Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -50,7 +50,6 @@ 50 50 * Support Bluetooth v5.1 remote configure and update firmware 51 51 * Uplink on periodically 52 52 * Downlink to change configure 53 -* IP66 Waterproof Enclosure 54 54 * 8500mAh Battery for long term use 55 55 * Nano SIM card slot for NB-IoT SIM 56 56 ... ... @@ -102,15 +102,27 @@ 102 102 (% class="wikigeneratedid" id="H1.4Ratedenvironmentalconditions" %) 103 103 (% style="display:none" %) (%%) 104 104 105 -== 1. 6Applications ==104 +== 1.4 Flow Sensor Spec == 106 106 107 107 107 +((( 108 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 109 +|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Model**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Probe**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Diameter**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Range**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Max Pressure**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Measure** 110 +|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 111 +|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 112 +|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 113 +))) 114 + 115 + 116 +== 1.5 Applications == 117 + 118 + 108 108 * Flow Sensor application 109 109 * Water Control 110 110 * Toilet Flow Sensor 111 111 * Monitor Waste water 112 112 113 -== 1. 7Sleep mode and working mode ==124 +== 1.6 Sleep mode and working mode == 114 114 115 115 116 116 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any NB-IoT activate. This mode is used for storage and shipping to save battery life. ... ... @@ -118,7 +118,7 @@ 118 118 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as NB-IoT Sensor to Join NB-IoT network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 119 119 120 120 121 -== 1. 8Button & LEDs ==132 +== 1.7 Button & LEDs == 122 122 123 123 124 124 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -137,10 +137,10 @@ 137 137 ))) 138 138 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 139 139 140 -== 1. 9BLE connection ==151 +== 1.8 BLE connection == 141 141 142 142 143 - DDS45-NB support BLE remote configure and firmware update.154 +SW3L-NB support BLE remote configure and firmware update. 144 144 145 145 146 146 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -152,7 +152,7 @@ 152 152 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 153 153 154 154 155 -== 1. 10Pin Definitions & Switch ==166 +== 1.9 Pin Definitions & Switch == 156 156 157 157 158 158 [[image:image-20230819104805-5.png]] ... ... @@ -189,18 +189,31 @@ 189 189 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143909447-639.png?rev=1.1||alt="1675143909447-639.png"]] 190 190 191 191 192 -(% style="color:blue" %)**Probe Mechanical:** 193 193 194 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS45%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/1654915562090-396.png?rev=1.1||alt="1654915562090-396.png"]]204 +**Probe Mechanical:** 195 195 196 196 207 +(% style="color:blue" %)**DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L** 197 197 198 - = 2.DDS45-NBtocommunicateIoT Server=209 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 199 199 211 + 212 +(% style="color:blue" %)**006: DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L** 213 + 214 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 215 + 216 + 217 +(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 218 + 219 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 220 + 221 + 222 += 2. Use SW3L-NB to communicate with IoT Server = 223 + 200 200 == 2.1 Send data to IoT server via NB-IoT network == 201 201 202 202 203 -The DDS45-NB is equipped with a NB-IoT module, the pre-loaded firmware inDDS45-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined byDDS45-NB.227 +The SW3L-NB is equipped with a NB-IoT module, the pre-loaded firmware in SW3L-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by SW3L-NB. 204 204 205 205 206 206 Below shows the network structure: ... ... @@ -208,10 +208,10 @@ 208 208 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-NB_NB-IoT_Flow_Sensor_User_Manual/WebHome/image-20231010091546-2.png?width=909&height=348&rev=1.1||alt="image-20231010091546-2.png"]] 209 209 210 210 211 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DDS45-NB.235 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of SW3L-NB. 212 212 213 213 214 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DDS45-NB send data to IoT server.238 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set SW3L-NB send data to IoT server. 215 215 216 216 * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]]. 217 217 ... ... @@ -241,13 +241,13 @@ 241 241 [[image:image-20230819113244-11.png||height="141" width="367"]] 242 242 )))|(% style="width:170px" %) 243 243 244 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DDS45-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].268 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate SW3L-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]]. 245 245 246 246 247 247 == 2.2 Payload Types == 248 248 249 249 250 -To meet different server requirement, DDS45-NB supports different payload type.274 +To meet different server requirement, SW3L-NB supports different payload type. 251 251 252 252 **Includes:** 253 253 ... ... @@ -273,7 +273,7 @@ 273 273 274 274 This is the General Json Format. As below: 275 275 276 -(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":" DDS45-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**300 +(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"SW3L-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}** 277 277 278 278 279 279 [[image:image-20230920175015-3.png||height="613" width="890"]] ... ... @@ -304,7 +304,7 @@ 304 304 305 305 These bytes include the hardware and software version. 306 306 307 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for DDS45-NB331 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x0b for SW3L-NB 308 308 309 309 (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 1.0.0 310 310 ... ... @@ -348,12 +348,11 @@ 348 348 349 349 Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard. 350 350 351 -(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": " DDS45-NB","distance": 502,"battery": 3.57,"signal": 23}**375 +(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "SW3L","distance": 502,"battery": 3.57,"signal": 23}** 352 352 353 353 [[image:image-20230922094043-2.png||height="558" width="851"]] 354 354 355 355 356 -=== === 357 357 358 358 === 2.2.4 ThingSpeak Payload(Type~=1) === 359 359 ... ... @@ -371,77 +371,329 @@ 371 371 372 372 == 2.3 Uplink Payload == 373 373 397 +=== 2.3.1 Sensor Configuration, FPORT~=4 === 374 374 399 + 400 +SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server. 401 + 402 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 403 +|(% style="background-color:#4F81BD;color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:105px" %)**3**|(% style="background-color:#4F81BD;color:white; width:60px" %)**1**|(% style="background-color:#4F81BD;color:white; width:96px" %)**1**|(% style="background-color:#4F81BD;color:white; width:105px" %)**2**|(% style="background-color:#4F81BD;color:white; width:74px" %)**1** 404 +|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 405 + 406 +Example parse in TTNv3 407 + 408 +[[image:image-20230614172555-4.png||height="151" width="853"]] 409 + 410 + 411 +* (% style="color:blue" %)**TDC: (default: 0x0004B0)** 412 + 413 +Uplink interval for the total pulse count, default value is 0x0004B0 which is 1200 seconds = 20 minutes. 414 + 415 + 416 +* (% style="color:blue" %)**STOP Duration & Alarm Timer** 417 + 418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]] 419 + 420 + 421 +=== 2.3.2 Water Flow Value, Uplink FPORT~=2 === 422 + 423 + 375 375 ((( 376 - DDS45-NB will uplinkpayloadviaLoRaWANwithbelowpayloadformat:425 +SW3L-NB will send this uplink **after** Device Status once join the NB-IoT network successfully. And SW3L-NB will: 377 377 ))) 378 378 379 379 ((( 380 - Uplinkpayloadincludes intotal21bytes.429 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H2.10SetTransmitIntervalTime"]]. 381 381 ))) 382 382 383 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 384 -|=(% style="width: 95px; background-color:#4F81BD;color:white" %)Size(bytes)|=(% style="width: 61px; background-color:#4F81BD;color:white" %)8|=(% style="width: 61px; background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 49px;" %)1|=(% style="background-color: rgb(79, 129, 189); color: white; width: 79px;" %)1|=(% style="background-color:#4F81BD;color:white" %)2|=(% style="background-color:#4F81BD;color:white" %)4 385 -|(% style="width:95px" %)Value|(% style="width:61px" %)f+IMEI|(% style="width:61px" %)Ver|(% style="width:61px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(% style="width:61px" %)((( 386 -Singal 432 +((( 433 +Uplink Payload totals 11 bytes. 434 +))) 387 387 388 -Strength 389 -)))|(% style="width:49px" %)Mod|(% style="width:79px" %)[[Digital Interrupt >>||anchor="H2.3.2A0Interrupt"]]|(% style="width:61px" %)[[Distance>>||anchor="H2.3.3A0Distance"]](unit: mm)|(% style="width:61px" %)((( 390 -Timestamp 436 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 437 +|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value, FPORT=2** 438 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 439 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 440 +Total pulse Or Last Pulse 441 +)))|(% style="width:78px" %)((( 442 +MOD & PA4_status & PB15_status 443 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 391 391 445 +**Calculate Flag & Alarm:** 446 + 447 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 448 +|(% style="background-color:#4F81BD;color:white; width:70px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:70px" %)**[bit7:bit6]**|(% style="background-color:#4F81BD;color:white; width:90px" %)**[bit5:bit2]**|(% style="background-color:#4F81BD;color:white; width:140px" %)**bit1**|(% style="background-color:#4F81BD;color:white; width:130px" %)**bit0** 449 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes 450 + 451 +**MOD & PA4_status & PB15_status:** 452 + 453 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %) 454 +|(% style="background-color:#4F81BD;color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit7**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit6**|(% style="background-color:#4F81BD;color:white; width:60px" %)**[bit5:bit0]** 455 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 456 + 457 +(% style="color:#037691" %)** **[[image:image-20230626093242-1.png||height="276" width="892"]] 458 + 459 + 460 +* ((( 461 +(% style="color:blue" %)**Calculate Flag** 462 +))) 463 + 464 +((( 465 +The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 466 +))) 467 + 468 +((( 469 +**Example: in the default payload:** 470 +))) 471 + 472 +* ((( 473 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 474 +))) 475 +* ((( 476 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 477 +))) 478 +* ((( 479 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 480 +))) 481 + 482 +((( 483 +Default value: 0. 484 +))) 485 + 486 +((( 487 +Range (4 bits): (b)0000 ~~ (b) 1111 488 + 489 +If user use with a meter for example is 0.02L/pulse. To proper decode the correct value in server, 490 + 491 +1) User can set the Calculate Flag of this sensor to 3. 492 + 493 +2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 494 +))) 495 + 496 +((( 497 +(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H3.3.5Setthecalculateflag"]] 498 + 499 +((( 392 392 393 393 ))) 502 +))) 394 394 395 -If the cache upload mechanism is turned on, you will receive the payload shown in the figure below. 396 396 397 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:512px" %) 398 -|(% style="width:115px" %)**Frame header**|(% style="width:118px" %)**Frame data(1)**|(% style="width:116px" %)**Frame data(2)**|(% style="width:39px" %)**F…**|(% style="width:117px" %)**Frame data(X)** 505 +* ((( 506 +(% style="color:blue" %)**Alarm** 507 +))) 399 399 400 -=== === 509 +((( 510 +See [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]] 511 +))) 401 401 402 - === 2.3.1 Battery Info513 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]] 403 403 404 404 405 -Check the battery voltage for DDS45-NB. 516 +((( 517 +* (% style="color:blue" %)**TDC flag** 406 406 407 - Ex1:0x0B45=2885mV519 +When the flag is 1, it means sending packets at normal time intervals. 408 408 409 -Ex2: 0x0B49 = 2889mV 521 +Otherwise, it is a packet sent at non-TDC time. 522 +))) 410 410 524 +* ((( 525 +(% style="color:blue" %)**Total pulse** 526 +))) 411 411 412 -=== 2.3.2 Interrupt === 528 +((( 529 +Total pulse/counting since factory 530 +))) 413 413 532 +((( 533 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 414 414 415 -This data field shows if this packet is generated by interrupt or not. 535 + 536 +))) 416 416 417 -**Example:** 538 +* ((( 539 +(% style="color:blue" %)**Last Pulse** 540 +))) 418 418 419 -0x00: Normal uplink packet. 542 +((( 543 +Total pulse since last FPORT=2 uplink. (Default 20 minutes) 544 +))) 420 420 421 -0x01: Interrupt Uplink Packet. 546 +((( 547 +Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 422 422 423 423 424 -=== 2.3.3 Distance === 550 +* ((( 551 +(% style="color:blue" %)**PA4_status: Support digital level input below 3.3V** 552 +))) 425 425 554 +((( 555 +0 ~-~-> PA4 is at low level. 556 +))) 426 426 427 427 ((( 428 -Get the distance. Flat object range 30mm - 4500mm. 559 +1 ~-~-> PA4 is at high level. 560 + 561 + 562 +* ((( 563 +(% style="color:blue" %)**PB15_status: Support digital level input below 3.3V** 429 429 ))) 430 430 431 431 ((( 432 -For example, if the data you get from the register is **0x0B 0x05**, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 567 +0 ~-~-> PB15 is at low level. 568 +))) 433 433 434 -(% style="color:blue" %)**0B05(H) = 2821 (D) = 2821 mm.** 570 +((( 571 +1 ~-~-> PB15 is at high level.. 435 435 ))) 573 +))) 574 +))) 436 436 437 -* If the sensor value is 0x0000, it means system doesn't detect ultrasonic sensor. 576 +* ((( 577 +(% style="color:blue" %)**MOD: Default =0** 578 +))) 438 438 439 -* If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 580 +((( 581 +MOD=0 ~-~-> Uplink Total Pulse since factory 582 +))) 440 440 441 441 ((( 585 +MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 586 + 442 442 443 443 ))) 444 444 590 +* ((( 591 +(% style="color:blue" %)**Water Flow Value** 592 +))) 593 + 594 +((( 595 +**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 596 +))) 597 + 598 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]] 599 + 600 + 601 +((( 602 +**Total Water Flow for TDC timer = (Calculate Flag) x (Last Pulse)=79/450=0.2L** 603 +))) 604 + 605 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** ** 606 + 607 + 608 +=== 2.3.3 Historical Water Flow Status, FPORT~=3 === 609 + 610 + 611 +((( 612 +SW3L-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 613 +))) 614 + 615 +((( 616 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 617 + 618 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 619 +|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value, FPORT=3** 620 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 621 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 622 +Total pulse Or Last Pulse 623 +)))|(% style="width:78px" %)((( 624 +MOD & PA4_status & PB15_status 625 +)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 626 + 627 +**Calculate Flag & Alarm:** 628 + 629 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 630 +|(% style="background-color:#4F81BD;color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:89px" %)**bit7**|(% style="background-color:#4F81BD;color:white; width:89px" %)**bit6**|(% style="background-color:#4F81BD;color:white; width:69px" %)**[bit5:bit2]**|(% style="background-color:#4F81BD;color:white; width:129px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit0** 631 +|(% style="width:88px" %)**Value**|(% style="width:96px" %)((( 632 +No ACK message 633 +)))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes 634 + 635 +**MOD & PA4_status & PB15_status:** 636 + 637 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %) 638 +|(% style="background-color:#4F81BD;color:white; width:60px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit7**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit6**|(% style="background-color:#4F81BD;color:white; width:60px" %)**[bit5:bit0]** 639 +|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 640 +))) 641 + 642 +* ((( 643 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.2A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands. 644 +))) 645 + 646 +((( 647 +For example, in the US915 band, the max payload for different DR is: 648 +))) 649 + 650 +((( 651 +(% style="color:blue" %)**a) DR0:**(%%) max is 11 bytes so one entry of data 652 +))) 653 + 654 +((( 655 +(% style="color:blue" %)**b) DR1:**(%%) max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 656 +))) 657 + 658 +((( 659 +(% style="color:blue" %)**c) DR2:**(%%) total payload includes 11 entries of data 660 +))) 661 + 662 +((( 663 +(% style="color:blue" %)**d) DR3:**(%%) total payload includes 22 entries of data. 664 +))) 665 + 666 +((( 667 +If SW3L-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0 668 + 669 + 670 +))) 671 + 672 +((( 673 +(% style="color:#037691" %)**Downlink:** 674 +))) 675 + 676 +((( 677 +0x31 64 92 C5 AC 64 92 C7 8C 05 678 +))) 679 + 680 +[[image:image-20230626093440-2.png||height="160" width="890"]] 681 + 682 + 683 +((( 684 +(% style="color:#037691" %)**Uplink:** 685 +))) 686 + 687 +((( 688 +41 00 01 00 00 00 08 64 92 C5 E4 40 00 01 00 00 00 08 64 92 C6 06 49 41 01 00 00 00 00 64 92 C6 8B 49 81 01 00 00 00 00 64 92 C7 34 4A 01 01 00 00 00 2D 64 92 C7 7C 689 + 690 + 691 +))) 692 + 693 +((( 694 +(% style="color:#037691" %)**Parsed Value:** 695 +))) 696 + 697 +((( 698 +[TDC_flag, Alarm, Calculate Flag, PA4_status, PB15_status, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 699 +))) 700 + 701 + 702 +((( 703 +[YES,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:41:56], 704 + 705 +[NO,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:42:30], 706 + 707 +[YES,FALSE,2,L,H,1,0, 0.0,2023-06-21 09:44:43], 708 + 709 +[YES,FALSE,2,H,L,1,0, 0.0,2023-06-21 09:47:32], 710 + 711 +[NO,TRUE ,2, L,L,1,45,0.7,2023-06-21 09:48:44], 712 + 713 + 714 +))) 715 + 716 +[[image:image-20230626093703-3.png||height="156" width="894"]] 717 + 718 + 719 + 445 445 == 2.4 Test Uplink and Change Update Interval == 446 446 447 447 ... ... @@ -457,7 +457,7 @@ 457 457 == 2.5 Multi-Samplings and One uplink == 458 458 459 459 460 -To save battery life, DDS45-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:735 +To save battery life, SW3L-NB will sample Distance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 461 461 462 462 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 463 463 ... ... @@ -471,7 +471,7 @@ 471 471 == 2.6 Trggier an uplink by external interrupt == 472 472 473 473 474 - DDS45-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.749 +SW3L-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets. 475 475 476 476 (% style="color:blue" %)**AT command:** 477 477 ... ... @@ -485,12 +485,164 @@ 485 485 486 486 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 487 487 488 -= 3.ConfigureDDS45-NB=763 +== 2.7 Alarm for continuously water flow == 489 489 765 + 766 +((( 767 +This feature is to monitor and send Alarm for continuously water flow. 768 +))) 769 + 770 +((( 771 +Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 772 +))) 773 + 774 +((( 775 +To monitor this faulty and send alarm, there are two settings: 776 +))) 777 + 778 +* ((( 779 +(% style="color:blue" %)**Stop Duration: Unit: Second** 780 +))) 781 + 782 +((( 783 +Default: 15s, If SW3L-NB didn't see any water flow in 15s, SW3L-NB will consider stop of water flow event. 784 +))) 785 + 786 +* ((( 787 +(% style="color:blue" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 788 +))) 789 + 790 +((( 791 +**Example:** 3 minutes, if SW3L-NB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-NB will send an Alarm to indicate a water flow abnormal alarm. 792 +))) 793 + 794 +((( 795 +So for example, If we set stop duration=15s and Alarm Timer=3minutes. If the toilet water flow continuously for more than 3 minutes, Sensor will send an alarm (in Confirmed MODE) to platform. 796 +))) 797 + 798 +((( 799 +(% style="color:red" %)**Note:** **After this alarm is send, sensor will consider a stop of water flow and count for another new event. So if water flow waste last for 1 hour, Sensor will keep sending alarm every 3 minutes.** 800 +))) 801 + 802 +((( 803 +(% style="color:blue" %)**AT Command to configure:** 804 +))) 805 + 806 +* ((( 807 +AT+PTRIG=15,3 ~-~-> Set Stop duration: 15s, Alarm Timer: 3 minutes. 808 +))) 809 + 810 +* ((( 811 +AT+ PTRIG=15,0 ~-~-> Default Value, disable water waste Alarm. 812 +))) 813 + 814 +((( 815 +(% style="color:blue" %)**Downlink Command to configure:** 816 +))) 817 + 818 +((( 819 +Command: **0xAA aa bb cc** 820 +))) 821 + 822 +((( 823 +AA: Command Type Code 824 +))) 825 + 826 +((( 827 +aa: Stop duration 828 +))) 829 + 830 +((( 831 +bb cc: Alarm Timer 832 +))) 833 + 834 +((( 835 +If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 836 +))) 837 + 838 + 839 +== 2.8 Set the calculate flag == 840 + 841 + 842 +Feature: Set the calculate flag 843 + 844 +(% style="color:blue" %)**AT Command: AT+CALCFLAG** 845 + 846 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 847 +|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 193px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Response** 848 +|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 849 +|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 850 + 851 +(% style="color:blue" %)**Downlink Command:** 852 + 853 +* **Example**: 0XA501 ~/~/ Same as AT+CALCFLAG =1 854 + 855 +== 2.9 Set count number == 856 + 857 + 858 +Feature: Manually set the count number 859 + 860 +(% style="color:blue" %)**AT Command: AT+SETCNT** 861 + 862 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 863 +|=(% style="width: 160px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 223px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 96px;background-color:#4F81BD;color:white" %)**Response** 864 +|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 865 +|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 866 + 867 +(% style="color:blue" %)**Downlink Command:** 868 + 869 +* **Example**: 0xA6000001 ~/~/ Same as AT+ SETCNT =1 870 + 871 +* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 872 + 873 +== 2.10 Set Transmit Interval Time == 874 + 875 + 876 +((( 877 +Feature: Change NB-IoT End Node Transmit Interval. 878 +))) 879 + 880 +((( 881 +(% style="color:blue" %)**AT Command: AT+TDC** 882 +))) 883 + 884 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 885 +|=(% style="width: 156px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 137px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response** 886 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 887 +30000 888 +OK 889 +the interval is 30000ms = 30s 890 +))) 891 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 892 +OK 893 +Set transmit interval to 60000ms = 60 seconds 894 +))) 895 + 896 +((( 897 +(% style="color:blue" %)**Downlink Command: 0x01** 898 +))) 899 + 900 +((( 901 +Format: Command Code (0x01) followed by 3 bytes time value. 902 +))) 903 + 904 +((( 905 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 906 +))) 907 + 908 +* ((( 909 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 910 +))) 911 +* ((( 912 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 913 +))) 914 + 915 += 3. Configure SW3L-NB = 916 + 490 490 == 3.1 Configure Methods == 491 491 492 492 493 - DDS45-NB supports below configure method:920 +SW3L-NB supports below configure method: 494 494 495 495 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 496 496 ... ... @@ -579,7 +579,7 @@ 579 579 = 4. Battery & Power Consumption = 580 580 581 581 582 - DDS45-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.1009 +SW3L-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 583 583 584 584 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 585 585 ... ... @@ -611,65 +611,56 @@ 611 611 [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]] 612 612 613 613 614 -= =6.2Can I use DDS45-NB in condensationenvironment?==1041 += 7. Order Info = 615 615 616 616 617 - DDS45-NB is notsuitable to beused incondensation environment.Condensation on the DDS45-NBprobe will affect the reading and always got 0.1044 +Part Number: (% style="color:blue" %)**SW3L-NB-XX-YY** 618 618 1046 +(% style="color:red" %)**XX**(%%): 619 619 620 - =7.Trouble Shooting=1048 +* (% style="color:#037691" %)**GE**(%%): General version ( Exclude SIM card) 621 621 622 - ==7.1Whydoesthesensorreadingshow 0 or"Nosensor" ==1050 +* (% style="color:#037691" %)**1D**(%%): with 1NCE* 10 years 500MB SIM card and Pre-configure to DataCake server 623 623 1052 +(% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 624 624 625 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor. 1054 +((( 1055 +(% style="color:blue" %)**YY**(%%): Flow Sensor Model: 1056 +))) 626 626 627 -2. Sensor wiring is disconnected 1058 +((( 1059 + **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1060 +))) 628 628 629 -3. Not using the correct decoder 1062 +((( 1063 + **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1064 +))) 630 630 1066 +((( 1067 + **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1068 +))) 631 631 632 -== 7.2 Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large == 1070 +* ((( 1071 +calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1072 +))) 633 633 1074 +* ((( 1075 +calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1076 +))) 634 634 635 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.) 1078 +* ((( 1079 +calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 636 636 637 -2) Does it change with temperature, temperature will affect its measurement 638 638 639 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode. 1082 + 1083 +))) 640 640 641 - downlink command: (% style="color:blue"%)**F101**(%%), AT command:(% style="color:blue"%)**AT+DDEBUG=1**1085 += 8. Packing Info = 642 642 643 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis 644 644 645 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]] 646 - 647 - 648 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data. 649 - 650 -Please send the data to us for check. 651 - 652 - 653 -= 8. Order Info = 654 - 655 - 656 -Part Number: (% style="color:blue" %)**DDS45-NB-XX** 657 - 658 -(% style="color:red" %)**XX**(%%): 659 - 660 -* (% style="color:#037691" %)**GE**(%%): General version ( Exclude SIM card) 661 - 662 -* (% style="color:#037691" %)**1D**(%%): with 1NCE* 10 years 500MB SIM card and Pre-configure to DataCake server 663 - 664 -(% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 665 - 666 - 667 -= 9. Packing Info = 668 - 669 - 670 670 (% style="color:#037691" %)**Package Includes**: 671 671 672 -* DDS45-NB NB-IoT Distance Detection sensor x 11090 +* SW3L-NB NB-IoT Distance Detection sensor x 1 673 673 674 674 * External antenna x 1 675 675 ... ... @@ -683,7 +683,7 @@ 683 683 684 684 * Weight / pcs : 180g 685 685 686 -= 10. Support =1104 += 9. Support = 687 687 688 688 689 689 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.