Changes for page wiki_test
Last modified by Mengting Qiu on 2024/09/05 17:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -400,7 +400,7 @@ 400 400 SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server. 401 401 402 402 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 403 -|(% style="background-color:# d9e2f3;#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3;#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3;#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3;#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3;#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3;#0070c0; width:74px" %)**1**403 +|(% style="background-color:#4F81BD;color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:105px" %)**3**|(% style="background-color:#4F81BD;color:white; width:60px" %)**1**|(% style="background-color:#4F81BD;color:white; width:96px" %)**1**|(% style="background-color:#4F81BD;color:white; width:105px" %)**2**|(% style="background-color:#4F81BD;color:white; width:74px" %)**1** 404 404 |**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve 405 405 406 406 Example parse in TTNv3 ... ... @@ -415,7 +415,7 @@ 415 415 416 416 * (% style="color:blue" %)**STOP Duration & Alarm Timer** 417 417 418 -Shows the configure value of [[Alarm for continuously water flow>>||anchor="H 3.3.4Alarmforcontinuouslywaterflow"]]418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]] 419 419 420 420 421 421 === 2.3.2 Water Flow Value, Uplink FPORT~=2 === ... ... @@ -872,6 +872,48 @@ 872 872 873 873 * **Example**: 0xA6000064 ~/~/ Same as AT+ SETCNT =100 874 874 875 +== 2.10 Set Transmit Interval Time == 876 + 877 + 878 +((( 879 +Feature: Change NB-IoT End Node Transmit Interval. 880 +))) 881 + 882 +((( 883 +(% style="color:blue" %)**AT Command: AT+TDC** 884 +))) 885 + 886 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 887 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3; color:#0070c0" %)**Function**|=(% style="background-color:#D9E2F3; color:#0070c0" %)**Response** 888 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 889 +30000 890 +OK 891 +the interval is 30000ms = 30s 892 +))) 893 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 894 +OK 895 +Set transmit interval to 60000ms = 60 seconds 896 +))) 897 + 898 +((( 899 +(% style="color:blue" %)**Downlink Command: 0x01** 900 +))) 901 + 902 +((( 903 +Format: Command Code (0x01) followed by 3 bytes time value. 904 +))) 905 + 906 +((( 907 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 908 +))) 909 + 910 +* ((( 911 +Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 912 +))) 913 +* ((( 914 +Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 915 +))) 916 + 875 875 = 3. Configure SW3L-NB = 876 876 877 877 == 3.1 Configure Methods ==