... ... @@ -15,15 +15,19 @@
15 15  
16 16  = 1. Introduction =
17 17  
18 -== 1.1 What is SW3L-NB NB-IoT Flow Sensor ==
18 +== 1.1 What is DS03A-NB NB-IoT Door Sensor ==
19 19  
20 20  
21 -The Dragino SW3L-NB is a (% style="color:blue" %)**NB-IoT Flow Sensor**(%%). It detects water flow volume and uplink to IoT server via NB-IoT network. User can use this to (% style="color:blue" %)**monitor the water usage for buildings**.
21 +The Dragino DS03A-NB is a (% style="color:blue" %) **NB-IoT Door Sensor**(%%) for Internet of Things solution. It (% style="color:blue" %)**detects door open/close status**(%%) and uplinks to IoT server via NB-IoT network. user can see the door status, open duration, open counts in the IoT Server.
22 22  
23 -The SW3L-NB will send water flow volume every 20 minutes. It can also detect the (% style="color:blue" %)**water flow status and send Alarm**(%%), to avoid the waste for water usage such as broken toilet case.
23 +The DS03A-NB will send periodically data every 2 hours as well as for each door open/close action. It also counts the door open times and calculates the last door open duration. Users can also disable the uplink for each open/close event, instead, DS03A-NB can count each open event and uplink periodically.
24 24  
25 -SW3L-NB is designed for both indoor and outdoor use. It has a weatherproof enclosure and industrial level battery to (% style="color:blue" %)**work in low to high temperatures**.
25 +DS03A-LB supports (% style="color:blue" %)**Datalog Feature,** (%%)it can save the data when there is no NB-IoT network and uplink when network recover.
26 26  
27 +DS03A-LB has the (% style="color:blue" %)**Open Alarm Feature**,(%%) user can set this feature so the device will send an alarm if the door has been open for a certain time.
28 +
29 +DS03A-LB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures
30 +
27 27  SW3L-NB supports different uplink methods including (% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%) for different application requirement, and support uplinks to various IoT Servers.
28 28  
29 29  SW3L-NB (% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%) which make user easy to use.
... ... @@ -32,7 +32,7 @@
32 32  
33 33  SW3L-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration.
34 34  
35 -[[image:image-20231010091546-2.png||height="348" width="909"]]
39 +[[image:image-20231011093807-6.png||height="278" width="879"]]
36 36  
37 37  
38 38  == 1.2 ​Features ==
... ... @@ -41,7 +41,10 @@
41 41  * NB-IoT Bands: B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 @H-FDD
42 42  * Ultra-low power consumption
43 43  * Upload water flow volume
44 -* Monitor water waste
48 +* Door Open/Close detect
49 +* Door open/close statistics
50 +* Datalog Feature
51 +* Open Alarm Feature
45 45  * Multiply Sampling and one uplink
46 46  * Support Bluetooth v5.1 remote configure and update firmware
47 47  * Uplink on periodically
... ... @@ -49,7 +49,6 @@
49 49  * 8500mAh Battery for long term use
50 50  * Nano SIM card slot for NB-IoT SIM
51 51  
52 -
53 53  == 1.3 Specification ==
54 54  
55 55  
... ... @@ -99,28 +99,11 @@
99 99  (% style="display:none" %) (%%)
100 100  
101 101  
102 -== 1.4 Flow Sensor Spec ==
108 +== 1.4 Applications ==
103 103  
104 104  
105 -(((
106 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
107 -|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Model**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Probe**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Diameter**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Range**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Max Pressure**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Measure**
108 -|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L
109 -|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L
110 -|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L
111 -)))
111 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654741400370-813.png?rev=1.1||alt="1654741400370-813.png"]]
112 112  
113 -
114 -
115 -== 1.5 Applications ==
116 -
117 -
118 -* Flow Sensor application
119 -* Water Control
120 -* Toilet Flow Sensor
121 -* Monitor Waste water
122 -
123 -
124 124  == 1.6 Sleep mode and working mode ==
125 125  
126 126  
... ... @@ -148,7 +148,6 @@
148 148  )))
149 149  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
150 150  
151 -
152 152  == 1.8 BLE connection ==
153 153  
154 154  
... ... @@ -310,7 +310,6 @@
310 310  
311 311  * Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Water Flow, Sampling time.
312 312  
313 -
314 314  === 2.2.2 HEX format Payload(Type~=0) ===
315 315  
316 316  
... ... @@ -754,7 +754,6 @@
754 754  
755 755  * (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
756 756  
757 -
758 758  == 2.7 Alarm for continuously water flow ==
759 759  
760 760  
... ... @@ -847,7 +847,6 @@
847 847  
848 848  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
849 849  
850 -
851 851  == 2.9 Set count number ==
852 852  
853 853  
... ... @@ -866,7 +866,6 @@
866 866  
867 867  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
868 868  
869 -
870 870  == 2.10 Set Transmit Interval Time ==
871 871  
872 872  
... ... @@ -923,7 +923,6 @@
923 923  
924 924  * AT Command via UART Connection : See [[UART Connection>>http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]].
925 925  
926 -
927 927  == 3.2 AT Commands Set ==
928 928  
929 929  
... ... @@ -1029,7 +1029,6 @@
1029 1029  
1030 1030  * Update through UART TTL interface : **[[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]**.
1031 1031  
1032 -
1033 1033  = 6. FAQ =
1034 1034  
1035 1035  == 6.1 How can I access t BC660K-GL AT Commands? ==
... ... @@ -1103,7 +1103,6 @@
1103 1103  
1104 1104  * Weight / pcs : 180g
1105 1105  
1106 -
1107 1107  = 9. Support =
1108 1108  
1109 1109