Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 101.8
edited by Xiaoling
on 2023/10/10 11:56
Change comment: There is no comment for this version
To version 101.11
edited by Xiaoling
on 2023/10/10 14:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -151,7 +151,7 @@
151 151  == 1.8 BLE connection ==
152 152  
153 153  
154 -DDS45-NB support BLE remote configure and firmware update.
154 +SW3L-NB support BLE remote configure and firmware update.
155 155  
156 156  
157 157  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
... ... @@ -224,7 +224,7 @@
224 224  == 2.1 Send data to IoT server via NB-IoT network ==
225 225  
226 226  
227 -The DDS45-NB is equipped with a NB-IoT module, the pre-loaded firmware in DDS45-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by DDS45-NB.
227 +The SW3L-NB is equipped with a NB-IoT module, the pre-loaded firmware in SW3L-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by SW3L-NB.
228 228  
229 229  
230 230  Below shows the network structure:
... ... @@ -232,10 +232,10 @@
232 232  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-NB_NB-IoT_Flow_Sensor_User_Manual/WebHome/image-20231010091546-2.png?width=909&height=348&rev=1.1||alt="image-20231010091546-2.png"]]
233 233  
234 234  
235 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DDS45-NB.
235 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of SW3L-NB.
236 236  
237 237  
238 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DDS45-NB send data to IoT server.
238 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set SW3L-NB send data to IoT server.
239 239  
240 240  * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]].
241 241  
... ... @@ -265,13 +265,13 @@
265 265  [[image:image-20230819113244-11.png||height="141" width="367"]]
266 266  )))|(% style="width:170px" %)
267 267  
268 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DDS45-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].
268 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate SW3L-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].
269 269  
270 270  
271 271  == 2.2 ​Payload Types ==
272 272  
273 273  
274 -To meet different server requirement, DDS45-NB supports different payload type.
274 +To meet different server requirement, SW3L-NB supports different payload type.
275 275  
276 276  **Includes:**
277 277  
... ... @@ -297,7 +297,7 @@
297 297  
298 298  This is the General Json Format. As below:
299 299  
300 -(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"DDS45-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**
300 +(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"SW3L-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**
301 301  
302 302  
303 303  [[image:image-20230920175015-3.png||height="613" width="890"]]
... ... @@ -328,7 +328,7 @@
328 328  
329 329  These bytes include the hardware and software version.
330 330  
331 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for DDS45-NB
331 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for SW3L-NB
332 332  
333 333  (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 1.0.0
334 334  
... ... @@ -372,12 +372,11 @@
372 372  
373 373  Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard.
374 374  
375 -(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "DDS45-NB","distance": 502,"battery": 3.57,"signal": 23}**
375 +(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "SW3L","distance": 502,"battery": 3.57,"signal": 23}**
376 376  
377 377  [[image:image-20230922094043-2.png||height="558" width="851"]]
378 378  
379 379  
380 -=== ===
381 381  
382 382  === 2.2.4 ThingSpeak Payload(Type~=1) ===
383 383  
... ... @@ -395,77 +395,331 @@
395 395  
396 396  == 2.3  ​Uplink Payload ==
397 397  
397 +=== 2.3.1 Sensor Configuration, FPORT~=4 ===
398 398  
399 +
400 +SW3L-LB will only send this command after getting the downlink command **(0x26 02)** from the server.
401 +
402 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
403 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
404 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
405 +
406 +Example parse in TTNv3
407 +
408 +[[image:image-20230614172555-4.png||height="151" width="853"]]
409 +
410 +
411 +* (% style="color:blue" %)**TDC: (default: 0x0004B0)**
412 +
413 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes.
414 +
415 +
416 +* (% style="color:blue" %)**STOP Duration & Alarm Timer**
417 +
418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
419 +
420 +
421 +=== 2.3.2 Water Flow Value, Uplink FPORT~=2 ===
422 +
423 +
399 399  (((
400 -DDS45-NB will uplink payload via LoRaWAN with below payload format: 
425 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will:
401 401  )))
402 402  
403 403  (((
404 -Uplink payload includes in total 21 bytes.
429 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
405 405  )))
406 406  
407 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
408 -|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)8|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 49px;" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 79px;" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)4
409 -|(% style="width:95px" %)Value|(% style="width:61px" %)f+IMEI|(% style="width:61px" %)Ver|(% style="width:61px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(% style="width:61px" %)(((
410 -Singal
432 +(((
433 +Uplink Payload totals 11 bytes.
434 +)))
411 411  
412 -Strength
413 -)))|(% style="width:49px" %)Mod|(% style="width:79px" %)[[Digital Interrupt >>||anchor="H2.3.2A0Interrupt"]]|(% style="width:61px" %)[[Distance>>||anchor="H2.3.3A0Distance"]](unit: mm)|(% style="width:61px" %)(((
414 -Timestamp
436 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
437 +|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
438 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4**
439 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
440 +Total pulse Or Last Pulse
441 +)))|(% style="width:78px" %)(((
442 +MOD & PA4_status & PB15_status
443 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
415 415  
445 +**Calculate Flag & Alarm:**
446 +
447 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
448 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**[bit7:bit6]**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**bit0**
449 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes
450 +
451 +**MOD & PA4_status & PB15_status:**
452 +
453 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %)
454 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]**
455 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD
456 +
457 +(% style="color:#037691" %)** **[[image:image-20230626093242-1.png||height="276" width="892"]]
458 +
459 +
460 +* (((
461 +(% style="color:blue" %)**Calculate Flag**
462 +)))
463 +
464 +(((
465 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
466 +
416 416  
417 417  )))
418 418  
419 -If the cache upload mechanism is turned on, you will receive the payload shown in the figure below.
470 +(((
471 +**Example: in the default payload:**
472 +)))
420 420  
421 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:512px" %)
422 -|(% style="width:115px" %)**Frame header**|(% style="width:118px" %)**Frame data(1)**|(% style="width:116px" %)**Frame data(2)**|(% style="width:39px" %)**F…**|(% style="width:117px" %)**Frame data(X)**
474 +* (((
475 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
476 +)))
477 +* (((
478 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
479 +)))
480 +* (((
481 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L
482 +)))
423 423  
424 -=== ===
484 +(((
485 +Default value: 0. 
486 +)))
425 425  
426 -=== 2.3.1  Battery Info ===
488 +(((
489 +Range (4 bits): (b)0000 ~~ (b) 1111
427 427  
491 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server,
428 428  
429 -Check the battery voltage for DDS45-NB.
493 +1) User can set the Calculate Flag of this sensor to 3.
430 430  
431 -Ex1: 0x0B45 = 2885mV
495 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count.
496 +)))
432 432  
433 -Ex2: 0x0B49 = 2889mV
498 +(((
499 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.5Setthecalculateflag"]]
434 434  
501 +(((
502 +
503 +)))
504 +)))
435 435  
436 -=== 2.3.2  Interrupt ===
437 437  
507 +* (((
508 +(% style="color:blue" %)**Alarm**
509 +)))
438 438  
439 -This data field shows if this packet is generated by interrupt or not.
511 +(((
512 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
513 +)))
440 440  
441 -**Example:**
515 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
442 442  
443 -0x00: Normal uplink packet.
444 444  
445 -0x01: Interrupt Uplink Packet.
518 +(((
519 +* (% style="color:blue" %)**TDC flag**
446 446  
521 +When the flag is 1, it means sending packets at normal time intervals.
447 447  
448 -=== 2.3.3  Distance ===
523 +Otherwise, it is a packet sent at non-TDC time.
524 +)))
449 449  
526 +* (((
527 +(% style="color:blue" %)**Total pulse**
528 +)))
450 450  
451 451  (((
452 -Get the distance. Flat object range 30mm - 4500mm.
531 +Total pulse/counting since factory
453 453  )))
454 454  
455 455  (((
456 -For example, if the data you get from the register is **0x0B 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
535 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
457 457  
458 -(% style="color:blue" %)**0B05(H) = 2821 (D) = 2821 mm.**
537 +
459 459  )))
460 460  
461 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
540 +* (((
541 +(% style="color:blue" %)**Last Pulse**
542 +)))
462 462  
463 -* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
544 +(((
545 +Total pulse since last FPORT=2 uplink. (Default 20 minutes)
546 +)))
464 464  
465 465  (((
549 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
550 +
551 +
552 +* (((
553 +(% style="color:blue" %)**PA4_status: Support digital level input below 3.3V**
554 +)))
555 +
556 +(((
557 +0 ~-~-> PA4 is at low level.
558 +)))
559 +
560 +(((
561 +1 ~-~-> PA4 is at high level.
562 +
563 +
564 +* (((
565 +(% style="color:blue" %)**PB15_status: Support digital level input below 3.3V**
566 +)))
567 +
568 +(((
569 +0 ~-~-> PB15 is at low level.
570 +)))
571 +
572 +(((
573 +1 ~-~-> PB15 is at high level..
574 +)))
575 +)))
576 +)))
577 +
578 +* (((
579 +(% style="color:blue" %)**MOD: Default =0**
580 +)))
581 +
582 +(((
583 +MOD=0 ~-~-> Uplink Total Pulse since factory
584 +)))
585 +
586 +(((
587 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink.
588 +
466 466  
467 467  )))
468 468  
592 +* (((
593 +(% style="color:blue" %)**Water Flow Value**
594 +)))
595 +
596 +(((
597 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L**
598 +)))
599 +
600 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]
601 +
602 +
603 +(((
604 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L**
605 +)))
606 +
607 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **
608 +
609 +
610 +=== 2.3.3 Historical Water Flow Status, FPORT~=3 ===
611 +
612 +
613 +(((
614 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
615 +)))
616 +
617 +(((
618 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
619 +
620 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
621 +|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=3**
622 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4**
623 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
624 +Total pulse Or Last Pulse
625 +)))|(% style="width:78px" %)(((
626 +MOD & PA4_status & PB15_status
627 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
628 +
629 +**Calculate Flag & Alarm:**
630 +
631 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
632 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:129px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit0**
633 +|(% style="width:88px" %)**Value**|(% style="width:96px" %)(((
634 +No ACK message
635 +)))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes
636 +
637 +**MOD & PA4_status & PB15_status:**
638 +
639 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %)
640 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]**
641 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD
642 +)))
643 +
644 +* (((
645 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
646 +)))
647 +
648 +(((
649 +For example, in the US915 band, the max payload for different DR is:
650 +)))
651 +
652 +(((
653 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data
654 +)))
655 +
656 +(((
657 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
658 +)))
659 +
660 +(((
661 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data
662 +)))
663 +
664 +(((
665 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data.
666 +)))
667 +
668 +(((
669 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
670 +
671 +
672 +)))
673 +
674 +(((
675 +(% style="color:#037691" %)**Downlink:**
676 +)))
677 +
678 +(((
679 +0x31 64 92 C5 AC 64 92 C7 8C 05
680 +)))
681 +
682 +[[image:image-20230626093440-2.png||height="160" width="890"]]
683 +
684 +
685 +(((
686 +(% style="color:#037691" %)**Uplink:**
687 +)))
688 +
689 +(((
690 +41 00 01 00 00 00 08 64 92 C5 E4 40 00 01 00 00 00 08 64 92 C6 06 49 41 01 00 00 00 00 64 92 C6 8B 49 81 01 00 00 00 00 64 92 C7 34 4A 01 01 00 00 00 2D 64 92 C7 7C
691 +
692 +
693 +)))
694 +
695 +(((
696 +(% style="color:#037691" %)**Parsed Value:**
697 +)))
698 +
699 +(((
700 +[TDC_flag, Alarm, Calculate Flag, PA4_status, PB15_status, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME]
701 +)))
702 +
703 +
704 +(((
705 +[YES,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:41:56],
706 +
707 +[NO,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:42:30],
708 +
709 +[YES,FALSE,2,L,H,1,0, 0.0,2023-06-21 09:44:43],
710 +
711 +[YES,FALSE,2,H,L,1,0, 0.0,2023-06-21 09:47:32],
712 +
713 +[NO,TRUE ,2, L,L,1,45,0.7,2023-06-21 09:48:44],
714 +
715 +
716 +)))
717 +
718 +[[image:image-20230626093703-3.png||height="156" width="894"]]
719 +
720 +
721 +
469 469  == 2.4 Test Uplink and Change Update Interval ==
470 470  
471 471  
... ... @@ -481,7 +481,7 @@
481 481  == 2.5 Multi-Samplings and One uplink ==
482 482  
483 483  
484 -To save battery life, DDS45-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
737 +To save battery life, SW3L-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
485 485  
486 486  * (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
487 487  
... ... @@ -495,7 +495,7 @@
495 495  == 2.6 Trggier an uplink by external interrupt ==
496 496  
497 497  
498 -DDS45-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.
751 +SW3L-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.
499 499  
500 500  (% style="color:blue" %)**AT command:**
501 501  
... ... @@ -509,12 +509,12 @@
509 509  
510 510  * (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
511 511  
512 -= 3. Configure DDS45-NB =
765 += 3. Configure SW3L-NB =
513 513  
514 514  == 3.1 Configure Methods ==
515 515  
516 516  
517 -DDS45-NB supports below configure method:
770 +SW3L-NB supports below configure method:
518 518  
519 519  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
520 520  
... ... @@ -603,7 +603,7 @@
603 603  = 4. Battery & Power Consumption =
604 604  
605 605  
606 -DDS45-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
859 +SW3L-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
607 607  
608 608  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
609 609  
... ... @@ -635,10 +635,10 @@
635 635  [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
636 636  
637 637  
638 -== 6.2 Can I use DDS45-NB in condensation environment? ==
891 +== 6.2 Can I use SW3L-NB in condensation environment? ==
639 639  
640 640  
641 -DDS45-NB is not suitable to be used in condensation environment. Condensation on the DDS45-NB probe will affect the reading and always got 0.
894 +SW3L-NB is not suitable to be used in condensation environment. Condensation on the SW3L-NB probe will affect the reading and always got 0.
642 642  
643 643  
644 644  = 7. Trouble Shooting =
... ... @@ -677,7 +677,7 @@
677 677  = 8. Order Info =
678 678  
679 679  
680 -Part Number: (% style="color:blue" %)**DDS45-NB-XX**
933 +Part Number: (% style="color:blue" %)**SW3L-NB-XX-YY**
681 681  
682 682  (% style="color:red" %)**XX**(%%):
683 683  
... ... @@ -687,13 +687,43 @@
687 687  
688 688  (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands
689 689  
943 +(((
944 +(% style="color:blue" %)**YY**(%%): Flow Sensor Model:
945 +)))
690 690  
947 +(((
948 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
949 +)))
950 +
951 +(((
952 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
953 +)))
954 +
955 +(((
956 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
957 +)))
958 +
959 +* (((
960 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
961 +)))
962 +
963 +* (((
964 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
965 +)))
966 +
967 +* (((
968 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
969 +
970 +
971 +
972 +)))
973 +
691 691  = 9. ​Packing Info =
692 692  
693 693  
694 694  (% style="color:#037691" %)**Package Includes**:
695 695  
696 -* DDS45-NB NB-IoT Distance Detection sensor x 1
979 +* SW3L-NB NB-IoT Distance Detection sensor x 1
697 697  
698 698  * External antenna x 1
699 699