Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,19 +22,19 @@ 22 22 23 23 The DS03A-NB will send periodically data every 2 hours as well as for each door open/close action. It also counts the door open times and calculates the last door open duration. Users can also disable the uplink for each open/close event, instead, DS03A-NB can count each open event and uplink periodically. 24 24 25 -DS03A- NB supports (% style="color:blue" %)**Datalog Feature,** (%%)it can save the data when there is no NB-IoT network and uplink when network recover.25 +DS03A-LB supports (% style="color:blue" %)**Datalog Feature,** (%%)it can save the data when there is no NB-IoT network and uplink when network recover. 26 26 27 -DS03A- NB has the (% style="color:blue" %)**Open Alarm Feature**,(%%) user can set this feature so the device will send an alarm if the door has been open for a certain time.27 +DS03A-LB has the (% style="color:blue" %)**Open Alarm Feature**,(%%) user can set this feature so the device will send an alarm if the door has been open for a certain time. 28 28 29 -DS03A- NB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures29 +DS03A-LB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures 30 30 31 - DS03A-NB supports different uplink methods including (% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%) for different application requirement, and support uplinks to various IoT Servers.31 +SW3L-NB supports different uplink methods including (% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%) for different application requirement, and support uplinks to various IoT Servers. 32 32 33 - DS03A-NB (% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%) which make user easy to use.33 +SW3L-NB (% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%) which make user easy to use. 34 34 35 - DS03A-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long-term use up to several years.35 +SW3L-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long-term use up to several years. 36 36 37 - DS03A-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration.37 +SW3L-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration. 38 38 39 39 [[image:image-20231011093807-6.png||height="278" width="879"]] 40 40 ... ... @@ -141,7 +141,7 @@ 141 141 == 1.7 BLE connection == 142 142 143 143 144 - DS03A-NB support BLE remote configure and firmware update.144 +SW3L-NB support BLE remote configure and firmware update. 145 145 146 146 147 147 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -211,18 +211,18 @@ 211 211 == 2.1 Send data to IoT server via NB-IoT network == 212 212 213 213 214 -The DS03A-NB is equipped with a NB-IoT module, the pre-loaded firmware inDS03A-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined byDS03A-NB.214 +The SW3L-NB is equipped with a NB-IoT module, the pre-loaded firmware in SW3L-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by SW3L-NB. 215 215 216 216 217 217 Below shows the network structure: 218 218 219 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/ DS03A-NB_NB-IoT_Door_Sensor_User_Manual/WebHome/image-20231011093807-6.png?width=879&height=278&rev=1.1||alt="image-20231011093807-6.png"]]219 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-NB_NB-IoT_Flow_Sensor_User_Manual/WebHome/image-20231010091546-2.png?width=909&height=348&rev=1.1||alt="image-20231010091546-2.png"]] 220 220 221 221 222 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DS03A-NB.222 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of SW3L-NB. 223 223 224 224 225 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DS03A-NB send data to IoT server.225 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set SW3L-NB send data to IoT server. 226 226 227 227 * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]]. 228 228 ... ... @@ -252,13 +252,13 @@ 252 252 [[image:image-20230819113244-11.png||height="141" width="367"]] 253 253 )))|(% style="width:170px" %) 254 254 255 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DS03A-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].255 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate SW3L-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]]. 256 256 257 257 258 258 == 2.2 Payload Types == 259 259 260 260 261 -To meet different server requirement, DS03A-NB supports different payload type.261 +To meet different server requirement, SW3L-NB supports different payload type. 262 262 263 263 **Includes:** 264 264 ... ... @@ -284,7 +284,7 @@ 284 284 285 285 This is the General Json Format. As below: 286 286 287 -(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":" DS03A-NB","flow":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**287 +(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"SW3L-NB","flow":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}** 288 288 289 289 290 290 [[image:image-20230920175015-3.png||height="613" width="890"]] ... ... @@ -315,7 +315,7 @@ 315 315 316 316 These bytes include the hardware and software version. 317 317 318 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x1 2forDS03A-NB318 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x11 for SW3L-NB 319 319 320 320 (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 1.0.0 321 321 ... ... @@ -354,7 +354,7 @@ 354 354 355 355 Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard. 356 356 357 -(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": " DS03A","flow": 502,"battery": 3.57,"signal": 23}**357 +(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "SW3L","flow": 502,"battery": 3.57,"signal": 23}** 358 358 359 359 [[image:image-20230922094043-2.png||height="558" width="851"]] 360 360 ... ... @@ -376,328 +376,326 @@ 376 376 377 377 == 2.3 Uplink Payload == 378 378 379 -=== 2.3. 2Sensor Configuration, FPORT~=4 ===379 +=== 2.3.1 Sensor Configuration, FPORT~=4 === 380 380 381 381 382 - DS03A-NB will only send this command after getting the downlink command **(0x26 02)** from the server.382 +SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server. 383 383 384 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 385 -|(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4** 386 -|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:50px" %)**1**|(% style="width:100px" %)**1**|(% style="width:90px" %)**2**|(% style="width:100px" %)**1**|(% style="width:100px" %)**2**|(% style="width:98px" %)**1** 387 -|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)((( 388 -Keep status1 389 -)))|(% style="width:99px" %)((( 390 -Keep time1(unit: sec) 391 -)))|(% style="width:87px" %)Keep status2|(% style="width:97px" %)((( 392 -Keep time2(unit: sec) 393 -)))|(% style="width:98px" %)((( 394 -Alarm interval(unit: min) 395 -))) 384 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 385 +|(% style="background-color:#4f81bd; color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:105px" %)**3**|(% style="background-color:#4f81bd; color:white; width:60px" %)**1**|(% style="background-color:#4f81bd; color:white; width:96px" %)**1**|(% style="background-color:#4f81bd; color:white; width:105px" %)**2**|(% style="background-color:#4f81bd; color:white; width:74px" %)**1** 386 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 396 396 397 397 Example parse in TTNv3 398 398 399 -[[image:image-202306 30155527-3.png||height="146" width="902"]]390 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230614172555-4.png?width=853&height=151&rev=1.1||alt="image-20230614172555-4.png"]] 400 400 401 401 402 -* ((( 403 -(% style="color:blue" %)**TDC: (default: 0x001C20)** 404 -))) 393 +* (% style="color:blue" %)**TDC: (default: 0x0004B0)** 405 405 406 -Uplink interval for the Open/CloseEvent, default value is 0x001C20 which is7200 seconds = 2hours.395 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 407 407 408 408 409 -* ((( 410 -(% style="color:blue" %)**Disalarm: (default: 0)** 411 -))) 398 +* (% style="color:blue" %)**STOP Duration & Alarm Timer** 412 412 413 - **If Disalarm = 1**, DS03A-NB willonlysenduplink atveryTDC periodically. This is normallyuseforpulsemeterapplication, inthis application, thereare many open/close event,and platformonlycare aboutthetotal numberofpulse.400 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]] 414 414 415 - **If Disalarm = 0**, DS03A-NB will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time. 416 416 403 +=== 2.3.2 Water Flow Value, Uplink FPORT~=2 === 417 417 418 -(% style="color:red" %)** Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. ** 419 419 406 +((( 407 +SW3L-NB will send this uplink **after** Device Status once join the NB-IoT network successfully. And SW3L-NB will: 408 +))) 420 420 421 - *(((422 - (% style="color:blue"%)**KeepStatus1&KeepTime1&KeepStatus2 & KeepTime2**410 +((( 411 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H2.10SetTransmitIntervalTime"]]. 423 423 ))) 424 424 425 -Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 426 - 427 - 428 - 429 -* ((( 430 -(% style="color:blue" %)**Alarm interval(default: 0)** 414 +((( 415 +Uplink Payload totals 11 bytes. 431 431 ))) 432 432 433 -When the state of the door sensor has not been changed after the timeout alarm, the device will send a uplink every alarm interval. It will stop the alarm until the state of the door sensor is changed after the timeout alarm. 418 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 419 +|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value, FPORT=2** 420 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 421 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 422 +Total pulse Or Last Pulse 423 +)))|(% style="width:78px" %)((( 424 +MOD & PA4_status & PB15_status 425 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)Unix TimeStamp 434 434 427 +**Calculate Flag & Alarm:** 435 435 436 -=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 429 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 430 +|(% style="background-color:#4f81bd; color:white; width:70px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:70px" %)**[bit7:bit6]**|(% style="background-color:#4f81bd; color:white; width:90px" %)**[bit5:bit2]**|(% style="background-color:#4f81bd; color:white; width:140px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:130px" %)**bit0** 431 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes 437 437 433 +**MOD & PA4_status & PB15_status:** 438 438 439 -DS03A-NB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And DS03A-NB will send uplinks when: 435 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %) 436 +|(% style="background-color:#4f81bd; color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:60px" %)**[bit5:bit0]** 437 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 440 440 441 -* Every 2 hours, this interval [[can be changed>>||anchor="H3.3.1A0SetTransmitIntervalTime"]]. 442 -* There is an Open/Close event. (This info can be disabled by AT+DISALARM=1) 439 +(% style="color:#037691" %)** **[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230626093242-1.png?width=892&height=276&rev=1.1||alt="image-20230626093242-1.png"]] 443 443 444 -**1) When (% style="color:blue" %)AT+TTRCHANNEL=1(%%), Uplink Payload totals (% style="color:blue" %)11 bytes. (Default mode)(%%)** 445 445 446 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 447 -|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0;width:515px" %)**Real-Time Open/Close Status, FPORT=2** 448 -|(% style="width:94px" %)**Size(bytes)**|(% style="width:97px" %)**1**|(% style="width:95px" %)**3**|(% style="width:119px" %)**3**|(% style="width:107px" %)**4** 449 -|(% style="width:95px" %)**Value**|(% style="width:97px" %)((( 450 -Status & [[Alarm>>||anchor="H3.3.4A0TTRIG126TTRIG2timeoutstatusalarm"]] 451 -)))|(% style="width:95px" %)Total open door events|(% style="width:119px" %)((( 452 -The last door open duration (unit: sec) 453 -)))|(% style="width:108px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 442 +* ((( 443 +(% style="color:blue" %)**Calculate Flag** 444 +))) 454 454 455 -**Status & Alarm:** 446 +((( 447 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 448 +))) 456 456 457 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 458 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**bit0** 459 -|(% style="width:76px" %)**Value**|(% style="width:96px" %)Reserve|(% style="width:110px" %)((( 460 -Count mod 461 -)))|(% style="width:106px" %)TDC flag 0:No;1:Yes|(% style="width:148px" %)((( 462 -Alarm 0: No Alarm; 1: Alarm 463 -)))|(% style="width:131px" %)((( 464 -Status 0: Close; 1: Open 450 +((( 451 +**Example: in the default payload:** 465 465 ))) 466 466 467 -[[image:image-20230630155451-2.png||height="246" width="928"]] 468 - 469 - 470 470 * ((( 471 - (% style="color:blue"%)**Countmod:Default=0**455 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 472 472 ))) 473 - 474 -0: Uplink total open door times since factory 475 - 476 -1: Uplink total open door times since last FPORT=2 uplink. 477 - 478 - 479 -* (% style="color:blue" %)**TDC flag** 480 - 481 -When the flag is 1, it means sending packets at normal time intervals. 482 - 483 -Otherwise, it is a packet sent at non-TDC time. 484 - 485 - 486 486 * ((( 487 - (% style="color:#0000ff"%)**Alarm**458 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 488 488 ))) 489 - 490 -See [[Alarm Base on Timeout>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 491 - 492 - 493 493 * ((( 494 - (% style="color:blue"%)**Status**461 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 495 495 ))) 496 496 497 -This bit is 1 when the door sensor is open and 0 when it is close. 498 - 499 - 500 -* ((( 501 -(% style="color:blue" %)**Total open door events** 464 +((( 465 +Default value: 0. 502 502 ))) 503 503 504 -Total pulse/counting base on open door. 468 +((( 469 +Range (4 bits): (b)0000 ~~ (b) 1111 505 505 506 - Range(3Bytes):0x000000~~0xFFFFFF.Max:16777215471 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 507 507 473 +1) User can set the Calculate Flag of this sensor to 3. 508 508 509 -* ((( 510 -(% style="color:blue" %)**The last door open duration** 475 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 511 511 ))) 512 512 513 -Door sensor last open duration. 478 +((( 479 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H2.8Setthecalculateflag"]] 514 514 515 -Unit: sec. 481 +((( 482 + 483 +))) 484 +))) 516 516 517 -[[image:image-20230701094042-1.png||height="154" width="763"]] 518 518 487 +* ((( 488 +(% style="color:blue" %)**Alarm** 489 +))) 519 519 520 -**2) When (% style="color:blue" %)AT+TTRCHANNEL=2(%%), Uplink Payload totals (% style="color:blue" %)18 bytes(%%)**(% style="color:blue" %). 491 +((( 492 +See [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]] 493 +))) 521 521 522 - (When the maximum DRof some frequenciesis 11bytes,itwill causetheerver toceive empty packets)495 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 523 523 524 -(% style="color:red" %)**Note:When using the AT+TTRCHANNEL=2 command, the Datalog function cannot be used.** 525 525 526 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 527 -|=(% colspan="8" style="background-color:#D9E2F3;color:#0070C0; width: 515px;" %)**Real-Time Open/Close Status, FPORT=2** 528 -|(% style="width:50px" %)**Size(bytes)**|(% style="width:97px" %)**1**|(% style="width:95px" %)**3**|(% style="width:125px" %)**3**|(% style="width:100px" %)**4**|(% style="width:86px" %)**1**|(% style="width:96px" %)**3**|(% style="width:126px" %)**3** 529 -|(% style="width:95px" %)**Value**|(% style="width:97px" %)((( 530 -Status1 & Alarm1 531 -)))|(% style="width:95px" %)Total open door events1|(% style="width:125px" %)((( 532 -The last door open duration1 (unit: sec) 533 -)))|(% style="width:100px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]|(% style="width:86px" %)((( 534 -Status2 & Alarm2 535 -)))|(% style="width:96px" %)Total open door events2|(% style="width:126px" %)The last door open duration2 (unit: sec) 498 +((( 499 +* (% style="color:blue" %)**TDC flag** 536 536 537 - **Status1&Alarm1:**501 +When the flag is 1, it means sending packets at normal time intervals. 538 538 539 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:514px" %) 540 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:117px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:117px" %)**bit0** 541 -|(% style="width:76px" %)**Value**|(% style="width:96px" %)Reserve|(% style="width:99px" %)((( 542 -Count mod 543 -)))|(% style="width:103px" %)TDC flag 0:No;1:Yes|(% style="width:216px" %)((( 544 -Alarm1 0: No Alarm; 1: Alarm (PA8 of pin) 545 -)))|(% style="width:181px" %)((( 546 -Status1 0: Close; 1: Open (PA8 of pin) 503 +Otherwise, it is a packet sent at non-TDC time. 547 547 ))) 548 548 549 -**Status2 & Alarm2:** 506 +* ((( 507 +(% style="color:blue" %)**Total pulse** 508 +))) 550 550 551 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 552 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:200px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:200px" %)**bit0** 553 -|(% style="width:76px" %)**Value**|(% style="width:113px" %)Reserve|(% style="width:219px" %)((( 554 -Alarm2 0: No Alarm; 1: Alarm (PA4 of pin) 555 -)))|(% style="width:181px" %)((( 556 -Status2 0: Close; 1: Open (PA4 of pin) 510 +((( 511 +Total pulse/counting since factory 557 557 ))) 558 558 559 -[[image:image-20230630155908-6.png||height="295" width="927"]] 514 +((( 515 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 560 560 517 + 518 +))) 561 561 562 562 * ((( 563 -(% style="color:blue" %)** Countmod:Default=0**521 +(% style="color:blue" %)**Last Pulse** 564 564 ))) 565 565 566 -0: Uplink total open door times since factory 524 +((( 525 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 526 +))) 567 567 568 -1: Uplink total open door times since last FPORT=2 uplink. 528 +((( 529 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 569 569 570 570 571 -* (% style="color:blue" %)**TDC flag** 532 +* ((( 533 +(% style="color:blue" %)**PA4_status: Support digital level input below 3.3V** 534 +))) 572 572 573 -When the flag is 1, it means sending packets at normal time intervals. 536 +((( 537 +0 ~-~-> PA4 is at low level. 538 +))) 574 574 575 -Otherwise, it is a packet sent at non-TDC time. 540 +((( 541 +1 ~-~-> PA4 is at high level. 576 576 577 577 578 578 * ((( 579 -(% style="color: #0000ff" %)**Alarm1Alarm2**545 +(% style="color:blue" %)**PB15_status: Support digital level input below 3.3V** 580 580 ))) 581 581 582 -See [[Alarm Base on Timeout>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 548 +((( 549 +0 ~-~-> PB15 is at low level. 550 +))) 583 583 552 +((( 553 +1 ~-~-> PB15 is at high level.. 554 +))) 555 +))) 556 +))) 584 584 585 585 * ((( 586 -(% style="color:blue" %)** Status1 **(% style="color:#0000ff" %)**or **(% style="color:blue" %)**Status2**559 +(% style="color:blue" %)**MOD: Default =0** 587 587 ))) 588 588 589 -This bit is 1 when the door sensor is open and 0 when it is close. 562 +((( 563 +MOD=0 ~-~-> Uplink Total Pulse since factory 564 +))) 590 590 566 +((( 567 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 591 591 569 + 570 +))) 571 + 592 592 * ((( 593 -(% style="color:blue" %)** Total open door events1 **(% style="color:#0000ff"%)**or**(% style="color:blue"%)** Totalopen door events2**573 +(% style="color:blue" %)**Water Flow Value** 594 594 ))) 595 595 596 -Total pulse/counting base on open door. 576 +((( 577 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 578 +))) 597 597 598 - Range(3 Bytes):0x000000~~0xFFFFFF . Max:16777215580 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 599 599 600 600 601 - *(((602 - (% style="color:blue" %)**Thelastdoor openduration1**(%style="color:#0000ff"%)**or**(%style="color:blue"%)** Thelastdoor open duration2**583 +((( 584 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 603 603 ))) 604 604 605 - Doorsensorlastpenuration.587 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 606 606 607 -Unit: sec. 608 608 609 - [[image:image-20230701094042-1.png||height="154"width="763"]]590 +=== 2.3.3 Historical Water Flow Status, FPORT~=3 === 610 610 611 611 612 -=== 2.3.4 Historical Door Open/Close Event, FPORT~=3 === 593 +((( 594 +SW3L-NB stores sensor values and users can retrieve these history values via the downlink command. 595 +))) 613 613 597 +((( 598 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 614 614 615 -DS03A-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 600 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 601 +|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value, FPORT=3** 602 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 603 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 604 +Total pulse Or Last Pulse 605 +)))|(% style="width:78px" %)((( 606 +MOD & PA4_status & PB15_status 607 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)Unix TimeStamp 616 616 617 - The historicalpayload includes one or multiplies entriesand every entry has thesame payloadasReal-Time open/close status.609 +**Calculate Flag & Alarm:** 618 618 619 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 620 -|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0;width:515px" %)**Real-Time Open/Close Status, FPORT=3** 621 -|(% style="width:60px" %)**Size(bytes)**|(% style="width:80px" %)**1**|(% style="width:120px" %)**3**|(% style="width:150px" %)**3**|(% style="width:90px" %)**4** 622 -|(% style="width:95px" %)**Value**|(% style="width:97px" %)((( 623 -Status & [[Alarm>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 624 -)))|(% style="width:95px" %)Total open door events|(% style="width:119px" %)((( 625 -The last door open duration (unit: sec) 626 -)))|(% style="width:108px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 611 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 612 +|(% style="background-color:#4f81bd; color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:89px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:89px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:69px" %)**[bit5:bit2]**|(% style="background-color:#4f81bd; color:white; width:129px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:89px" %)**bit0** 613 +|(% style="width:88px" %)**Value**|(% style="width:96px" %)((( 614 +No ACK message 615 +)))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes 627 627 628 -** Status &Alarm:**617 +**MOD & PA4_status & PB15_status:** 629 629 630 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 631 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:65px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**[bit5:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**bit0** 632 -|(% style="width:76px" %)**Value**|(% style="width:88px" %)No ACK message|(% style="width:92px" %)Poll Message Flag|(% style="width:89px" %)Reserve|(% style="width:90px" %)((( 633 -Count mod 634 -)))|(% style="width:95px" %)((( 635 -TDC flag 0:No; 1:Yes 636 -)))|(% style="width:116px" %)((( 637 -Alarm 0: No Alarm; 1: Alarm 638 -)))|(% style="width:112px" %)((( 639 -Status 0:Close; 1: Open 619 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %) 620 +|(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:60px" %)**[bit5:bit0]** 621 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 640 640 ))) 641 641 642 642 * ((( 643 -Each data entry is 11 bytes and has the same structure as [[ Real-Timeopen/closestatus>>||anchor="H2.3.3A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery,DS03A-NBwill send max bytes according to the current DR and Frequency bands.625 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.2A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 644 644 ))) 645 645 628 +((( 646 646 For example, in the US915 band, the max payload for different DR is: 630 +))) 647 647 648 648 ((( 649 -** ~1.DR0**:max is 11 bytes so one entry of data633 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 650 650 ))) 651 651 652 652 ((( 653 -** 2.DR1**:max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)637 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 654 654 ))) 655 655 656 656 ((( 657 -** 3.DR2**:total payload includes 11 entries of data641 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 658 658 ))) 659 659 660 660 ((( 661 -** 4.DR3**:total payload includes 22 entries of data.645 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 662 662 ))) 663 663 664 -If DS03A-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0 648 +((( 649 +If SW3L-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0 665 665 666 -[[image:image-20230630155556-4.png||height="146" width="938"]] 651 + 652 +))) 667 667 668 -**Downlink:** 654 +((( 655 +(% style="color:#037691" %)**Downlink:** 656 +))) 669 669 670 -0x31 64 9E 7D 34 64 9E 7E 9C 05 658 +((( 659 +0x31 64 92 C5 AC 64 92 C7 8C 05 660 +))) 671 671 662 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230626093440-2.png?width=890&height=160&rev=1.1||alt="image-20230626093440-2.png"]] 672 672 673 -**Uplink:** 674 674 675 -45 00 00 00 00 00 00 64 9E 7D 48 40 00 00 00 00 00 63 64 9E 7D 9C 41 00 00 01 00 00 63 64 9E 7D A4 40 00 00 01 00 00 8D 64 9E 7E 31 43 00 00 02 00 00 8D 64 9E 7E 44 48 00 00 02 00 00 1F 64 9E 7E 59 4B 00 00 03 00 00 1F 64 9E 7E 6B 665 +((( 666 +(% style="color:#037691" %)**Uplink:** 667 +))) 676 676 669 +((( 670 +41 00 01 00 00 00 08 64 92 C5 E4 40 00 01 00 00 00 08 64 92 C6 06 49 41 01 00 00 00 00 64 92 C6 8B 49 81 01 00 00 00 00 64 92 C7 34 4A 01 01 00 00 00 2D 64 92 C7 7C 677 677 678 -**Parsed Value:** 672 + 673 +))) 679 679 680 -[COUNTMOD, TDC_FLAG, ALARM, DOOR_STATUS, OPEN_DOOR_TIMES, LAST_DOOR_OPEN_DURATION, TIME] 675 +((( 676 +(% style="color:#037691" %)**Parsed Value:** 677 +))) 681 681 679 +((( 680 +[TDC_flag, Alarm, Calculate Flag, PA4_status, PB15_status, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 681 +))) 682 682 683 -[SUM,YES,FALSE,OPEN,0,0,2023-06-30 06:59:20], 684 684 685 -[SUM,NO,FALSE,CLOSE,0,99,2023-06-30 07:00:44], 684 +((( 685 +[YES,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:41:56], 686 686 687 -[ SUM,NO,FALSE,OPEN,1,99,2023-06-3007:00:52],687 +[NO,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:42:30], 688 688 689 -[S UM,NO,FALSE,CLOSE,1,141,2023-06-3007:03:13],689 +[YES,FALSE,2,L,H,1,0, 0.0,2023-06-21 09:44:43], 690 690 691 -[S UM,NO,TRUE,OPEN,2,141,2023-06-3007:03:32],691 +[YES,FALSE,2,H,L,1,0, 0.0,2023-06-21 09:47:32], 692 692 693 -[PART,NO,FALSE,CLOSE,2,31,2023-06-30 07:03:53], 693 +[NO,TRUE ,2, L,L,1,45,0.7,2023-06-21 09:48:44], 694 +))) 694 694 695 -[ PART,NO,TRUE,OPEN,3,31,2023-06-3007:04:11],696 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230626093703-3.png?width=894&height=156&rev=1.1||alt="image-20230626093703-3.png"]] 696 696 697 -[[image:image-20230630172740-1.png||height="199" width="868"]] 698 698 699 - 700 - 701 701 == 2.4 Test Uplink and Change Update Interval == 702 702 703 703 ... ... @@ -713,7 +713,7 @@ 713 713 == 2.5 Multi-Samplings and One uplink == 714 714 715 715 716 -To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:714 +To save battery life, SW3L-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 717 717 718 718 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 719 719 ... ... @@ -727,7 +727,7 @@ 727 727 == 2.6 Trggier an uplink by external interrupt == 728 728 729 729 730 - DS03A-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.728 +SW3L-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets. 731 731 732 732 (% style="color:blue" %)**AT command:** 733 733 ... ... @@ -761,7 +761,7 @@ 761 761 ))) 762 762 763 763 ((( 764 -Default: 15s, If DS03A-NB didn't see any water flow in 15s,DS03A-NB will consider stop of water flow event.762 +Default: 15s, If SW3L-NB didn't see any water flow in 15s, SW3L-NB will consider stop of water flow event. 765 765 ))) 766 766 767 767 * ((( ... ... @@ -769,7 +769,7 @@ 769 769 ))) 770 770 771 771 ((( 772 -**Example:** 3 minutes, if DS03A-NB detect a start of water flow event and didn't detect a stop event within Alarm timer,DS03A-NB will send an Alarm to indicate a water flow abnormal alarm.770 +**Example:** 3 minutes, if SW3L-NB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-NB will send an Alarm to indicate a water flow abnormal alarm. 773 773 ))) 774 774 775 775 ((( ... ... @@ -896,12 +896,12 @@ 896 896 897 897 ))) 898 898 899 -= 3. Configure DS03A-NB =897 += 3. Configure SW3L-NB = 900 900 901 901 == 3.1 Configure Methods == 902 902 903 903 904 - DS03A-NB supports below configure method:902 +SW3L-NB supports below configure method: 905 905 906 906 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 907 907 ... ... @@ -990,7 +990,7 @@ 990 990 = 4. Battery & Power Consumption = 991 991 992 992 993 - DS03A-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.991 +SW3L-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 994 994 995 995 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 996 996 ... ... @@ -1025,7 +1025,7 @@ 1025 1025 = 7. Order Info = 1026 1026 1027 1027 1028 -Part Number: (% style="color:blue" %)** DS03A-NB-XX**1026 +Part Number: (% style="color:blue" %)**SW3L-NB-XX-YY** 1029 1029 1030 1030 (% style="color:red" %)**XX**(%%): 1031 1031 ... ... @@ -1035,14 +1035,43 @@ 1035 1035 1036 1036 (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 1037 1037 1036 +((( 1037 +(% style="color:blue" %)**YY**(%%): Flow Sensor Model: 1038 +))) 1038 1038 1040 +((( 1041 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1042 +))) 1039 1039 1044 +((( 1045 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1046 +))) 1047 + 1048 +((( 1049 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1050 +))) 1051 + 1052 +* ((( 1053 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1054 +))) 1055 + 1056 +* ((( 1057 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1058 +))) 1059 + 1060 +* ((( 1061 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1062 + 1063 + 1064 + 1065 +))) 1066 + 1040 1040 = 8. Packing Info = 1041 1041 1042 1042 1043 1043 (% style="color:#037691" %)**Package Includes**: 1044 1044 1045 -* DS03A-NB NB-IoT Doorsensor x 11072 +* SW3L-NB NB-IoT Distance Detection sensor x 1 1046 1046 1047 1047 * External antenna x 1 1048 1048