2.3. 3Real-Time Open/Close Status, Uplink FPORT~=2 ===436 +=== 2.3.2 Real-Time Open/Close Status, Uplink FPORT~=2 === 437 437 438 438 439 439 DS03A-NB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And DS03A-NB will send uplinks when: ... ... @@ -609,7 +609,7 @@ 609 609 [[image:image-20230701094042-1.png||height="154" width="763"]] 610 610 611 611 612 -=== 2.3. 4Historical Door Open/Close Event, FPORT~=3 ===612 +=== 2.3.3 Historical Door Open/Close Event, FPORT~=3 === 613 613 614 614 615 615 DS03A-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. ... ... @@ -786,7 +786,7 @@ 786 786 ))) 787 787 788 788 789 -== =3.3.3=789 +== 2.8 Enable / Disable Alarm == 790 790 791 791 792 792 Feature: Enable/Disable Alarm for open/close event. Default value 0. ... ... @@ -794,7 +794,7 @@ 794 794 (% style="color:blue" %)**AT Command: ** 795 795 796 796 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 797 -|(% style="background-color:# d9e2f3;#0070c0; width:153px" %)**Command Example**|(% style="background-color:#d9e2f3;#0070c0; width:276px" %)**Function**|(% style="background-color:#d9e2f3;#0070c0; width:86px" %)**Response**797 +|(% style="background-color:#4F81BD;color:white; width:153px" %)**Command Example**|(% style="background-color:#4F81BD;color:white; width:276px" %)**Function**|(% style="background-color:#4F81BD;color:white; width:86px" %)**Response** 798 798 |(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 799 799 |(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 800 800 ... ... @@ -805,7 +805,7 @@ 805 805 0xA7 00 ~/~/ Same As AT+DISALARM=0 806 806 807 807 808 -== =3.3.4Alarm Base on Timeout ===808 +== 2.9 Alarm Base on Timeout == 809 809 810 810 811 811 DS03A-NB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: ... ... @@ -889,7 +889,7 @@ 889 889 If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 890 890 891 891 892 -== =3.3.5TTRIG1 & TTRIG2 timeout status alarm ===892 +== 2.10 TTRIG1 & TTRIG2 timeout status alarm == 893 893 894 894 895 895 It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. ... ... @@ -897,7 +897,7 @@ 897 897 (% style="color:blue" %)**AT Command:** 898 898 899 899 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 900 -|=(% style="width: 155px;background-color:# D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 279px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 76px;background-color:#D9E2F3;color:#0070C0" %)**Response**900 +|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 279px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 76px;background-color:#4F81BD;color:white" %)**Response** 901 901 |(% style="width:155px" %)((( 902 902 AT+TTRALARM=0 903 903 )))|(% style="width:279px" %)((( ... ... @@ -918,7 +918,7 @@ 918 918 Example: 0C aa => AT+TTRALARM= aa 919 919 920 920 921 -== =3.3.6Count Mod ===921 +== 2.11 Count Mod == 922 922 923 923 924 924 Feature: Manually set the count mode. ... ... @@ -947,7 +947,7 @@ 947 947 Example: 0B aa => AT+COUNTMOD = second byte 948 948 949 949 950 -== =3.3.7Number of channel of door sensors ===950 +== 2.12 Number of channel of door sensors == 951 951 952 952 953 953 Feature: Set the number of door sensor channels. ... ... @@ -976,7 +976,7 @@ 976 976 Example: 0D aa => AT+TTRCHANNEL = second byte 977 977 978 978 979 -== =3.3.8Set Time Sync Mode ===979 +== 2.13 Set Time Sync Mode == 980 980 981 981 982 982 Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command. ... ... @@ -1014,7 +1014,7 @@ 1014 1014 0x28 00 ~/~/ Same As AT+SYNCMOD=0 1015 1015 1016 1016 1017 -== =3.3.9Clear the open door times and the duration of the last open door ===1017 +== 2.14 Clear the open door times and the duration of the last open door == 1018 1018 1019 1019 1020 1020 (% style="color:blue" %)**AT Command:** ... ... @@ -1030,7 +1030,7 @@ 1030 1030 The sensor will clear the open door times and the duration of the last open door. 1031 1031 1032 1032 1033 -== =3.3.10Set the count value of the number of open door ===1033 +== 2.15 Set the count value of the number of open door == 1034 1034 1035 1035 1036 1036 (% style="color:blue" %)**AT Command:**