... ... @@ -376,7 +376,7 @@
376 376  
377 377  == 2.3  ​Uplink Payload ==
378 378  
379 -=== 2.3.2  Sensor Configuration, FPORT~=4 ===
379 +=== 2.3.1  Sensor Configuration, FPORT~=4 ===
380 380  
381 381  
382 382  DS03A-NB will only send this command after getting the downlink command **(0x26 02)** from the server.
... ... @@ -433,7 +433,7 @@
433 433  When the state of the door sensor has not been changed after the timeout alarm, the device will send a uplink every alarm interval. It will stop the alarm until the state of the door sensor is changed after the timeout alarm.
434 434  
435 435  
436 -=== 2.3.3  Real-Time Open/Close Status, Uplink FPORT~=2 ===
436 +=== 2.3.2  Real-Time Open/Close Status, Uplink FPORT~=2 ===
437 437  
438 438  
439 439  DS03A-NB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And DS03A-NB will send uplinks when:
... ... @@ -609,7 +609,7 @@
609 609  [[image:image-20230701094042-1.png||height="154" width="763"]]
610 610  
611 611  
612 -=== 2.3.4  Historical Door Open/Close Event, FPORT~=3 ===
612 +=== 2.3.3  Historical Door Open/Close Event, FPORT~=3 ===
613 613  
614 614  
615 615  DS03A-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
... ... @@ -786,7 +786,7 @@
786 786  )))
787 787  
788 788  
789 -=== 3.3.3  Enable / Disable Alarm ===
789 +== 2.8 Enable / Disable Alarm ==
790 790  
791 791  
792 792  Feature: Enable/Disable Alarm for open/close event. Default value 0.
... ... @@ -794,7 +794,7 @@
794 794  (% style="color:blue" %)**AT Command: **
795 795  
796 796  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
797 -|(% style="background-color:#d9e2f3; color:#0070c0; width:153px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:276px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:86px" %)**Response**
797 +|(% style="background-color:#4F81BD;color:white; width:153px" %)**Command Example**|(% style="background-color:#4F81BD;color:white; width:276px" %)**Function**|(% style="background-color:#4F81BD;color:white; width:86px" %)**Response**
798 798  |(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK
799 799  |(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK
800 800  
... ... @@ -805,7 +805,7 @@
805 805  0xA7 00  ~/~/ Same As AT+DISALARM=0
806 806  
807 807  
808 -=== 3.3.4  Alarm Base on Timeout ===
808 +== 2.9  Alarm Base on Timeout ==
809 809  
810 810  
811 811  DS03A-NB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
... ... @@ -889,7 +889,7 @@
889 889  If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30  **or**  0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0.
890 890  
891 891  
892 -=== 3.3.5  TTRIG1 & TTRIG2 timeout status alarm ===
892 +== 2.10 TTRIG1 & TTRIG2 timeout status alarm ==
893 893  
894 894  
895 895  It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
... ... @@ -897,7 +897,7 @@
897 897  (% style="color:blue" %)**AT Command:**
898 898  
899 899  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
900 -|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 279px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 76px;background-color:#D9E2F3;color:#0070C0" %)**Response**
900 +|=(% style="width: 155px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 279px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 76px;background-color:#4F81BD;color:white" %)**Response**
901 901  |(% style="width:155px" %)(((
902 902  AT+TTRALARM=0
903 903  )))|(% style="width:279px" %)(((
... ... @@ -918,7 +918,7 @@
918 918  Example:  0C aa  => AT+TTRALARM= aa
919 919  
920 920  
921 -=== 3.3.6  Count Mod ===
921 +== 2.11 Count Mod ==
922 922  
923 923  
924 924  Feature: Manually set the count mode.
... ... @@ -947,7 +947,7 @@
947 947  Example:  0B aa  => AT+COUNTMOD = second byte
948 948  
949 949  
950 -=== 3.3.7  Number of channel of door sensors ===
950 +== 2.12  Number of channel of door sensors ==
951 951  
952 952  
953 953  Feature: Set the number of door sensor channels.
... ... @@ -976,7 +976,7 @@
976 976  Example:  0D aa => AT+TTRCHANNEL = second byte
977 977  
978 978  
979 -=== 3.3.8  Set Time Sync Mode ===
979 +== 2.13 Set Time Sync Mode ==
980 980  
981 981  
982 982  Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command.
... ... @@ -1014,7 +1014,7 @@
1014 1014  0x28 00  ~/~/ Same As AT+SYNCMOD=0
1015 1015  
1016 1016  
1017 -=== 3.3.9  Clear the open door times and the duration of the last open door ===
1017 +== 2.14  Clear the open door times and the duration of the last open door ==
1018 1018  
1019 1019  
1020 1020  (% style="color:blue" %)**AT Command:**
... ... @@ -1030,7 +1030,7 @@
1030 1030  The sensor will clear the open door times and the duration of the last open door.
1031 1031  
1032 1032  
1033 -=== 3.3.10  Set the count value of the number of open door ===
1033 +== 2.15  Set the count value of the number of open door ==
1034 1034  
1035 1035  
1036 1036  (% style="color:blue" %)**AT Command:**