Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 6 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -S W3L-NB -- NB-IoTFlowSensor User Manual1 +DS03A-NB -- NB-IoT Door Sensor User Manual - Content
-
... ... @@ -1,13 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20231010 090810-1.png||height="518" width="839"]]2 +[[image:image-20231011093014-5.png]] 3 3 4 4 5 5 6 6 7 - 8 - 9 - 10 - 11 11 **Table of Contents:** 12 12 13 13 {{toc/}} ... ... @@ -19,26 +19,30 @@ 19 19 20 20 = 1. Introduction = 21 21 22 -== 1.1 What is S W3L-NB NB-IoTFlowSensor ==18 +== 1.1 What is DS03A-NB NB-IoT Door Sensor == 23 23 24 24 25 -The Dragino S W3L-NB is aFlowSensor**(%%). It detectswaterflowvolumeand uplink to IoT server via NB-IoT network.User canuse thisto(%style="color:blue"%)**monitorthewaterusageforbuildings**.21 +The Dragino DS03A-NB is a (% style="color:blue" %) **NB-IoT Door Sensor**(%%) for Internet of Things solution. It (% style="color:blue" %)**detects door open/close status**(%%) and uplinks to IoT server via NB-IoT network. user can see the door status, open duration, open counts in the IoT Server. 26 26 27 -The S W3L-NB will sendwaterflow volumeevery 20minutes.It canalsodetect the(%style="color:blue"%)**waterflowstatus and sendAlarm**(%%),to avoidthewaste forwaterusage suchas brokentoiletcase.23 +The DS03A-NB will send periodically data every 2 hours as well as for each door open/close action. It also counts the door open times and calculates the last door open duration. Users can also disable the uplink for each open/close event, instead, DS03A-NB can count each open event and uplink periodically. 28 28 29 -S W3L-NBisdesigned forbothindoor and outdoorse.Ithasa weatherproof enclosure andindustrial levelbatteryto(%style="color:blue"%)**workin low tohigh temperatures**.25 +DS03A-NB supports (% style="color:blue" %)**Datalog Feature,** (%%)it can save the data when there is no NB-IoT network and uplink when network recover. 30 30 31 -S W3L-NB supportsdifferentuplink methods including(% style="color:blue" %)**MQTT,MQTTs,UDP & TCP**(%%)fordifferentapplicationrequirement,andsupportuplinkstovariousIoTServers.27 +DS03A-NB has the (% style="color:blue" %)**Open Alarm Feature**,(%%) user can set this feature so the device will send an alarm if the door has been open for a certain time. 32 32 33 -S W3L-NB(%style="color:blue"%)**supportsBLEconfigure**(%%)and(%style="color:blue"%)** OTA update**(%%)which makeusereasytouse.29 +DS03A-NB is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures 34 34 35 -S W3L-NBisweredby(% style="color:blue" %)**8500mAhLi-SOCI2battery**(%%),it isdesignedfor long-termuseup toseveral years.31 +DS03A-NB supports different uplink methods including (% style="color:blue" %)**MQTT, MQTTs, UDP & TCP**(%%) for different application requirement, and support uplinks to various IoT Servers. 36 36 37 -S W3L-NBhasoptionaluilt-inSIMcardanddefault IoT serverconnectionversion. Which makesit workswithsimpleconfiguration.33 +DS03A-NB (% style="color:blue" %)**supports BLE configure **(%%)and(% style="color:blue" %)** OTA update**(%%) which make user easy to use. 38 38 39 - [[image:image-20231010091546-2.png||height="348"width="909"]]35 +DS03A-NB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long-term use up to several years. 40 40 37 +DS03A-NB has optional built-in SIM card and default IoT server connection version. Which makes it works with simple configuration. 41 41 39 +[[image:image-20231011093807-6.png||height="278" width="879"]] 40 + 41 + 42 42 == 1.2 Features == 43 43 44 44 ... ... @@ -45,7 +45,10 @@ 45 45 * NB-IoT Bands: B1/B2/B3/B4/B5/B8/B12/B13/B17/B18/B19/B20/B25/B28/B66/B70/B85 @H-FDD 46 46 * Ultra-low power consumption 47 47 * Upload water flow volume 48 -* Monitor water waste 48 +* Door Open/Close detect 49 +* Door open/close statistics 50 +* Datalog Feature 51 +* Open Alarm Feature 49 49 * Multiply Sampling and one uplink 50 50 * Support Bluetooth v5.1 remote configure and update firmware 51 51 * Uplink on periodically ... ... @@ -101,35 +101,22 @@ 101 101 (% class="wikigeneratedid" id="H1.4Ratedenvironmentalconditions" %) 102 102 (% style="display:none" %) (%%) 103 103 104 -== 1.4 Flow Sensor Spec == 105 105 108 +== 1.4 Applications == 106 106 107 -((( 108 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 109 -|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Model**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Probe**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Diameter**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Range**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Max Pressure**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Measure** 110 -|(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L 111 -|(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L 112 -|(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L 113 -))) 114 114 111 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654741400370-813.png?rev=1.1||alt="1654741400370-813.png"]] 115 115 116 -== 1.5 Applications == 117 117 114 +== 1.5 Sleep mode and working mode == 118 118 119 -* Flow Sensor application 120 -* Water Control 121 -* Toilet Flow Sensor 122 -* Monitor Waste water 123 123 124 -== 1.6 Sleep mode and working mode == 125 - 126 - 127 127 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any NB-IoT activate. This mode is used for storage and shipping to save battery life. 128 128 129 129 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as NB-IoT Sensor to Join NB-IoT network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode. 130 130 131 131 132 -== 1. 7Button & LEDs ==122 +== 1.6 Button & LEDs == 133 133 134 134 135 135 [[image:Main.User Manual for LoRaWAN End Nodes.D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual.WebHome@1675071855856-879.png]] ... ... @@ -148,10 +148,10 @@ 148 148 ))) 149 149 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means device is in Deep Sleep Mode. 150 150 151 -== 1. 8BLE connection ==141 +== 1.7 BLE connection == 152 152 153 153 154 -S W3L-NB support BLE remote configure and firmware update.144 +DS03A-NB support BLE remote configure and firmware update. 155 155 156 156 157 157 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case: ... ... @@ -163,19 +163,19 @@ 163 163 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode. 164 164 165 165 166 -== 1. 9Pin Definitions & Switch ==156 +== 1.8 Pin Definitions & Switch == 167 167 168 168 169 169 [[image:image-20230819104805-5.png]] 170 170 171 171 172 -=== 1. 9.1 Jumper JP2 ===162 +=== 1.8.1 Jumper JP2 === 173 173 174 174 175 175 Power on Device when put this jumper. 176 176 177 177 178 -=== 1. 9.2 BOOT MODE / SW1 ===168 +=== 1.8.2 BOOT MODE / SW1 === 179 179 180 180 181 181 **1)** (% style="color:blue" %)**ISP**(%%): upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run. ... ... @@ -183,7 +183,7 @@ 183 183 **2)** (% style="color:blue" %)**Flash**(%%): work mode, device starts to work and send out console output for further debug 184 184 185 185 186 -=== 1. 9.3 Reset Button ===176 +=== 1.8.3 Reset Button === 187 187 188 188 189 189 Press to reboot the device. ... ... @@ -191,7 +191,7 @@ 191 191 (% style="display:none" %) 192 192 193 193 194 -== 1. 10Mechanical ==184 +== 1.9 Mechanical == 195 195 196 196 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/WebHome/1675143884058-338.png?rev=1.1||alt="1675143884058-338.png"]] 197 197 ... ... @@ -204,38 +204,35 @@ 204 204 **Probe Mechanical:** 205 205 206 206 207 - (% style="color:blue"%)**DW-004 FlowSensor: diameter: G1/2” / DN15.450pulseL**197 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS03A%20-%20Outdoor%20LoRaWAN%20OpenClose%20Door%20Sensor%20Manual/WebHome/1654741444887-479.png?width=513&height=399&rev=1.1||alt="1654741444887-479.png"]] 208 208 209 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091350-1.png?width=722&height=385&rev=1.1||alt="image-20220519091350-1.png"]] 210 210 211 211 212 - (% style="color:blue"%)**006:DW-006 Flow Sensor: diameter:G3/4” /DN20. 390 pulse =1 L**201 +== 1.10 Magnet Distance == 213 213 214 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-2.png?width=723&height=258&rev=1.1||alt="image-20220519091423-2.png"]] 215 215 204 +* Wood Door: 10mm ~~ 30mm 205 +* Iron Door: 30 ~~ 45mm 216 216 217 -(% style="color:blue" %)**010: DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L** 218 218 219 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519091423-3.png?width=724&height=448&rev=1.1||alt="image-20220519091423-3.png"]] 220 220 209 += 2. Use DS03A-NB to communicate with IoT Server = 221 221 222 -= 2. Use SW3L-NB to communicate with IoT Server = 223 - 224 224 == 2.1 Send data to IoT server via NB-IoT network == 225 225 226 226 227 -The S W3L-NB is equipped with a NB-IoT module, the pre-loaded firmware in SW3L-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by SW3L-NB.214 +The DS03A-NB is equipped with a NB-IoT module, the pre-loaded firmware in DS03A-NB will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by DS03A-NB. 228 228 229 229 230 230 Below shows the network structure: 231 231 232 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/S W3L-NB_NB-IoT_Flow_Sensor_User_Manual/WebHome/image-20231010091546-2.png?width=909&height=348&rev=1.1||alt="image-20231010091546-2.png"]]219 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/DS03A-NB_NB-IoT_Door_Sensor_User_Manual/WebHome/image-20231011093807-6.png?width=879&height=278&rev=1.1||alt="image-20231011093807-6.png"]] 233 233 234 234 235 -There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of S W3L-NB.222 +There are two version: (% style="color:blue" %)**-GE**(%%) and (% style="color:blue" %)**-1D**(%%) version of DS03A-NB. 236 236 237 237 238 -(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set S W3L-NB send data to IoT server.225 +(% style="color:blue" %)**GE Version**(%%): This version doesn't include SIM card or point to any IoT server. User needs to use AT Commands to configure below two steps to set DS03A-NB send data to IoT server. 239 239 240 240 * Install NB-IoT SIM card and configure APN. See instruction of [[Attach Network>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.AttachNetwork]]. 241 241 ... ... @@ -265,13 +265,13 @@ 265 265 [[image:image-20230819113244-11.png||height="141" width="367"]] 266 266 )))|(% style="width:170px" %) 267 267 268 -(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate S W3L-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]].255 +(% style="color:blue" %)**1D Version**(%%): This version has 1NCE SIM card pre-installed and configure to send value to DataCake. User Just need to select the sensor type in DataCake and Activate DS03A-NB and user will be able to see data in DataCake. See here for [[DataCake Config Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H3.4Datacake]]. 269 269 270 270 271 271 == 2.2 Payload Types == 272 272 273 273 274 -To meet different server requirement, S W3L-NB supports different payload type.261 +To meet different server requirement, DS03A-NB supports different payload type. 275 275 276 276 **Includes:** 277 277 ... ... @@ -297,7 +297,7 @@ 297 297 298 298 This is the General Json Format. As below: 299 299 300 -(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"S W3L-NB","distance":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}**287 +(% style="color:#4472c4" %)**{"IMEI":"866207058378443","Model":"DS03A-NB","flow":217,"battery":3.54,"signal":24,"1":{221,2023/09/20 09:47:01},"2":{0,2023/09/20 09:15:04},"3":{0,2023/09/20 09:00:04},"4":{0,2023/09/20 08:45:03},"5":{0,2023/09/20 08:30:03},"6":{0,2023/09/20 08:15:03},"7":{0,2023/09/20 08:00:04},"8":{0,2023/09/20 07:45:04}}** 301 301 302 302 303 303 [[image:image-20230920175015-3.png||height="613" width="890"]] ... ... @@ -307,7 +307,7 @@ 307 307 308 308 * Distance , Battery & Signal are the value at uplink time. 309 309 310 -* Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Distance, Sampling time.297 +* Json entry 1 ~~ 8 are the last 1 ~~ 8 sampling data as specify by (% style="color:#037691" %)**AT+NOUD=8 ** (%%)Command. Each entry includes (from left to right): Water Flow, Sampling time. 311 311 312 312 === 2.2.2 HEX format Payload(Type~=0) === 313 313 ... ... @@ -328,7 +328,7 @@ 328 328 329 329 These bytes include the hardware and software version. 330 330 331 -(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x 0bfor SW3L-NB318 +(% style="color:#037691" %)**Higher byte:**(%%) Specify Sensor Model: 0x12 for DS03A-NB 332 332 333 333 (% style="color:#037691" %)**Lower byte:**(%%) Specify the software version: 0x64=100, means firmware version 1.0.0 334 334 ... ... @@ -355,11 +355,6 @@ 355 355 **99** Not known or not detectable 356 356 357 357 358 -(% style="color:blue" %)**Distance: ** 359 - 360 -Ex1: 0x03a4 = 932 mm 361 - 362 - 363 363 (% style="color:blue" %)**Timestamp: ** 364 364 365 365 Unit Timestamp Example: 650abc40(H) = 1695202368(D) ... ... @@ -372,7 +372,7 @@ 372 372 373 373 Type3 payload special design for ThingsBoard, it will also configure other default server to ThingsBoard. 374 374 375 -(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "S W3L","distance": 502,"battery": 3.57,"signal": 23}**357 +(% style="color:#4472c4" %)** {"IMEI": "866207058378443","Model": "DS03A","flow": 502,"battery": 3.57,"signal": 23}** 376 376 377 377 [[image:image-20230922094043-2.png||height="558" width="851"]] 378 378 ... ... @@ -387,7 +387,7 @@ 387 387 388 388 As below: 389 389 390 -(% style="color:#4472c4" %)**field1= Distancevalue&field2=Battery value&field3=Singal value**372 +(% style="color:#4472c4" %)**field1=Flow value&field2=Battery value&field3=Singal value** 391 391 392 392 [[image:image-20230921104741-1.png||height="565" width="826"]] 393 393 ... ... @@ -394,326 +394,328 @@ 394 394 395 395 == 2.3 Uplink Payload == 396 396 397 -=== 2.3. 1Sensor Configuration, FPORT~=4 ===379 +=== 2.3.2 Sensor Configuration, FPORT~=4 === 398 398 399 399 400 -S W3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server.382 +DS03A-NB will only send this command after getting the downlink command **(0x26 02)** from the server. 401 401 402 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 403 -|(% style="background-color:#4f81bd; color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4f81bd; color:white; width:105px" %)**3**|(% style="background-color:#4f81bd; color:white; width:60px" %)**1**|(% style="background-color:#4f81bd; color:white; width:96px" %)**1**|(% style="background-color:#4f81bd; color:white; width:105px" %)**2**|(% style="background-color:#4f81bd; color:white; width:74px" %)**1** 404 -|**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 384 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 385 +|(% colspan="8" style="background-color:#d9e2f3; color:#0070c0; width:515px" %)**Sensor Configuration FPORT=4** 386 +|**Size(bytes)**|(% style="width:75px" %)**3**|(% style="width:50px" %)**1**|(% style="width:100px" %)**1**|(% style="width:90px" %)**2**|(% style="width:100px" %)**1**|(% style="width:100px" %)**2**|(% style="width:98px" %)**1** 387 +|**Value**|(% style="width:75px" %)TDC (unit:sec)|(% style="width:77px" %)Disalarm|(% style="width:96px" %)((( 388 +Keep status1 389 +)))|(% style="width:99px" %)((( 390 +Keep time1(unit: sec) 391 +)))|(% style="width:87px" %)Keep status2|(% style="width:97px" %)((( 392 +Keep time2(unit: sec) 393 +)))|(% style="width:98px" %)((( 394 +Alarm interval(unit: min) 395 +))) 405 405 406 406 Example parse in TTNv3 407 407 408 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230614172555-4.png?width=853&height=151&rev=1.1||alt="image-20230614172555-4.png"]]399 +[[image:image-20230630155527-3.png||height="146" width="902"]] 409 409 410 410 411 -* (% style="color:blue" %)**TDC: (default: 0x0004B0)** 402 +* ((( 403 +(% style="color:blue" %)**TDC: (default: 0x001C20)** 404 +))) 412 412 413 -Uplink interval for the totalpulsecount, default value is 0x0004B0which is1200 seconds = 20minutes.406 +Uplink interval for the Open/Close Event, default value is 0x001C20 which is 7200 seconds = 2 hours. 414 414 415 415 416 -* (% style="color:blue" %)**STOP Duration & Alarm Timer** 409 +* ((( 410 +(% style="color:blue" %)**Disalarm: (default: 0)** 411 +))) 417 417 418 -S hows theconfigurevalueof[[Alarmfor continuouslywaterflow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]413 + **If Disalarm = 1**, DS03A-NB will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse. 419 419 415 + **If Disalarm = 0**, DS03A-NB will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time. 420 420 421 -=== 2.3.2 Water Flow Value, Uplink FPORT~=2 === 422 422 418 +(% style="color:red" %)** Note: When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast. ** 423 423 424 -((( 425 -SW3L-NB will send this uplink **after** Device Status once join the NB-IoT network successfully. And SW3L-NB will: 426 -))) 427 427 428 -((( 429 - periodicallysendthisuplinkevery20 minutes,thisinterval [[can bechanged>>||anchor="H2.10SetTransmitIntervalTime"]].421 +* ((( 422 +(% style="color:blue" %)**Keep Status1 & Keep Time1 & Keep Status2 & Keep Time2** 430 430 ))) 431 431 432 -((( 433 -Uplink Payload totals 11 bytes. 425 +Shows the configure value of [[Alarm Base on Timeout Feature>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 426 + 427 + 428 + 429 +* ((( 430 +(% style="color:blue" %)**Alarm interval(default: 0)** 434 434 ))) 435 435 436 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 437 -|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value, FPORT=2** 438 -|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 439 -|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 440 -Total pulse Or Last Pulse 441 -)))|(% style="width:78px" %)((( 442 -MOD & PA4_status & PB15_status 443 -)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)Unix TimeStamp 433 +When the state of the door sensor has not been changed after the timeout alarm, the device will send a uplink every alarm interval. It will stop the alarm until the state of the door sensor is changed after the timeout alarm. 444 444 445 -**Calculate Flag & Alarm:** 446 446 447 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 448 -|(% style="background-color:#4f81bd; color:white; width:70px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:70px" %)**[bit7:bit6]**|(% style="background-color:#4f81bd; color:white; width:90px" %)**[bit5:bit2]**|(% style="background-color:#4f81bd; color:white; width:140px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:130px" %)**bit0** 449 -|(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes 436 +=== 2.3.3 Real-Time Open/Close Status, Uplink FPORT~=2 === 450 450 451 -**MOD & PA4_status & PB15_status:** 452 452 453 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %) 454 -|(% style="background-color:#4f81bd; color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:60px" %)**[bit5:bit0]** 455 -|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 439 +DS03A-NB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And DS03A-NB will send uplinks when: 456 456 457 -(% style="color:#037691" %)** **[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230626093242-1.png?width=892&height=276&rev=1.1||alt="image-20230626093242-1.png"]] 441 +* Every 2 hours, this interval [[can be changed>>||anchor="H3.3.1A0SetTransmitIntervalTime"]]. 442 +* There is an Open/Close event. (This info can be disabled by AT+DISALARM=1) 458 458 444 +**1) When (% style="color:blue" %)AT+TTRCHANNEL=1(%%), Uplink Payload totals (% style="color:blue" %)11 bytes. (Default mode)(%%)** 459 459 460 -* ((( 461 -(% style="color:blue" %)**Calculate Flag** 462 -))) 446 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 447 +|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0;width:515px" %)**Real-Time Open/Close Status, FPORT=2** 448 +|(% style="width:94px" %)**Size(bytes)**|(% style="width:97px" %)**1**|(% style="width:95px" %)**3**|(% style="width:119px" %)**3**|(% style="width:107px" %)**4** 449 +|(% style="width:95px" %)**Value**|(% style="width:97px" %)((( 450 +Status & [[Alarm>>||anchor="H3.3.4A0TTRIG126TTRIG2timeoutstatusalarm"]] 451 +)))|(% style="width:95px" %)Total open door events|(% style="width:119px" %)((( 452 +The last door open duration (unit: sec) 453 +)))|(% style="width:108px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 463 463 464 -((( 465 -The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse. 466 -))) 455 +**Status & Alarm:** 467 467 468 -((( 469 -**Example: in the default payload:** 457 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 458 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:120px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**bit0** 459 +|(% style="width:76px" %)**Value**|(% style="width:96px" %)Reserve|(% style="width:110px" %)((( 460 +Count mod 461 +)))|(% style="width:106px" %)TDC flag 0:No;1:Yes|(% style="width:148px" %)((( 462 +Alarm 0: No Alarm; 1: Alarm 463 +)))|(% style="width:131px" %)((( 464 +Status 0: Close; 1: Open 470 470 ))) 471 471 467 +[[image:image-20230630155451-2.png||height="246" width="928"]] 468 + 469 + 472 472 * ((( 473 - calculateflag=0: for SW3L-004 Flow Sensor:450pulse=1 L471 +(% style="color:blue" %)**Count mod:Default=0** 474 474 ))) 473 + 474 +0: Uplink total open door times since factory 475 + 476 +1: Uplink total open door times since last FPORT=2 uplink. 477 + 478 + 479 +* (% style="color:blue" %)**TDC flag** 480 + 481 +When the flag is 1, it means sending packets at normal time intervals. 482 + 483 +Otherwise, it is a packet sent at non-TDC time. 484 + 485 + 475 475 * ((( 476 - calculateflag=1: for SW3L-006 Flow Sensor:390pulse = 1 L487 +(% style="color:#0000ff" %)**Alarm** 477 477 ))) 489 + 490 +See [[Alarm Base on Timeout>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 491 + 492 + 478 478 * ((( 479 - calculateflag=2: for SW3L-010 Flow Sensor:64 pulse= 1 L494 +(% style="color:blue" %)**Status** 480 480 ))) 481 481 482 -((( 483 -Default value: 0. 497 +This bit is 1 when the door sensor is open and 0 when it is close. 498 + 499 + 500 +* ((( 501 +(% style="color:blue" %)**Total open door events** 484 484 ))) 485 485 486 -((( 487 -Range (4 bits): (b)0000 ~~ (b) 1111 504 +Total pulse/counting base on open door. 488 488 489 - If userusewith a meterforexample is0.02L/pulse.Toproperdecodethe correct valuein server,506 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 490 490 491 -1) User can set the Calculate Flag of this sensor to 3. 492 492 493 -2) In server side, when a sensor data arrive, the decoder will check the value of Calculate Flag, It the value is 3, the total volume = 0.02 x Pulse Count. 509 +* ((( 510 +(% style="color:blue" %)**The last door open duration** 494 494 ))) 495 495 496 -((( 497 -(% style="color:red" %)**NOTE: User need to set Calculate Flag to proper value before use Flow Sensor. Downlink or AT Command see: **(%%)Refer: [[Set Calculate Flag>>||anchor="H2.8Setthecalculateflag"]] 513 +Door sensor last open duration. 498 498 499 -((( 500 - 501 -))) 502 -))) 515 +Unit: sec. 503 503 517 +[[image:image-20230701094042-1.png||height="154" width="763"]] 504 504 505 -* ((( 506 -(% style="color:blue" %)**Alarm** 507 -))) 508 508 509 -((( 510 -See [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]] 511 -))) 520 +**2) When (% style="color:blue" %)AT+TTRCHANNEL=2(%%), Uplink Payload totals (% style="color:blue" %)18 bytes(%%)**(% style="color:blue" %). 512 512 513 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]522 +(When the maximum DR of some frequencies is 11 bytes, it will cause the server to receive empty packets) 514 514 524 +(% style="color:red" %)**Note:When using the AT+TTRCHANNEL=2 command, the Datalog function cannot be used.** 515 515 516 -((( 517 -* (% style="color:blue" %)**TDC flag** 526 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 527 +|=(% colspan="8" style="background-color:#D9E2F3;color:#0070C0; width: 515px;" %)**Real-Time Open/Close Status, FPORT=2** 528 +|(% style="width:50px" %)**Size(bytes)**|(% style="width:97px" %)**1**|(% style="width:95px" %)**3**|(% style="width:125px" %)**3**|(% style="width:100px" %)**4**|(% style="width:86px" %)**1**|(% style="width:96px" %)**3**|(% style="width:126px" %)**3** 529 +|(% style="width:95px" %)**Value**|(% style="width:97px" %)((( 530 +Status1 & Alarm1 531 +)))|(% style="width:95px" %)Total open door events1|(% style="width:125px" %)((( 532 +The last door open duration1 (unit: sec) 533 +)))|(% style="width:100px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]]|(% style="width:86px" %)((( 534 +Status2 & Alarm2 535 +)))|(% style="width:96px" %)Total open door events2|(% style="width:126px" %)The last door open duration2 (unit: sec) 518 518 519 - Whenthe flag is,itmeans sending packets at normal time intervals.537 +**Status1 & Alarm1:** 520 520 521 -Otherwise, it is a packet sent at non-TDC time. 539 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:514px" %) 540 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:100px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:117px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:117px" %)**bit0** 541 +|(% style="width:76px" %)**Value**|(% style="width:96px" %)Reserve|(% style="width:99px" %)((( 542 +Count mod 543 +)))|(% style="width:103px" %)TDC flag 0:No;1:Yes|(% style="width:216px" %)((( 544 +Alarm1 0: No Alarm; 1: Alarm (PA8 of pin) 545 +)))|(% style="width:181px" %)((( 546 +Status1 0: Close; 1: Open (PA8 of pin) 522 522 ))) 523 523 524 -* ((( 525 -(% style="color:blue" %)**Total pulse** 526 -))) 549 +**Status2 & Alarm2:** 527 527 528 -((( 529 -Total pulse/counting since factory 551 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 552 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit7:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:200px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:200px" %)**bit0** 553 +|(% style="width:76px" %)**Value**|(% style="width:113px" %)Reserve|(% style="width:219px" %)((( 554 +Alarm2 0: No Alarm; 1: Alarm (PA4 of pin) 555 +)))|(% style="width:181px" %)((( 556 +Status2 0: Close; 1: Open (PA4 of pin) 530 530 ))) 531 531 532 -((( 533 -Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 559 +[[image:image-20230630155908-6.png||height="295" width="927"]] 534 534 535 - 536 -))) 537 537 538 538 * ((( 539 -(% style="color:blue" %)** LastPulse**563 +(% style="color:blue" %)**Count mod:Default=0** 540 540 ))) 541 541 542 -((( 543 -Total pulse since last FPORT=2 uplink. (Default 20 minutes) 544 -))) 566 +0: Uplink total open door times since factory 545 545 546 -((( 547 -Range (4 Bytes) : 0x00000000~~ 0xFFFFFFFF . 568 +1: Uplink total open door times since last FPORT=2 uplink. 548 548 549 549 550 -* ((( 551 -(% style="color:blue" %)**PA4_status: Support digital level input below 3.3V** 552 -))) 571 +* (% style="color:blue" %)**TDC flag** 553 553 554 -((( 555 -0 ~-~-> PA4 is at low level. 556 -))) 573 +When the flag is 1, it means sending packets at normal time intervals. 557 557 558 -((( 559 -1 ~-~-> PA4 is at high level. 575 +Otherwise, it is a packet sent at non-TDC time. 560 560 561 561 562 562 * ((( 563 -(% style="color: blue" %)**PB15_status: Supportdigital level input below3.3V**579 +(% style="color:#0000ff" %)**Alarm1 or Alarm2** 564 564 ))) 565 565 566 -((( 567 -0 ~-~-> PB15 is at low level. 568 -))) 582 +See [[Alarm Base on Timeout>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 569 569 570 -((( 571 -1 ~-~-> PB15 is at high level.. 572 -))) 573 -))) 574 -))) 575 575 576 576 * ((( 577 -(% style="color:blue" %)** MOD: Default =0**586 +(% style="color:blue" %)**Status1 **(% style="color:#0000ff" %)**or **(% style="color:blue" %)**Status2** 578 578 ))) 579 579 580 -((( 581 -MOD=0 ~-~-> Uplink Total Pulse since factory 582 -))) 589 +This bit is 1 when the door sensor is open and 0 when it is close. 583 583 584 -((( 585 -MOD=1 ~-~-> Uplink total pulse since last FPORT=2 uplink. 586 586 587 - 588 -))) 589 - 590 590 * ((( 591 -(% style="color:blue" %)** WaterFlowValue**593 +(% style="color:blue" %)**Total open door events1 **(% style="color:#0000ff" %)**or**(% style="color:blue" %)** Total open door events2** 592 592 ))) 593 593 594 -((( 595 -**Total Water Flow Volume = (Calculate Flag) x (Total Pulse)=9597/450=21.3L** 596 -))) 596 +Total pulse/counting base on open door. 597 597 598 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-5.png?width=727&height=50&rev=1.1||alt="image-20220519095946-5.png"]]598 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 599 599 600 600 601 -((( 602 -**T otalWaterFlow forTDCtimer=(CalculateFlag)x (LastPulse)=79/450=0.2L**601 +* ((( 602 +(% style="color:blue" %)**The last door open duration1 **(% style="color:#0000ff" %)**or**(% style="color:blue" %)** The last door open duration2** 603 603 ))) 604 604 605 - [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-6.png?width=733&height=43&rev=1.1||alt="image-20220519095946-6.png"]] ** **605 +Door sensor last open duration. 606 606 607 +Unit: sec. 607 607 608 - ===2.3.3 HistoricalWater FlowStatus, FPORT~=3===609 +[[image:image-20230701094042-1.png||height="154" width="763"]] 609 609 610 610 611 -((( 612 -SW3L-NB stores sensor values and users can retrieve these history values via the downlink command. 613 -))) 612 +=== 2.3.4 Historical Door Open/Close Event, FPORT~=3 === 614 614 615 -((( 616 -The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status. 617 617 618 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 619 -|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value, FPORT=3** 620 -|(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4** 621 -|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)((( 622 -Total pulse Or Last Pulse 623 -)))|(% style="width:78px" %)((( 624 -MOD & PA4_status & PB15_status 625 -)))|(% style="width:92px" %)Reserve(0x01)|(% style="width:134px" %)Unix TimeStamp 615 +DS03A-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]]. 626 626 627 - **CalculateFlag&Alarm:**617 +The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time open/close status. 628 628 629 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 630 -|(% style="background-color:#4f81bd; color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:89px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:89px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:69px" %)**[bit5:bit2]**|(% style="background-color:#4f81bd; color:white; width:129px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:89px" %)**bit0** 631 -|(% style="width:88px" %)**Value**|(% style="width:96px" %)((( 632 -No ACK message 633 -)))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes 619 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 620 +|=(% colspan="5" style="background-color:#D9E2F3;color:#0070C0;width:515px" %)**Real-Time Open/Close Status, FPORT=3** 621 +|(% style="width:60px" %)**Size(bytes)**|(% style="width:80px" %)**1**|(% style="width:120px" %)**3**|(% style="width:150px" %)**3**|(% style="width:90px" %)**4** 622 +|(% style="width:95px" %)**Value**|(% style="width:97px" %)((( 623 +Status & [[Alarm>>||anchor="H3.3.3A0AlarmBaseonTimeout"]] 624 +)))|(% style="width:95px" %)Total open door events|(% style="width:119px" %)((( 625 +The last door open duration (unit: sec) 626 +)))|(% style="width:108px" %)[[Unix TimeStamp>>||anchor="H2.5.2UnixTimeStamp"]] 634 634 635 -** MOD & PA4_status &PB15_status:**628 +**Status & Alarm:** 636 636 637 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %) 638 -|(% style="background-color:#4f81bd; color:white; width:60px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:60px" %)**[bit5:bit0]** 639 -|(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD 630 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 631 +|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:65px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**[bit5:bit4]**|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**bit3**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**bit2**|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:75px" %)**bit0** 632 +|(% style="width:76px" %)**Value**|(% style="width:88px" %)No ACK message|(% style="width:92px" %)Poll Message Flag|(% style="width:89px" %)Reserve|(% style="width:90px" %)((( 633 +Count mod 634 +)))|(% style="width:95px" %)((( 635 +TDC flag 0:No; 1:Yes 636 +)))|(% style="width:116px" %)((( 637 +Alarm 0: No Alarm; 1: Alarm 638 +)))|(% style="width:112px" %)((( 639 +Status 0:Close; 1: Open 640 640 ))) 641 641 642 642 * ((( 643 -Each data entry is 11 bytes and has the same structure as [[ realtimewater flowstatus>>||anchor="H2.3.2A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3Lwill send max bytes according to the current DR and Frequency bands.643 +Each data entry is 11 bytes and has the same structure as [[Real-Time open/close status>>||anchor="H2.3.3A0Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2"]], to save airtime and battery, DS03A-NB will send max bytes according to the current DR and Frequency bands. 644 644 ))) 645 645 646 -((( 647 647 For example, in the US915 band, the max payload for different DR is: 648 -))) 649 649 650 650 ((( 651 - (% style="color:blue" %)**a)DR0:**(%%)max is 11 bytes so one entry of data649 +**~1. DR0**: max is 11 bytes so one entry of data 652 652 ))) 653 653 654 654 ((( 655 - (% style="color:blue" %)**b)DR1:**(%%)max is 53 bytes so devices will upload 4 entries of data (total 44 bytes)653 +**2. DR1**: max is 53 bytes so devices will upload 4 entries of data (total 44 bytes) 656 656 ))) 657 657 658 658 ((( 659 - (% style="color:blue" %)**c)DR2:**(%%)total payload includes 11 entries of data657 +**3. DR2**: total payload includes 11 entries of data 660 660 ))) 661 661 662 662 ((( 663 - (% style="color:blue" %)**d)DR3:**(%%)total payload includes 22 entries of data.661 +**4. DR3**: total payload includes 22 entries of data. 664 664 ))) 665 665 666 -((( 667 -If SW3L-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0 664 +If DS03A-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0 668 668 669 - 670 -))) 666 +[[image:image-20230630155556-4.png||height="146" width="938"]] 671 671 672 -((( 673 -(% style="color:#037691" %)**Downlink:** 674 -))) 668 +**Downlink:** 675 675 676 -((( 677 -0x31 64 92 C5 AC 64 92 C7 8C 05 678 -))) 670 +0x31 64 9E 7D 34 64 9E 7E 9C 05 679 679 680 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230626093440-2.png?width=890&height=160&rev=1.1||alt="image-20230626093440-2.png"]] 681 681 673 +**Uplink:** 682 682 683 -((( 684 -(% style="color:#037691" %)**Uplink:** 685 -))) 675 +45 00 00 00 00 00 00 64 9E 7D 48 40 00 00 00 00 00 63 64 9E 7D 9C 41 00 00 01 00 00 63 64 9E 7D A4 40 00 00 01 00 00 8D 64 9E 7E 31 43 00 00 02 00 00 8D 64 9E 7E 44 48 00 00 02 00 00 1F 64 9E 7E 59 4B 00 00 03 00 00 1F 64 9E 7E 6B 686 686 687 -((( 688 -41 00 01 00 00 00 08 64 92 C5 E4 40 00 01 00 00 00 08 64 92 C6 06 49 41 01 00 00 00 00 64 92 C6 8B 49 81 01 00 00 00 00 64 92 C7 34 4A 01 01 00 00 00 2D 64 92 C7 7C 689 689 690 - 691 -))) 678 +**Parsed Value:** 692 692 693 -((( 694 -(% style="color:#037691" %)**Parsed Value:** 695 -))) 680 +[COUNTMOD, TDC_FLAG, ALARM, DOOR_STATUS, OPEN_DOOR_TIMES, LAST_DOOR_OPEN_DURATION, TIME] 696 696 697 -((( 698 -[TDC_flag, Alarm, Calculate Flag, PA4_status, PB15_status, MOD, Total pulse or Last Pulse,** **Water Flow Value, TIME] 699 -))) 700 700 683 +[SUM,YES,FALSE,OPEN,0,0,2023-06-30 06:59:20], 701 701 702 -((( 703 -[YES,FALSE,0,L,L, 0,8, 0.0,2023-06-21 09:41:56], 685 +[SUM,NO,FALSE,CLOSE,0,99,2023-06-30 07:00:44], 704 704 705 -[NO,FALSE, 0,L,L,0,8,0.0,2023-06-2109:42:30],687 +[SUM,NO,FALSE,OPEN, 1,99,2023-06-30 07:00:52], 706 706 707 -[ YES,FALSE,2,L,H,1,0, 0.0,2023-06-2109:44:43],689 +[SUM,NO,FALSE,CLOSE,1,141,2023-06-30 07:03:13], 708 708 709 -[ YES,FALSE,2,H,L,1,0, 0.0,2023-06-2109:47:32],691 +[SUM,NO,TRUE,OPEN, 2,141,2023-06-30 07:03:32], 710 710 711 -[NO,TRUE ,2, L,L,1,45,0.7,2023-06-21 09:48:44], 712 -))) 693 +[PART,NO,FALSE,CLOSE,2,31,2023-06-30 07:03:53], 713 713 714 -[ [image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L-LB_LoRaWAN_Flow_Sensor_User_Manual/WebHome/image-20230626093703-3.png?width=894&height=156&rev=1.1||alt="image-20230626093703-3.png"]]695 +[PART,NO,TRUE,OPEN, 3,31,2023-06-30 07:04:11], 715 715 697 +[[image:image-20230630172740-1.png||height="199" width="868"]] 716 716 699 + 700 + 717 717 == 2.4 Test Uplink and Change Update Interval == 718 718 719 719 ... ... @@ -729,7 +729,7 @@ 729 729 == 2.5 Multi-Samplings and One uplink == 730 730 731 731 732 -To save battery life, S W3L-NB will sampleDistance data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by:716 +To save battery life, DS03A-NB will sample Water Flow data every 15 minutes and send one uplink every 2 hours. So each uplink it will include 8 stored data + 1 real-time data. They are defined by: 733 733 734 734 * (% style="color:#037691" %)**AT+TR=900** (%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds (15 minutes, the minimum can be set to 180 seconds) 735 735 ... ... @@ -743,7 +743,7 @@ 743 743 == 2.6 Trggier an uplink by external interrupt == 744 744 745 745 746 -S W3L-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets.730 +DS03A-NB has an external trigger interrupt function. Users can use the PB15 pin to trigger the upload of data packets. 747 747 748 748 (% style="color:blue" %)**AT command:** 749 749 ... ... @@ -757,164 +757,333 @@ 757 757 758 758 * (% style="color:#037691" %)**AT+INTMOD=3 **(%%) ~/~/ Trigger by rising edge 759 759 760 -== 2.7 Alarm for continuously water flow == 761 761 762 762 763 -((( 764 -This feature is to monitor and send Alarm for continuously water flow. 765 -))) 746 +== 2.7 Set Transmit Interval Time == 766 766 767 -((( 768 -Example case is for Toilet water monitoring, if some one push toilet button, the toilet will have water flow. If the toilet button has broken and can't returned to original state, the water flow will keep for hours or days which cause huge waste for water. 769 -))) 770 770 771 771 ((( 772 - To monitorthis faultyandsendalarm,thereare two settings:750 +Feature: Change NB-IoT End Node Transmit Interval. 773 773 ))) 774 774 775 -* ((( 776 -(% style="color:blue" %)**Stop Duration: Unit: Second** 777 -))) 778 - 779 779 ((( 780 - Default:15s, If SW3L-NB didn'tsee anywater flow in 15s, SW3L-NB will considerstopof water flow event.754 +(% style="color:blue" %)**AT Command: AT+TDC** 781 781 ))) 782 782 783 -* ((( 784 -(% style="color:blue" %)**Alarm Timer: Units: Minute; Default 0 minutes (means Alarm disable)** 757 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 758 +|=(% style="width: 156px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 137px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response** 759 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 760 +30000 761 +OK 762 +the interval is 30000ms = 30s 785 785 ))) 786 - 787 - (((788 - **Example:** 3 minutes, ifSW3L-NB detecta start of water flow eventand didn'tdetectastopevent within Alarmtimer,SW3L-NBwillsend an Alarm to indicate a water flow abnormal alarm.764 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 765 +OK 766 +Set transmit interval to 60000ms = 60 seconds 789 789 ))) 790 790 791 791 ((( 792 - Sofor example, If wesetstop duration=15s and Alarm Timer=3minutes. If the toilet water flowcontinuously formore than 3 minutes,Sensorwill send an alarm (in ConfirmedMODE) to platform.770 +(% style="color:blue" %)**Downlink Command: 0x01** 793 793 ))) 794 794 795 795 ((( 796 - (% style="color:red" %)**Note:** **Afterthis alarmis send,sensor will considerastop ofwater flowandcountforanother new event. So if water flow wastelastfor 1 hour, Sensor will keepsendingalarm every 3 minutes.**774 +Format: Command Code (0x01) followed by 3 bytes time value. 797 797 ))) 798 798 799 799 ((( 800 - (%style="color:blue"%)**ATCommandtoconfigure:**778 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 801 801 ))) 802 802 803 803 * ((( 804 - AT+PTRIG=15,3~-~->SetStop duration: 15s, AlarmTimer:3minutes.782 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 805 805 ))) 784 +* ((( 785 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 786 +))) 806 806 788 + 789 +=== 3.3.3 Enable / Disable Alarm === 790 + 791 + 792 +Feature: Enable/Disable Alarm for open/close event. Default value 0. 793 + 794 +(% style="color:blue" %)**AT Command: ** 795 + 796 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 797 +|(% style="background-color:#d9e2f3; color:#0070c0; width:153px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:276px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0; width:86px" %)**Response** 798 +|(% style="width:154px" %)AT+DISALARM=1|(% style="width:278px" %)End node will only send packets in TDC time.|OK 799 +|(% style="width:154px" %)AT+DISALARM=0|(% style="width:278px" %)End node will send packets in TDC time or status change for door sensor|OK 800 + 801 +(% style="color:blue" %)**Downlink Command: ** 802 + 803 +0xA7 01 ~/~/ Same As AT+DISALARM=1 804 + 805 +0xA7 00 ~/~/ Same As AT+DISALARM=0 806 + 807 + 808 +=== 3.3.4 Alarm Base on Timeout === 809 + 810 + 811 +DS03A-LB can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 812 + 807 807 * ((( 808 - AT+PTRIG=15,0 ~-~-> Default Value,disablewaterwasteAlarm.814 +(% style="color:blue" %)**Keep Status: Status to be monitor** 809 809 ))) 810 810 811 -((( 812 -(% style="color:blue" %)**Downlink Command to configure:** 817 +(% style="color:#037691" %)**Keep Status = 1**(%%): Monitor Close to Open event 818 + 819 +(% style="color:#037691" %)**Keep Status = 0**(%%): Monitor Open to Close event 820 + 821 + 822 +* ((( 823 +(% style="color:blue" %)**Keep Time: Timeout to send an Alarm** 813 813 ))) 814 814 815 -((( 816 -Command: **0xAA aa bb cc** 826 +Range 0 ~~ 65535(0xFFFF) seconds. 827 + 828 +If (% style="color:#037691" %)**keep time = 0**(%%), Disable Alarm Base on Timeout feature. 829 + 830 +If (% style="color:#037691" %)**keep time > 0**(%%), device will monitor the keep status event and send an alarm when status doesn't change after timeout. 831 + 832 + 833 +* ((( 834 +(% style="color:blue" %)**Downlink Command** 817 817 ))) 818 818 819 -((( 820 -AA: Command Type Code 837 +(% style="color:#037691" %)**Command: 0xA9 aa bb cc dd** 838 + 839 +**A9:** Command Type Code 840 + 841 +**aa: **01:TTRIG1; 02:TTRIG2 842 + 843 +**bb:** status to be monitored 844 + 845 +**cc dd:** timeout. 846 + 847 + 848 +**1) AT+TTRIG1 : (PA8 of pin)** 849 + 850 +(% style="color:blue" %)**AT Command to configure:** 851 + 852 +* ((( 853 +(% style="color:#037691" %)**AT+TTRIG1=1,30** (%%) **~-~->** When the **Keep Status** change from close to open, and device remains in open status for more than 30 seconds. DS03A-LB will send an uplink packet, the Alarm1 bit(the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 854 + 855 +(% style="color:#037691" %)**AT+TTRIG1=0,30** (%%) **~-~->** When the **Keep Status** change from open to close, and device remains in open status for more than 30 seconds. DS03A-LB will send an uplink packet, the Alarm1 bit (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1. 821 821 ))) 822 822 823 -((( 824 -aa: Stop duration 858 +* ((( 859 +(% style="color:#037691" %)**AT+TTRIG1=0,0** (%%) **~-~-> ** Default Value, disable timeout Alarm. 860 + 861 + 862 + 825 825 ))) 826 826 827 -((( 828 -bb cc: Alarm Timer 865 +(% style="color:blue" %)**Downlink Command to configure:** 866 + 867 +If user send 0xA9 01 01 00 1E: equal to AT+TTRIG1=1,30 **or** 0xA9 01 00 00 00: Equal to AT+TTRIG1=0,0. 868 + 869 + 870 +**2) AT+TTRIG2 : (PA4 of pin,need to use AT+TTRCHANNEL=2)** 871 + 872 +(% style="color:blue" %)**AT Command to configure:** 873 + 874 +* ((( 875 +(% style="color:#037691" %)**AT+TTRIG2=1,30** (%%) **~-~->** When the **Keep Status** change from close to open, and device remains in open status for more than 30 seconds. DS03A-LB will send an uplink packet, the Alarm2 bit (the second bit of 12^^st^^ byte of payload) on this uplink packet is set to 1. 876 + 877 +(% style="color:#037691" %)**AT+TTRIG2=0,30** (%%) **~-~->** When the **Keep Status** change from open to close, and device remains in open status for more than 30 seconds. DS03A-LB will send an uplink packet, the Alarm2 bit (the second bit of 12^^st^^ byte of payload) on this uplink packet is set to 1. 829 829 ))) 830 830 831 -((( 832 -If user send 0xAA 0F 00 03: equal to AT+PTRIG=15,3 880 +* ((( 881 +(% style="color:#037691" %)**AT+TTRIG2=0,0** (%%) **~-~-> ** Default Value, disable timeout Alarm. 882 + 883 + 884 + 833 833 ))) 834 834 887 +(% style="color:blue" %)**Downlink Command to configure:** 835 835 836 - ==2.8 Setthecalculateflag==889 +If user send 0xA9 02 00 00 1E: equal to AT+TTRIG2=0,30 **or** 0xA9 02 00 00 00: Equal to AT+TTRIG2=0,0. 837 837 838 838 839 - Feature:Setthecalculateflag892 +=== 3.3.5 TTRIG1 & TTRIG2 timeout status alarm === 840 840 841 -(% style="color:blue" %)**AT Command: AT+CALCFLAG** 842 842 843 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %) 844 -|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 193px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Response** 845 -|(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK 846 -|(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK 895 +It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval. 847 847 897 +(% style="color:blue" %)**AT Command:** 898 + 899 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 900 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 279px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 76px;background-color:#D9E2F3;color:#0070C0" %)**Response** 901 +|(% style="width:155px" %)((( 902 +AT+TTRALARM=0 903 +)))|(% style="width:279px" %)((( 904 +disable continuous alarm 905 +)))|(% style="width:84px" %)((( 906 +OK 907 +))) 908 +|(% style="width:155px" %)((( 909 +AT+TTRALARM=60 910 +)))|(% style="width:279px" %)((( 911 +The alarm interval is 60 minutes (unit: minutes) 912 +)))|(% style="width:84px" %)((( 913 +OK 914 +))) 915 + 848 848 (% style="color:blue" %)**Downlink Command:** 849 849 850 - * **Example**: 0XA501~/~/ SameasAT+CALCFLAG=1918 +Example: 0C aa => AT+TTRALARM= aa 851 851 852 -== 2.9 Set count number == 853 853 921 +=== 3.3.6 Count Mod === 854 854 855 -Feature: Manually set the count number 856 856 857 - (% style="color:blue"%)**ATCommand:AT+SETCNT**924 +Feature: Manually set the count mode. 858 858 859 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %) 860 -|=(% style="width: 160px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 223px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 96px;background-color:#4F81BD;color:white" %)**Response** 861 -|(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK 862 -|(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK 926 +(% style="color:blue" %)**AT Command:** 863 863 928 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %) 929 +|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 275px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 86px;background-color:#D9E2F3;color:#0070C0" %)**Response** 930 +|(% style="width:155px" %)((( 931 +AT+COUNTMOD=0 932 +)))|(% style="width:277px" %)((( 933 +the count value keeps accumulating mode 934 +)))|(% style="width:86px" %)((( 935 +OK 936 +))) 937 +|(% style="width:155px" %)((( 938 +AT+COUNTMOD=1 939 +)))|(% style="width:277px" %)((( 940 +the count value will be reset after each TDC time(Last Close Duration Reset after each uplink) 941 +)))|(% style="width:86px" %)((( 942 +OK 943 +))) 944 + 864 864 (% style="color:blue" %)**Downlink Command:** 865 865 866 - * **Example**: 0xA6000001~/~/ SameasAT+SETCNT =1947 +Example: 0B aa => AT+COUNTMOD = second byte 867 867 868 -* **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 869 869 870 -== 2.10Set Transmit IntervalTime ==950 +=== 3.3.7 Number of channel of door sensors === 871 871 872 872 873 -((( 874 -Feature: Change NB-IoT End Node Transmit Interval. 875 -))) 953 +Feature: Set the number of door sensor channels. 876 876 877 -((( 878 -(% style="color:blue" %)**AT Command: AT+TDC** 879 -))) 955 +(% style="color:blue" %)**AT Command:** 880 880 881 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 882 -|=(% style="width: 156px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 137px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response** 883 -|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 884 -30000 957 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 958 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 959 +|(% style="width:155px" %)((( 960 +AT+TTRCHANNEL=1 961 +)))|(% style="width:259px" %)((( 962 +Set as single channel, only use PA8 pin as interrupt pin. 963 +)))|(% style="width:44px" %)((( 885 885 OK 886 -the interval is 30000ms = 30s 887 887 ))) 888 -|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 966 +|(% style="width:155px" %)((( 967 +AT+TTRCHANNEL=2 968 +)))|(% style="width:259px" %)((( 969 +Set as dual channel, use PA8 pin and PA4 pin as interrupt pin. 970 +)))|(% style="width:44px" %)((( 889 889 OK 890 -Set transmit interval to 60000ms = 60 seconds 891 891 ))) 892 892 893 -((( 894 -(% style="color:blue" %)**Downlink Command: 0x01** 895 -))) 974 +(% style="color:blue" %)**Downlink Command:** 896 896 897 -((( 898 -Format: Command Code (0x01) followed by 3 bytes time value. 976 +Example: 0D aa => AT+TTRCHANNEL = second byte 977 + 978 + 979 +=== 3.3.8 Set Time Sync Mode === 980 + 981 + 982 +Feature: Enable/Disable Sync system time via LoRaWAN MAC Command (DeviceTimeReq), LoRaWAN server must support v1.0.3 protocol to reply to this command. 983 + 984 +SYNCMOD is set to 1 by default. If user wants to set a different time from the LoRaWAN server, the user needs to set this to 0. 985 + 986 +(% style="color:blue" %)**AT Command:** 987 + 988 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 989 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 990 +|(% style="width:155px" %)((( 991 +AT+SYNCMOD=1 992 +)))|(% style="width:259px" %)((( 993 +Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq) The default is zero time zone. 994 +)))|(% style="width:44px" %)((( 995 +OK 899 899 ))) 997 +|(% style="width:155px" %)((( 998 +AT+SYNCMOD=1,8 999 +)))|(% style="width:259px" %)((( 1000 +Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq) Set to East eight time zone. 1001 +)))|(% style="width:44px" %)((( 1002 +OK 1003 +))) 1004 +|(% style="width:155px" %)AT+SYNCMOD=1,-12|(% style="width:259px" %)Enable Sync system time via LoRaWAN MAC Command (DeviceTimeReq) Set to West Twelve Time Zone.|(% style="width:44px" %)OK 900 900 901 -((( 902 -If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 1006 +(% style="color:blue" %)**Downlink Command:** 1007 + 1008 +0x28 01 ~/~/ Same As AT+SYNCMOD=1 1009 + 1010 +0x28 01 08 ~/~/ Same As AT+SYNCMOD=1,8 1011 + 1012 +0x28 01 F4 ~/~/ Same As AT+SYNCMOD=1,-12 1013 + 1014 +0x28 00 ~/~/ Same As AT+SYNCMOD=0 1015 + 1016 + 1017 +=== 3.3.9 Clear the open door times and the duration of the last open door === 1018 + 1019 + 1020 +(% style="color:blue" %)**AT Command:** 1021 + 1022 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 1023 +|=(% style="width: 163px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 290px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1024 +|(% style="width:155px" %)AT+CLRC|(% style="width:259px" %)clear the open door times and the duration of the last open door.|(% style="width:44px" %)((( 1025 +OK 903 903 ))) 904 904 905 -* ((( 906 -Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1028 +(% style="color:blue" %)**Downlink Command:**(%%)0xA6 01 1029 + 1030 +The sensor will clear the open door times and the duration of the last open door. 1031 + 1032 + 1033 +=== 3.3.10 Set the count value of the number of open door === 1034 + 1035 + 1036 +(% style="color:blue" %)**AT Command:** 1037 + 1038 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %) 1039 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 288px; background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 57px;background-color:#D9E2F3;color:#0070C0" %)**Response** 1040 +|(% style="width:155px" %)((( 1041 +AT+SETCNT=1,100 1042 +)))|(% style="width:259px" %)((( 1043 +Set the open door times of PA8 pin to 100 times. 1044 +)))|(% style="width:44px" %)((( 1045 +OK 907 907 ))) 908 -* ((( 909 -Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1047 +|(% style="width:155px" %)AT+SETCNT=1,0|(% style="width:259px" %)Clear the open door times of PA8 pin.|(% style="width:44px" %)OK 1048 +|(% style="width:155px" %)((( 1049 +AT+SETCNT=2,50 1050 +)))|(% style="width:259px" %)((( 1051 +Set the open door times of PA4 pin to 100 times. 1052 +)))|(% style="width:44px" %)((( 1053 +OK 910 910 ))) 911 911 912 -= 3. ConfigureSW3L-NB =1056 +(% style="color:blue" %)**Downlink Command:** 913 913 1058 +0xA6 01 00 00 64 ==> AT+SETCNT=1,100 1059 + 1060 +0xA6 01 00 00 00 ==> AT+SETCNT=1,0 1061 + 1062 +0xA6 02 00 00 32 ==> AT+SETCNT=2,50 1063 + 1064 + 1065 += 3. Configure DS03A-NB = 1066 + 914 914 == 3.1 Configure Methods == 915 915 916 916 917 -S W3L-NB supports below configure method:1070 +DS03A-NB supports below configure method: 918 918 919 919 * AT Command via Bluetooth Connection (**Recommended**): [[BLE Configure Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 920 920 ... ... @@ -1003,7 +1003,7 @@ 1003 1003 = 4. Battery & Power Consumption = 1004 1004 1005 1005 1006 -S W3L-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.1159 +DS03A-NB use ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 1007 1007 1008 1008 [[**Battery Info & Power Consumption Analyze**>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 1009 1009 ... ... @@ -1038,7 +1038,7 @@ 1038 1038 = 7. Order Info = 1039 1039 1040 1040 1041 -Part Number: (% style="color:blue" %)**S W3L-NB-XX-YY**1194 +Part Number: (% style="color:blue" %)**DS03A-NB-XX** 1042 1042 1043 1043 (% style="color:red" %)**XX**(%%): 1044 1044 ... ... @@ -1048,43 +1048,14 @@ 1048 1048 1049 1049 (% style="color:#037691" %)**1NCE SIM Card NB-IoT network coverage**(%%): Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 1050 1050 1051 -((( 1052 -(% style="color:blue" %)**YY**(%%): Flow Sensor Model: 1053 -))) 1054 1054 1055 -((( 1056 - **004:** DW-004 Flow Sensor: diameter: G1/2” / DN15. 450 pulse = 1 L 1057 -))) 1058 1058 1059 -((( 1060 - **006:** DW-006 Flow Sensor: diameter: G3/4” / DN20. 390 pulse = 1 L 1061 -))) 1062 - 1063 -((( 1064 - **010:** DW-010 Flow Sensor: diameter: G 1” / DN25. 64 pulse = 1 L 1065 -))) 1066 - 1067 -* ((( 1068 -calculate flag=0: for SW3L-004 Flow Sensor: 450 pulse = 1 L 1069 -))) 1070 - 1071 -* ((( 1072 -calculate flag=1: for SW3L-006 Flow Sensor: 390 pulse = 1 L 1073 -))) 1074 - 1075 -* ((( 1076 -calculate flag=2: for SW3L-010 Flow Sensor: 64 pulse = 1 L 1077 - 1078 - 1079 - 1080 -))) 1081 - 1082 1082 = 8. Packing Info = 1083 1083 1084 1084 1085 1085 (% style="color:#037691" %)**Package Includes**: 1086 1086 1087 -* S W3L-NB NB-IoT Distance Detectionsensor x 11211 +* DS03A-NB NB-IoT Door sensor x 1 1088 1088 1089 1089 * External antenna x 1 1090 1090
- image-20231011092549-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +548.0 KB - Content
- image-20231011092656-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +548.0 KB - Content
- image-20231011092728-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +245.9 KB - Content
- image-20231011092834-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +550.2 KB - Content
- image-20231011093014-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +249.4 KB - Content
- image-20231011093807-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +196.7 KB - Content