Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 101.6
edited by Xiaoling
on 2023/10/10 10:37
Change comment: There is no comment for this version
To version 101.15
edited by Xiaoling
on 2023/10/10 15:38
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -101,15 +101,27 @@
101 101  (% class="wikigeneratedid" id="H1.4Ratedenvironmentalconditions" %)
102 102  (% style="display:none" %) (%%)
103 103  
104 -== 1.4 Applications ==
104 +== 1.4 Flow Sensor Spec ==
105 105  
106 106  
107 +(((
108 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
109 +|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure**
110 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L
111 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L
112 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L
113 +)))
114 +
115 +
116 +== 1.5 Applications ==
117 +
118 +
107 107  * Flow Sensor application
108 108  * Water Control
109 109  * Toilet Flow Sensor
110 110  * Monitor Waste water
111 111  
112 -== 1.5 Sleep mode and working mode ==
124 +== 1.6 Sleep mode and working mode ==
113 113  
114 114  
115 115  (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any NB-IoT activate. This mode is used for storage and shipping to save battery life.
... ... @@ -117,7 +117,7 @@
117 117  (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as NB-IoT Sensor to Join NB-IoT network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
118 118  
119 119  
120 -== 1.6 Button & LEDs ==
132 +== 1.7 Button & LEDs ==
121 121  
122 122  
123 123  [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]]
... ... @@ -136,10 +136,10 @@
136 136  )))
137 137  |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode.
138 138  
139 -== 1.9 BLE connection ==
151 +== 1.8 BLE connection ==
140 140  
141 141  
142 -DDS45-NB support BLE remote configure and firmware update.
154 +SW3L-NB support BLE remote configure and firmware update.
143 143  
144 144  
145 145  BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
... ... @@ -151,7 +151,7 @@
151 151  If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
152 152  
153 153  
154 -== 1.10 Pin Definitions & Switch ==
166 +== 1.9 Pin Definitions & Switch ==
155 155  
156 156  
157 157  [[image:image-20230819104805-5.png]]
... ... @@ -188,18 +188,31 @@
188 188  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143909447-639.png?rev=1.1||alt="1675143909447-639.png"]]
189 189  
190 190  
191 -(% style="color:blue" %)**Probe Mechanical:**
192 192  
193 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS45%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654915562090-396.png?rev=1.1||alt="1654915562090-396.png"]]
204 +**Probe Mechanical:**
194 194  
195 195  
207 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L**
196 196  
197 -= 2. Use DDS45-NB to communicate with IoT Server =
209 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]]
198 198  
211 +
212 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20.  390 pulse = 1 L**
213 +
214 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]]
215 +
216 +
217 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L**
218 +
219 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]]
220 +
221 +
222 += 2. Use SW3L-NB to communicate with IoT Server =
223 +
199 199  == 2.1 Send data to IoT server via NB-IoT network ==
200 200  
201 201  
202 -The DDS45-NB is equipped with a NB-IoT module, the pre-loaded firmware in DDS45-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by DDS45-NB.
227 +The SW3L-NB is equipped with a NB-IoT module, the pre-loaded firmware in SW3L-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by SW3L-NB.
203 203  
204 204  
205 205  Below shows the network structure:
... ... @@ -207,10 +207,10 @@
207 207  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-NB_NB-IoT_Flow_Sensor_User_Manual/WebHome/image-20231010091546-2.png?width=909&height=348&rev=1.1||alt="image-20231010091546-2.png"]]
208 208  
209 209  
210 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DDS45-NB.
235 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of SW3L-NB.
211 211  
212 212  
213 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DDS45-NB send data to IoT server.
238 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set SW3L-NB send data to IoT server.
214 214  
215 215  * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]].
216 216  
... ... @@ -240,13 +240,13 @@
240 240  [[image:image-20230819113244-11.png||height="141" width="367"]]
241 241  )))|(% style="width:170px" %)
242 242  
243 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DDS45-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].
268 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate SW3L-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].
244 244  
245 245  
246 246  == 2.2 ​Payload Types ==
247 247  
248 248  
249 -To meet different server requirement, DDS45-NB supports different payload type.
274 +To meet different server requirement, SW3L-NB supports different payload type.
250 250  
251 251  **Includes:**
252 252  
... ... @@ -272,7 +272,7 @@
272 272  
273 273  This is the General Json Format. As below:
274 274  
275 -(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"DDS45-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**
300 +(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"SW3L-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**
276 276  
277 277  
278 278  [[image:image-20230920175015-3.png||height="613" width="890"]]
... ... @@ -303,7 +303,7 @@
303 303  
304 304  These bytes include the hardware and software version.
305 305  
306 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for DDS45-NB
331 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for SW3L-NB
307 307  
308 308  (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 1.0.0
309 309  
... ... @@ -347,12 +347,11 @@
347 347  
348 348  Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard.
349 349  
350 -(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "DDS45-NB","distance": 502,"battery": 3.57,"signal": 23}**
375 +(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "SW3L","distance": 502,"battery": 3.57,"signal": 23}**
351 351  
352 352  [[image:image-20230922094043-2.png||height="558" width="851"]]
353 353  
354 354  
355 -=== ===
356 356  
357 357  === 2.2.4 ThingSpeak Payload(Type~=1) ===
358 358  
... ... @@ -370,77 +370,331 @@
370 370  
371 371  == 2.3  ​Uplink Payload ==
372 372  
397 +=== 2.3.1 Sensor Configuration, FPORT~=4 ===
373 373  
399 +
400 +SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server.
401 +
402 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
403 +|(% style="background-color:#4F81BD;color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:105px" %)**3**|(% style="background-color:#4F81BD;color:white; width:60px" %)**1**|(% style="background-color:#4F81BD;color:white; width:96px" %)**1**|(% style="background-color:#4F81BD;color:white; width:105px" %)**2**|(% style="background-color:#4F81BD;color:white; width:74px" %)**1**
404 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
405 +
406 +Example parse in TTNv3
407 +
408 +[[image:image-20230614172555-4.png||height="151" width="853"]]
409 +
410 +
411 +* (% style="color:blue" %)**TDC: (default: 0x0004B0)**
412 +
413 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes.
414 +
415 +
416 +* (% style="color:blue" %)**STOP Duration & Alarm Timer**
417 +
418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
419 +
420 +
421 +=== 2.3.2 Water Flow Value, Uplink FPORT~=2 ===
422 +
423 +
374 374  (((
375 -DDS45-NB will uplink payload via LoRaWAN with below payload format: 
425 +SW3L-NB will send this uplink **after** Device Status once join the NB-IoT network successfully. And SW3L-NB will:
376 376  )))
377 377  
378 378  (((
379 -Uplink payload includes in total 21 bytes.
429 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
380 380  )))
381 381  
382 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
383 -|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)8|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 49px;" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 79px;" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)4
384 -|(% style="width:95px" %)Value|(% style="width:61px" %)f+IMEI|(% style="width:61px" %)Ver|(% style="width:61px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(% style="width:61px" %)(((
385 -Singal
432 +(((
433 +Uplink Payload totals 11 bytes.
434 +)))
386 386  
387 -Strength
388 -)))|(% style="width:49px" %)Mod|(% style="width:79px" %)[[Digital Interrupt >>||anchor="H2.3.2A0Interrupt"]]|(% style="width:61px" %)[[Distance>>||anchor="H2.3.3A0Distance"]](unit: mm)|(% style="width:61px" %)(((
389 -Timestamp
436 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
437 +|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
438 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4**
439 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
440 +Total pulse Or Last Pulse
441 +)))|(% style="width:78px" %)(((
442 +MOD & PA4_status & PB15_status
443 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
390 390  
445 +**Calculate Flag & Alarm:**
446 +
447 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
448 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**[bit7:bit6]**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**bit0**
449 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes
450 +
451 +**MOD & PA4_status & PB15_status:**
452 +
453 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %)
454 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]**
455 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD
456 +
457 +(% style="color:#037691" %)** **[[image:image-20230626093242-1.png||height="276" width="892"]]
458 +
459 +
460 +* (((
461 +(% style="color:blue" %)**Calculate Flag**
462 +)))
463 +
464 +(((
465 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
466 +
391 391  
392 392  )))
393 393  
394 -If the cache upload mechanism is turned on, you will receive the payload shown in the figure below.
470 +(((
471 +**Example: in the default payload:**
472 +)))
395 395  
396 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:512px" %)
397 -|(% style="width:115px" %)**Frame header**|(% style="width:118px" %)**Frame data(1)**|(% style="width:116px" %)**Frame data(2)**|(% style="width:39px" %)**F…**|(% style="width:117px" %)**Frame data(X)**
474 +* (((
475 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
476 +)))
477 +* (((
478 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
479 +)))
480 +* (((
481 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L
482 +)))
398 398  
399 -=== ===
484 +(((
485 +Default value: 0. 
486 +)))
400 400  
401 -=== 2.3.1  Battery Info ===
488 +(((
489 +Range (4 bits): (b)0000 ~~ (b) 1111
402 402  
491 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server,
403 403  
404 -Check the battery voltage for DDS45-NB.
493 +1) User can set the Calculate Flag of this sensor to 3.
405 405  
406 -Ex1: 0x0B45 = 2885mV
495 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count.
496 +)))
407 407  
408 -Ex2: 0x0B49 = 2889mV
498 +(((
499 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.5Setthecalculateflag"]]
409 409  
501 +(((
502 +
503 +)))
504 +)))
410 410  
411 -=== 2.3.2  Interrupt ===
412 412  
507 +* (((
508 +(% style="color:blue" %)**Alarm**
509 +)))
413 413  
414 -This data field shows if this packet is generated by interrupt or not.
511 +(((
512 +See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
513 +)))
415 415  
416 -**Example:**
515 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
417 417  
418 -0x00: Normal uplink packet.
419 419  
420 -0x01: Interrupt Uplink Packet.
518 +(((
519 +* (% style="color:blue" %)**TDC flag**
421 421  
521 +When the flag is 1, it means sending packets at normal time intervals.
422 422  
423 -=== 2.3.3  Distance ===
523 +Otherwise, it is a packet sent at non-TDC time.
524 +)))
424 424  
526 +* (((
527 +(% style="color:blue" %)**Total pulse**
528 +)))
425 425  
426 426  (((
427 -Get the distance. Flat object range 30mm - 4500mm.
531 +Total pulse/counting since factory
428 428  )))
429 429  
430 430  (((
431 -For example, if the data you get from the register is **0x0B 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
535 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
432 432  
433 -(% style="color:blue" %)**0B05(H) = 2821 (D) = 2821 mm.**
537 +
434 434  )))
435 435  
436 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor.
540 +* (((
541 +(% style="color:blue" %)**Last Pulse**
542 +)))
437 437  
438 -* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
544 +(((
545 +Total pulse since last FPORT=2 uplink. (Default 20 minutes)
546 +)))
439 439  
440 440  (((
549 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF .
550 +
551 +
552 +* (((
553 +(% style="color:blue" %)**PA4_status: Support digital level input below 3.3V**
554 +)))
555 +
556 +(((
557 +0 ~-~-> PA4 is at low level.
558 +)))
559 +
560 +(((
561 +1 ~-~-> PA4 is at high level.
562 +
563 +
564 +* (((
565 +(% style="color:blue" %)**PB15_status: Support digital level input below 3.3V**
566 +)))
567 +
568 +(((
569 +0 ~-~-> PB15 is at low level.
570 +)))
571 +
572 +(((
573 +1 ~-~-> PB15 is at high level..
574 +)))
575 +)))
576 +)))
577 +
578 +* (((
579 +(% style="color:blue" %)**MOD: Default =0**
580 +)))
581 +
582 +(((
583 +MOD=0 ~-~-> Uplink Total Pulse since factory
584 +)))
585 +
586 +(((
587 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink.
588 +
441 441  
442 442  )))
443 443  
592 +* (((
593 +(% style="color:blue" %)**Water Flow Value**
594 +)))
595 +
596 +(((
597 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L**
598 +)))
599 +
600 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]
601 +
602 +
603 +(((
604 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L**
605 +)))
606 +
607 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **
608 +
609 +
610 +=== 2.3.3 Historical Water Flow Status, FPORT~=3 ===
611 +
612 +
613 +(((
614 +SW3L-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
615 +)))
616 +
617 +(((
618 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
619 +
620 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
621 +|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=3**
622 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4**
623 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
624 +Total pulse Or Last Pulse
625 +)))|(% style="width:78px" %)(((
626 +MOD & PA4_status & PB15_status
627 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]
628 +
629 +**Calculate Flag & Alarm:**
630 +
631 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
632 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:129px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit0**
633 +|(% style="width:88px" %)**Value**|(% style="width:96px" %)(((
634 +No ACK message
635 +)))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes
636 +
637 +**MOD & PA4_status & PB15_status:**
638 +
639 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %)
640 +|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]**
641 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD
642 +)))
643 +
644 +* (((
645 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
646 +)))
647 +
648 +(((
649 +For example, in the US915 band, the max payload for different DR is:
650 +)))
651 +
652 +(((
653 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data
654 +)))
655 +
656 +(((
657 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)
658 +)))
659 +
660 +(((
661 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data
662 +)))
663 +
664 +(((
665 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data.
666 +)))
667 +
668 +(((
669 +If SW3L-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0
670 +
671 +
672 +)))
673 +
674 +(((
675 +(% style="color:#037691" %)**Downlink:**
676 +)))
677 +
678 +(((
679 +0x31 64 92 C5 AC 64 92 C7 8C 05
680 +)))
681 +
682 +[[image:image-20230626093440-2.png||height="160" width="890"]]
683 +
684 +
685 +(((
686 +(% style="color:#037691" %)**Uplink:**
687 +)))
688 +
689 +(((
690 +41 00 01 00 00 00 08 64 92 C5 E4 40 00 01 00 00 00 08 64 92 C6 06 49 41 01 00 00 00 00 64 92 C6 8B 49 81 01 00 00 00 00 64 92 C7 34 4A 01 01 00 00 00 2D 64 92 C7 7C
691 +
692 +
693 +)))
694 +
695 +(((
696 +(% style="color:#037691" %)**Parsed Value:**
697 +)))
698 +
699 +(((
700 +[TDC_flag, Alarm, Calculate Flag, PA4_status, PB15_status, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME]
701 +)))
702 +
703 +
704 +(((
705 +[YES,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:41:56],
706 +
707 +[NO,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:42:30],
708 +
709 +[YES,FALSE,2,L,H,1,0, 0.0,2023-06-21 09:44:43],
710 +
711 +[YES,FALSE,2,H,L,1,0, 0.0,2023-06-21 09:47:32],
712 +
713 +[NO,TRUE ,2, L,L,1,45,0.7,2023-06-21 09:48:44],
714 +
715 +
716 +)))
717 +
718 +[[image:image-20230626093703-3.png||height="156" width="894"]]
719 +
720 +
721 +
444 444  == 2.4 Test Uplink and Change Update Interval ==
445 445  
446 446  
... ... @@ -456,7 +456,7 @@
456 456  == 2.5 Multi-Samplings and One uplink ==
457 457  
458 458  
459 -To save battery life, DDS45-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
737 +To save battery life, SW3L-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:
460 460  
461 461  * (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds)
462 462  
... ... @@ -470,7 +470,7 @@
470 470  == 2.6 Trggier an uplink by external interrupt ==
471 471  
472 472  
473 -DDS45-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.
751 +SW3L-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.
474 474  
475 475  (% style="color:blue" %)**AT command:**
476 476  
... ... @@ -484,12 +484,122 @@
484 484  
485 485  * (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
486 486  
487 -= 3. Configure DDS45-NB =
765 +== 2.7 Alarm for continuously water flow ==
488 488  
767 +
768 +(((
769 +This feature is to monitor and send Alarm for continuously water flow.
770 +)))
771 +
772 +(((
773 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water.
774 +)))
775 +
776 +(((
777 +To monitor this faulty and send alarm, there are two settings:
778 +)))
779 +
780 +* (((
781 +(% style="color:blue" %)**Stop Duration: Unit: Second**
782 +)))
783 +
784 +(((
785 +Default: 15s, If SW3L-NB didn't see any water flow in 15s, SW3L-NB will consider stop of water flow event.
786 +)))
787 +
788 +* (((
789 +(% style="color:blue" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)**
790 +)))
791 +
792 +(((
793 +**Example:** 3 minutes, if SW3L-NB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-NB will send an Alarm to indicate a water flow abnormal alarm.
794 +)))
795 +
796 +(((
797 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform.
798 +)))
799 +
800 +(((
801 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.**
802 +)))
803 +
804 +(((
805 +(% style="color:blue" %)**AT Command to configure:**
806 +)))
807 +
808 +* (((
809 +AT+PTRIG=15,3  ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes.
810 +)))
811 +
812 +* (((
813 +AT+ PTRIG=15,0  ~-~-> Default Value, disable water waste Alarm.
814 +)))
815 +
816 +(((
817 +(% style="color:blue" %)**Downlink Command to configure:** 
818 +)))
819 +
820 +(((
821 +Command: **0xAA aa bb cc**
822 +)))
823 +
824 +(((
825 +AA: Command Type Code
826 +)))
827 +
828 +(((
829 +aa: Stop duration
830 +)))
831 +
832 +(((
833 +bb cc: Alarm Timer
834 +)))
835 +
836 +(((
837 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3
838 +)))
839 +
840 +
841 +== 2.8 Set the calculate flag ==
842 +
843 +
844 +Feature: Set the calculate flag
845 +
846 +(% style="color:blue" %)**AT Command: AT+CALCFLAG**
847 +
848 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
849 +|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
850 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
851 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
852 +
853 +(% style="color:blue" %)**Downlink Command:**
854 +
855 +* **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
856 +
857 +== 2.9 Set count number ==
858 +
859 +
860 +Feature: Manually set the count number
861 +
862 +(% style="color:blue" %)**AT Command: AT+SETCNT**
863 +
864 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
865 +|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
866 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
867 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
868 +
869 +(% style="color:blue" %)**Downlink Command:**
870 +
871 +* **Example**: 0xA6000001  ~/~/  Same as AT+ SETCNT =1
872 +
873 +* **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
874 +
875 += 3. Configure SW3L-NB =
876 +
489 489  == 3.1 Configure Methods ==
490 490  
491 491  
492 -DDS45-NB supports below configure method:
880 +SW3L-NB supports below configure method:
493 493  
494 494  * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
495 495  
... ... @@ -578,7 +578,7 @@
578 578  = 4. Battery & Power Consumption =
579 579  
580 580  
581 -DDS45-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
969 +SW3L-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
582 582  
583 583  [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
584 584  
... ... @@ -610,10 +610,10 @@
610 610  [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
611 611  
612 612  
613 -== 6.2 Can I use DDS45-NB in condensation environment? ==
1001 +== 6.2 Can I use SW3L-NB in condensation environment? ==
614 614  
615 615  
616 -DDS45-NB is not suitable to be used in condensation environment. Condensation on the DDS45-NB probe will affect the reading and always got 0.
1004 +SW3L-NB is not suitable to be used in condensation environment. Condensation on the SW3L-NB probe will affect the reading and always got 0.
617 617  
618 618  
619 619  = 7. Trouble Shooting =
... ... @@ -652,7 +652,7 @@
652 652  = 8. Order Info =
653 653  
654 654  
655 -Part Number: (% style="color:blue" %)**DDS45-NB-XX**
1043 +Part Number: (% style="color:blue" %)**SW3L-NB-XX-YY**
656 656  
657 657  (% style="color:red" %)**XX**(%%):
658 658  
... ... @@ -662,13 +662,43 @@
662 662  
663 663  (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands
664 664  
1053 +(((
1054 +(% style="color:blue" %)**YY**(%%): Flow Sensor Model:
1055 +)))
665 665  
1057 +(((
1058 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15.  450 pulse = 1 L
1059 +)))
1060 +
1061 +(((
1062 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L
1063 +)))
1064 +
1065 +(((
1066 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L
1067 +)))
1068 +
1069 +* (((
1070 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L
1071 +)))
1072 +
1073 +* (((
1074 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L
1075 +)))
1076 +
1077 +* (((
1078 +calculate flag=2: for SW3L-010 Flow Sensor: 64  pulse = 1 L
1079 +
1080 +
1081 +
1082 +)))
1083 +
666 666  = 9. ​Packing Info =
667 667  
668 668  
669 669  (% style="color:#037691" %)**Package Includes**:
670 670  
671 -* DDS45-NB NB-IoT Distance Detection sensor x 1
1089 +* SW3L-NB NB-IoT Distance Detection sensor x 1
672 672  
673 673  * External antenna x 1
674 674