Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -151,7 +151,7 @@ 151 151 == 1.8 BLE connection == 152 152 153 153 154 - DDS45-NB support BLE remote configure and firmware update.154 +SW3L-NB support BLE remote configure and firmware update. 155 155 156 156 157 157 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -224,7 +224,7 @@ 224 224 == 2.1 Send data to IoT server via NB-IoT network == 225 225 226 226 227 -The DDS45-NB is equipped with a NB-IoT module, the pre-loaded firmware inDDS45-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined byDDS45-NB.227 +The SW3L-NB is equipped with a NB-IoT module, the pre-loaded firmware in SW3L-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by SW3L-NB. 228 228 229 229 230 230 Below shows the network structure: ... ... @@ -232,10 +232,10 @@ 232 232 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-NB_NB-IoT_Flow_Sensor_User_Manual/WebHome/image-20231010091546-2.png?width=909&height=348&rev=1.1||alt="image-20231010091546-2.png"]] 233 233 234 234 235 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DDS45-NB.235 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of SW3L-NB. 236 236 237 237 238 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DDS45-NB send data to IoT server.238 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set SW3L-NB send data to IoT server. 239 239 240 240 * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]]. 241 241 ... ... @@ -265,13 +265,13 @@ 265 265 [[image:image-20230819113244-11.png||height="141" width="367"]] 266 266 )))|(% style="width:170px" %) 267 267 268 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DDS45-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].268 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate SW3L-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]]. 269 269 270 270 271 271 == 2.2 Payload Types == 272 272 273 273 274 -To meet different server requirement, DDS45-NB supports different payload type.274 +To meet different server requirement, SW3L-NB supports different payload type. 275 275 276 276 **Includes:** 277 277 ... ... @@ -297,7 +297,7 @@ 297 297 298 298 This is the General Json Format. As below: 299 299 300 -(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":" DDS45-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**300 +(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"SW3L-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}** 301 301 302 302 303 303 [[image:image-20230920175015-3.png||height="613" width="890"]] ... ... @@ -328,7 +328,7 @@ 328 328 329 329 These bytes include the hardware and software version. 330 330 331 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for DDS45-NB331 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for SW3L-NB 332 332 333 333 (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 1.0.0 334 334 ... ... @@ -372,12 +372,11 @@ 372 372 373 373 Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard. 374 374 375 -(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": " DDS45-NB","distance": 502,"battery": 3.57,"signal": 23}**375 +(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "SW3L","distance": 502,"battery": 3.57,"signal": 23}** 376 376 377 377 [[image:image-20230922094043-2.png||height="558" width="851"]] 378 378 379 379 380 -=== === 381 381 382 382 === 2.2.4 ThingSpeak Payload(Type~=1) === 383 383 ... ... @@ -395,77 +395,331 @@ 395 395 396 396 == 2.3 Uplink Payload == 397 397 397 +=== 2.3.1 Sensor Configuration, FPORT~=4 === 398 398 399 + 400 +SW3L-LB will only send this command after getting the downlink command **(0x26 02)** from the server. 401 + 402 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 403 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1** 404 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 405 + 406 +Example parse in TTNv3 407 + 408 +[[image:image-20230614172555-4.png||height="151" width="853"]] 409 + 410 + 411 +* (% style="color:blue" %)**TDC: (default: 0x0004B0)** 412 + 413 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 414 + 415 + 416 +* (% style="color:blue" %)**STOP Duration & Alarm Timer** 417 + 418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 419 + 420 + 421 +=== 2.3.2 Water Flow Value, Uplink FPORT~=2 === 422 + 423 + 399 399 ((( 400 - DDS45-NB will uplinkpayloadvia LoRaWANwithbelow payloadformat:425 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will: 401 401 ))) 402 402 403 403 ((( 404 - Uplinkpayloadincludes intotal21bytes.429 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]]. 405 405 ))) 406 406 407 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 408 -|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)8|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 49px;" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 79px;" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)4 409 -|(% style="width:95px" %)Value|(% style="width:61px" %)f+IMEI|(% style="width:61px" %)Ver|(% style="width:61px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(% style="width:61px" %)((( 410 -Singal 432 +((( 433 +Uplink Payload totals 11 bytes. 434 +))) 411 411 412 -Strength 413 -)))|(% style="width:49px" %)Mod|(% style="width:79px" %)[[Digital Interrupt >>||anchor="H2.3.2A0Interrupt"]]|(% style="width:61px" %)[[Distance>>||anchor="H2.3.3A0Distance"]](unit: mm)|(% style="width:61px" %)((( 414 -Timestamp 436 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 437 +|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=2** 438 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 439 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 440 +Total pulse Or Last Pulse 441 +)))|(% style="width:78px" %)((( 442 +MOD & PA4_status & PB15_status 443 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 415 415 445 +**Calculate Flag & Alarm:** 446 + 447 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 448 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**[bit7:bit6]**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**bit0** 449 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes 450 + 451 +**MOD & PA4_status & PB15_status:** 452 + 453 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %) 454 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]** 455 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 456 + 457 +(% style="color:#037691" %)** **[[image:image-20230626093242-1.png||height="276" width="892"]] 458 + 459 + 460 +* ((( 461 +(% style="color:blue" %)**Calculate Flag** 462 +))) 463 + 464 +((( 465 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 466 + 416 416 417 417 ))) 418 418 419 -If the cache upload mechanism is turned on, you will receive the payload shown in the figure below. 470 +((( 471 +**Example: in the default payload:** 472 +))) 420 420 421 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:512px" %) 422 -|(% style="width:115px" %)**Frame header**|(% style="width:118px" %)**Frame data(1)**|(% style="width:116px" %)**Frame data(2)**|(% style="width:39px" %)**F…**|(% style="width:117px" %)**Frame data(X)** 474 +* ((( 475 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 476 +))) 477 +* ((( 478 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 479 +))) 480 +* ((( 481 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 482 +))) 423 423 424 -=== === 484 +((( 485 +Default value: 0. 486 +))) 425 425 426 -=== 2.3.1 Battery Info === 488 +((( 489 +Range (4 bits): (b)0000 ~~ (b) 1111 427 427 491 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 428 428 429 - CheckthebatteryvoltageforDDS45-NB.493 +1) User can set the Calculate Flag of this sensor to 3. 430 430 431 -Ex1: 0x0B45 = 2885mV 495 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 496 +))) 432 432 433 -Ex2: 0x0B49 = 2889mV 498 +((( 499 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.5Setthecalculateflag"]] 434 434 501 +((( 502 + 503 +))) 504 +))) 435 435 436 -=== 2.3.2 Interrupt === 437 437 507 +* ((( 508 +(% style="color:blue" %)**Alarm** 509 +))) 438 438 439 -This data field shows if this packet is generated by interrupt or not. 511 +((( 512 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]] 513 +))) 440 440 441 - **Example:**515 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 442 442 443 -0x00: Normal uplink packet. 444 444 445 -0x01: Interrupt Uplink Packet. 518 +((( 519 +* (% style="color:blue" %)**TDC flag** 446 446 521 +When the flag is 1, it means sending packets at normal time intervals. 447 447 448 -=== 2.3.3 Distance === 523 +Otherwise, it is a packet sent at non-TDC time. 524 +))) 449 449 526 +* ((( 527 +(% style="color:blue" %)**Total pulse** 528 +))) 450 450 451 451 ((( 452 - Getthedistance.Flat objectange 30mm - 4500mm.531 +Total pulse/counting since factory 453 453 ))) 454 454 455 455 ((( 456 - For example,ifthe datayou getfrom theregisteris**0x0B0x05**,the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **535 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 457 457 458 - (%style="color:blue" %)**0B05(H) = 2821 (D) = 2821 mm.**537 + 459 459 ))) 460 460 461 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 540 +* ((( 541 +(% style="color:blue" %)**Last Pulse** 542 +))) 462 462 463 -* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 544 +((( 545 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 546 +))) 464 464 465 465 ((( 549 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 550 + 551 + 552 +* ((( 553 +(% style="color:blue" %)**PA4_status: Support digital level input below 3.3V** 554 +))) 555 + 556 +((( 557 +0 ~-~-> PA4 is at low level. 558 +))) 559 + 560 +((( 561 +1 ~-~-> PA4 is at high level. 562 + 563 + 564 +* ((( 565 +(% style="color:blue" %)**PB15_status: Support digital level input below 3.3V** 566 +))) 567 + 568 +((( 569 +0 ~-~-> PB15 is at low level. 570 +))) 571 + 572 +((( 573 +1 ~-~-> PB15 is at high level.. 574 +))) 575 +))) 576 +))) 577 + 578 +* ((( 579 +(% style="color:blue" %)**MOD: Default =0** 580 +))) 581 + 582 +((( 583 +MOD=0 ~-~-> Uplink Total Pulse since factory 584 +))) 585 + 586 +((( 587 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 588 + 466 466 467 467 ))) 468 468 592 +* ((( 593 +(% style="color:blue" %)**Water Flow Value** 594 +))) 595 + 596 +((( 597 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 598 +))) 599 + 600 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 601 + 602 + 603 +((( 604 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 605 +))) 606 + 607 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 608 + 609 + 610 +=== 2.3.3 Historical Water Flow Status, FPORT~=3 === 611 + 612 + 613 +((( 614 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 615 +))) 616 + 617 +((( 618 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 619 + 620 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 621 +|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value, FPORT=3** 622 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 623 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 624 +Total pulse Or Last Pulse 625 +)))|(% style="width:78px" %)((( 626 +MOD & PA4_status & PB15_status 627 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 628 + 629 +**Calculate Flag & Alarm:** 630 + 631 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 632 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:129px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit0** 633 +|(% style="width:88px" %)**Value**|(% style="width:96px" %)((( 634 +No ACK message 635 +)))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes 636 + 637 +**MOD & PA4_status & PB15_status:** 638 + 639 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %) 640 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]** 641 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 642 +))) 643 + 644 +* ((( 645 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 646 +))) 647 + 648 +((( 649 +For example, in the US915 band, the max payload for different DR is: 650 +))) 651 + 652 +((( 653 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 654 +))) 655 + 656 +((( 657 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 658 +))) 659 + 660 +((( 661 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 662 +))) 663 + 664 +((( 665 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 666 +))) 667 + 668 +((( 669 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0 670 + 671 + 672 +))) 673 + 674 +((( 675 +(% style="color:#037691" %)**Downlink:** 676 +))) 677 + 678 +((( 679 +0x31 64 92 C5 AC 64 92 C7 8C 05 680 +))) 681 + 682 +[[image:image-20230626093440-2.png||height="160" width="890"]] 683 + 684 + 685 +((( 686 +(% style="color:#037691" %)**Uplink:** 687 +))) 688 + 689 +((( 690 +41 00 01 00 00 00 08 64 92 C5 E4 40 00 01 00 00 00 08 64 92 C6 06 49 41 01 00 00 00 00 64 92 C6 8B 49 81 01 00 00 00 00 64 92 C7 34 4A 01 01 00 00 00 2D 64 92 C7 7C 691 + 692 + 693 +))) 694 + 695 +((( 696 +(% style="color:#037691" %)**Parsed Value:** 697 +))) 698 + 699 +((( 700 +[TDC_flag, Alarm, Calculate Flag, PA4_status, PB15_status, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 701 +))) 702 + 703 + 704 +((( 705 +[YES,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:41:56], 706 + 707 +[NO,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:42:30], 708 + 709 +[YES,FALSE,2,L,H,1,0, 0.0,2023-06-21 09:44:43], 710 + 711 +[YES,FALSE,2,H,L,1,0, 0.0,2023-06-21 09:47:32], 712 + 713 +[NO,TRUE ,2, L,L,1,45,0.7,2023-06-21 09:48:44], 714 + 715 + 716 +))) 717 + 718 +[[image:image-20230626093703-3.png||height="156" width="894"]] 719 + 720 + 721 + 469 469 == 2.4 Test Uplink and Change Update Interval == 470 470 471 471 ... ... @@ -481,7 +481,7 @@ 481 481 == 2.5 Multi-Samplings and One uplink == 482 482 483 483 484 -To save battery life, DDS45-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:737 +To save battery life, SW3L-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 485 485 486 486 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 487 487 ... ... @@ -495,7 +495,7 @@ 495 495 == 2.6 Trggier an uplink by external interrupt == 496 496 497 497 498 - DDS45-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.751 +SW3L-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets. 499 499 500 500 (% style="color:blue" %)**AT command:** 501 501 ... ... @@ -509,12 +509,12 @@ 509 509 510 510 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 511 511 512 -= 3. Configure DDS45-NB =765 += 3. Configure SW3L-NB = 513 513 514 514 == 3.1 Configure Methods == 515 515 516 516 517 - DDS45-NB supports below configure method:770 +SW3L-NB supports below configure method: 518 518 519 519 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 520 520 ... ... @@ -603,7 +603,7 @@ 603 603 = 4. Battery & Power Consumption = 604 604 605 605 606 - DDS45-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.859 +SW3L-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 607 607 608 608 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 609 609 ... ... @@ -635,10 +635,10 @@ 635 635 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 636 636 637 637 638 -== 6.2 Can I use DDS45-NB in condensation environment? ==891 +== 6.2 Can I use SW3L-NB in condensation environment? == 639 639 640 640 641 - DDS45-NB is not suitable to be used in condensation environment. Condensation on theDDS45-NB probe will affect the reading and always got 0.894 +SW3L-NB is not suitable to be used in condensation environment. Condensation on the SW3L-NB probe will affect the reading and always got 0. 642 642 643 643 644 644 = 7. Trouble Shooting = ... ... @@ -677,7 +677,7 @@ 677 677 = 8. Order Info = 678 678 679 679 680 -Part Number: (% style="color:blue" %)** DDS45-NB-XX**933 +Part Number: (% style="color:blue" %)**SW3L-NB-XX-YY** 681 681 682 682 (% style="color:red" %)**XX**(%%): 683 683 ... ... @@ -687,13 +687,43 @@ 687 687 688 688 (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 689 689 943 +((( 944 +(% style="color:blue" %)**YY**(%%): Flow Sensor Model: 945 +))) 690 690 947 +((( 948 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 949 +))) 950 + 951 +((( 952 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 953 +))) 954 + 955 +((( 956 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 957 +))) 958 + 959 +* ((( 960 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 961 +))) 962 + 963 +* ((( 964 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 965 +))) 966 + 967 +* ((( 968 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 969 + 970 + 971 + 972 +))) 973 + 691 691 = 9. Packing Info = 692 692 693 693 694 694 (% style="color:#037691" %)**Package Includes**: 695 695 696 -* DDS45-NB NB-IoT Distance Detection sensor x 1979 +* SW3L-NB NB-IoT Distance Detection sensor x 1 697 697 698 698 * External antenna x 1 699 699