Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 101.14
edited by Xiaoling
on 2023/10/10 15:37
Change comment: There is no comment for this version
To version 101.12
edited by Xiaoling
on 2023/10/10 15:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -397,7 +397,7 @@
397 397  === 2.3.1 Sensor Configuration, FPORT~=4 ===
398 398  
399 399  
400 -SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server.
400 +SW3L-LB will only send this command after getting the downlink command **(0x26 02)** from the server.
401 401  
402 402  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
403 403  |(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
... ... @@ -422,7 +422,7 @@
422 422  
423 423  
424 424  (((
425 -SW3L-NB will send this uplink **after** Device Status once join the NB-IoT network successfully. And SW3L-NB will:
425 +SW3L-LB will send this uplink **after** Device Status once join the LoRaWAN network successfully. And SW3L-LB will:
426 426  )))
427 427  
428 428  (((
... ... @@ -611,7 +611,7 @@
611 611  
612 612  
613 613  (((
614 -SW3L-NB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
614 +SW3L-LB stores sensor values and users can retrieve these history values via the [[downlink command>>||anchor="H2.5DatalogFeature"]].
615 615  )))
616 616  
617 617  (((
... ... @@ -666,7 +666,7 @@
666 666  )))
667 667  
668 668  (((
669 -If SW3L-NB doesn't have any data in the polling time. It will uplink 11 bytes of 0
669 +If SW3L-LB doesn't have any data in the polling time. It will uplink 11 bytes of 0
670 670  
671 671  
672 672  )))
... ... @@ -782,7 +782,7 @@
782 782  )))
783 783  
784 784  (((
785 -Default: 15s, If SW3L-NB didn't see any water flow in 15s, SW3L-NB will consider stop of water flow event.
785 +Default: 15s, If SW3L-LB didn't see any water flow in 15s, SW3L-LB will consider stop of water flow event.
786 786  )))
787 787  
788 788  * (((
... ... @@ -790,7 +790,7 @@
790 790  )))
791 791  
792 792  (((
793 -**Example:** 3 minutes, if SW3L-NB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-NB will send an Alarm to indicate a water flow abnormal alarm.
793 +**Example:** 3 minutes, if SW3L-LB detect a start of water flow event and didn't detect a stop event within Alarm timer, SW3L-LB will send an Alarm to indicate a water flow abnormal alarm.
794 794  )))
795 795  
796 796  (((
... ... @@ -854,6 +854,7 @@
854 854  
855 855  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
856 856  
857 +
857 857  == 2.9 Set count number ==
858 858  
859 859  
... ... @@ -872,6 +872,7 @@
872 872  
873 873  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
874 874  
876 +
875 875  = 3. Configure SW3L-NB =
876 876  
877 877  == 3.1 Configure Methods ==