Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 101.13
edited by Xiaoling
on 2023/10/10 15:23
Change comment: There is no comment for this version
To version 101.24
edited by Xiaoling
on 2023/10/10 17:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -106,7 +106,7 @@
106 106  
107 107  (((
108 108  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
109 -|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Model**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Probe**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Diameter**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Range**|=(% style="width: 80px;background-color:#D9E2F3;color:#0070C0" %)**Max Pressure**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Measure**
109 +|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Model**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Probe**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Diameter**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Range**|=(% style="width: 80px;background-color:#4F81BD;color:white" %)**Max Pressure**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Measure**
110 110  |(% style="width:88px" %)SW3L-004|(% style="width:75px" %)DW-004|(% style="width:107px" %)G1/2" /DN15|(% style="width:101px" %)1~~30L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)450 pulse = 1 L
111 111  |(% style="width:88px" %)SW3L-006|(% style="width:75px" %)DW-006|(% style="width:107px" %)G3/4" /DN20|(% style="width:101px" %)1~~60L/min|(% style="width:116px" %)≤ 1.2Mpa|(% style="width:124px" %)390 pulse = 1 L
112 112  |(% style="width:88px" %)SW3L-010|(% style="width:75px" %)DW-010|(% style="width:107px" %)G 1" /DN25|(% style="width:101px" %)2~~100L/min|(% style="width:116px" %)≤ 2.0Mpa|(% style="width:124px" %)64 pulse = 1 L
... ... @@ -400,7 +400,7 @@
400 400  SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server.
401 401  
402 402  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
403 -|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
403 +|(% style="background-color:#4F81BD;color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:105px" %)**3**|(% style="background-color:#4F81BD;color:white; width:60px" %)**1**|(% style="background-color:#4F81BD;color:white; width:96px" %)**1**|(% style="background-color:#4F81BD;color:white; width:105px" %)**2**|(% style="background-color:#4F81BD;color:white; width:74px" %)**1**
404 404  |**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
405 405  
406 406  Example parse in TTNv3
... ... @@ -415,7 +415,7 @@
415 415  
416 416  * (% style="color:blue" %)**STOP Duration & Alarm Timer**
417 417  
418 -Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]
419 419  
420 420  
421 421  === 2.3.2 Water Flow Value, Uplink FPORT~=2 ===
... ... @@ -426,7 +426,7 @@
426 426  )))
427 427  
428 428  (((
429 -periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H3.3.1SetTransmitIntervalTime"]].
429 +periodically send this uplink every 20 minutes, this interval [[can be changed>>||anchor="H2.10SetTransmitIntervalTime"]].
430 430  )))
431 431  
432 432  (((
... ... @@ -434,9 +434,9 @@
434 434  )))
435 435  
436 436  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
437 -|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=2**
437 +|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value,  FPORT=2**
438 438  |(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4**
439 -|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
439 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
440 440  Total pulse Or Last Pulse
441 441  )))|(% style="width:78px" %)(((
442 442  MOD & PA4_status & PB15_status
... ... @@ -445,13 +445,13 @@
445 445  **Calculate Flag & Alarm:**
446 446  
447 447  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:500px" %)
448 -|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)**[bit7:bit6]**|(% style="background-color:#d9e2f3; color:#0070c0; width:90px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:130px" %)**bit0**
448 +|(% style="background-color:#4F81BD;color:white; width:70px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:70px" %)**[bit7:bit6]**|(% style="background-color:#4F81BD;color:white; width:90px" %)**[bit5:bit2]**|(% style="background-color:#4F81BD;color:white; width:140px" %)**bit1**|(% style="background-color:#4F81BD;color:white; width:130px" %)**bit0**
449 449  |(% style="width:88px" %)**Value**|(% style="width:117px" %)Reserve|(% style="width:117px" %)Calculate Flag|(% style="width:169px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:150px" %)TDC flag 0:No;1:Yes
450 450  
451 451  **MOD & PA4_status & PB15_status:**
452 452  
453 453  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:230px" %)
454 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]**
454 +|(% style="background-color:#4F81BD;color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit7**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit6**|(% style="background-color:#4F81BD;color:white; width:60px" %)**[bit5:bit0]**
455 455  |(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD
456 456  
457 457  (% style="color:#037691" %)** **[[image:image-20230626093242-1.png||height="276" width="892"]]
... ... @@ -463,8 +463,6 @@
463 463  
464 464  (((
465 465  The calculate flag is a user defined field, IoT server can use this flag to handle different meters with different pulse factors. For example, if there are 100 Flow Sensors, meters 1 ~~50 are 1 liter/pulse and meters 51 ~~ 100 has 1.5 liter/pulse.
466 -
467 -
468 468  )))
469 469  
470 470  (((
... ... @@ -509,7 +509,7 @@
509 509  )))
510 510  
511 511  (((
512 -See [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
510 +See [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]
513 513  )))
514 514  
515 515  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SW3L%20LoRaWAN%20Outdoor%20Flow%20Sensor/WebHome/image-20220519095946-4.png?width=724&height=65&rev=1.1||alt="image-20220519095946-4.png"]]
... ... @@ -618,9 +618,9 @@
618 618  The historical payload includes one or multiplies entries and every entry has the same payload as Real-Time water flow status.
619 619  
620 620  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
621 -|=(% colspan="6" style="width: 515px; background-color:#D9E2F3;color:#0070C0" %)**Water Flow Value,  FPORT=3**
619 +|=(% colspan="6" style="width: 515px; background-color:#4F81BD;color:white" %)**Water Flow Value,  FPORT=3**
622 622  |(% style="width:50px" %)**Size(bytes)**|(% style="width:110px" %)**1**|(% style="width:120px" %)**4**|(% style="width:110px" %)**1**|(% style="width:55px" %)**1**|(% style="width:70px" %)**4**
623 -|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
621 +|(% style="width:110px" %)**Value**|(% style="width:81px" %)Calculate Flag & [[Alarm>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]|(% style="width:95px" %)(((
624 624  Total pulse Or Last Pulse
625 625  )))|(% style="width:78px" %)(((
626 626  MOD & PA4_status & PB15_status
... ... @@ -629,7 +629,7 @@
629 629  **Calculate Flag & Alarm:**
630 630  
631 631  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:515px" %)
632 -|(% style="background-color:#d9e2f3; color:#0070c0; width:50px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:69px" %)**[bit5:bit2]**|(% style="background-color:#d9e2f3; color:#0070c0; width:129px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit0**
630 +|(% style="background-color:#4F81BD;color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:89px" %)**bit7**|(% style="background-color:#4F81BD;color:white; width:89px" %)**bit6**|(% style="background-color:#4F81BD;color:white; width:69px" %)**[bit5:bit2]**|(% style="background-color:#4F81BD;color:white; width:129px" %)**bit1**|(% style="background-color:#d9e2f3; color:#0070c0; width:89px" %)**bit0**
633 633  |(% style="width:88px" %)**Value**|(% style="width:96px" %)(((
634 634  No ACK message
635 635  )))|(% style="width:94px" %)Poll Message Flag|(% style="width:115px" %)Calculate Flag|(% style="width:136px" %)Alarm: 0: No Alarm; 1: Alarm|(% style="width:120px" %)TDC flag 0:No;1:Yes
... ... @@ -637,12 +637,12 @@
637 637  **MOD & PA4_status & PB15_status:**
638 638  
639 639  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:240px" %)
640 -|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**Size(bit)**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit7**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**bit6**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**[bit5:bit0]**
638 +|(% style="background-color:#4F81BD;color:white; width:60px" %)**Size(bit)**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit7**|(% style="background-color:#4F81BD;color:white; width:60px" %)**bit6**|(% style="background-color:#4F81BD;color:white; width:60px" %)**[bit5:bit0]**
641 641  |(% style="width:88px" %)**Value**|(% style="width:117px" %)PA4_status|(% style="width:117px" %)PB15_status|(% style="width:118px" %)MOD
642 642  )))
643 643  
644 644  * (((
645 -Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.3A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
643 +Each data entry is 11 bytes and has the same structure as [[real time water flow status>>||anchor="H2.3.2A0WaterFlowValue2CUplinkFPORT3D2"]], to save airtime and battery, SW3L will send max bytes according to the current DR and Frequency bands.
646 646  )))
647 647  
648 648  (((
... ... @@ -846,7 +846,7 @@
846 846  (% style="color:blue" %)**AT Command: AT+CALCFLAG**
847 847  
848 848  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:461px" %)
849 -|=(% style="width: 158px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 193px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 110px;background-color:#D9E2F3;color:#0070C0" %)**Response**
847 +|=(% style="width: 158px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 193px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 110px;background-color:#4F81BD;color:white" %)**Response**
850 850  |(% style="width:158px" %)AT+CALCFLAG =1|(% style="width:192px" %)Set the calculate flag to 1.|(% style="width:109px" %)OK
851 851  |(% style="width:158px" %)AT+CALCFLAG =2|(% style="width:192px" %)Set the calculate flag to 2.|(% style="width:109px" %)OK
852 852  
... ... @@ -854,7 +854,6 @@
854 854  
855 855  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
856 856  
857 -
858 858  == 2.9 Set count number ==
859 859  
860 860  
... ... @@ -863,7 +863,7 @@
863 863  (% style="color:blue" %)**AT Command: AT+SETCNT**
864 864  
865 865  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:479px" %)
866 -|=(% style="width: 160px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 223px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 96px;background-color:#D9E2F3;color:#0070C0" %)**Response**
863 +|=(% style="width: 160px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 223px;background-color:#4F81BD;color:white" %)**Function**|=(% style="width: 96px;background-color:#4F81BD;color:white" %)**Response**
867 867  |(% style="width:160px" %)AT+ SETCNT =0|(% style="width:221px" %)Set the count number to 0.|(% style="width:95px" %)OK
868 868  |(% style="width:160px" %)AT+ SETCNT =100|(% style="width:221px" %)Set the count number to 100.|(% style="width:95px" %)OK
869 869  
... ... @@ -873,7 +873,48 @@
873 873  
874 874  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
875 875  
873 +== 2.10 Set Transmit Interval Time ==
876 876  
875 +
876 +(((
877 +Feature: Change NB-IoT End Node Transmit Interval.
878 +)))
879 +
880 +(((
881 +(% style="color:blue" %)**AT Command: AT+TDC**
882 +)))
883 +
884 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
885 +|=(% style="width: 156px;background-color:#4F81BD;color:white" %)**Command Example**|=(% style="width: 137px;background-color:#4F81BD;color:white" %)**Function**|=(% style="background-color:#4F81BD;color:white" %)**Response**
886 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
887 +30000
888 +OK
889 +the interval is 30000ms = 30s
890 +)))
891 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
892 +OK
893 +Set transmit interval to 60000ms = 60 seconds
894 +)))
895 +
896 +(((
897 +(% style="color:blue" %)**Downlink Command: 0x01**
898 +)))
899 +
900 +(((
901 +Format: Command Code (0x01) followed by 3 bytes time value.
902 +)))
903 +
904 +(((
905 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
906 +)))
907 +
908 +* (((
909 +Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
910 +)))
911 +* (((
912 +Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
913 +)))
914 +
877 877  = 3. Configure SW3L-NB =
878 878  
879 879  == 3.1 Configure Methods ==
... ... @@ -1000,48 +1000,9 @@
1000 1000  [[See BC660K-GL AT Command set>>url:https://www.dropbox.com/sh/5f6ssda5fum8rvs/AABT68l8ZzWOvZ5eg2qwOoFda?dl=0]]
1001 1001  
1002 1002  
1003 -== 6.2 Can I use SW3L-NB in condensation environment? ==
1041 += 7. Order Info =
1004 1004  
1005 1005  
1006 -SW3L-NB is not suitable to be used in condensation environment. Condensation on the SW3L-NB probe will affect the reading and always got 0.
1007 -
1008 -
1009 -= 7. Trouble Shooting =
1010 -
1011 -== 7.1 Why does the sensor reading show 0 or "No sensor" ==
1012 -
1013 -
1014 -~1. The measurement object is very close to the sensor, but in the blind spot of the sensor.
1015 -
1016 -2. Sensor wiring is disconnected
1017 -
1018 -3. Not using the correct decoder
1019 -
1020 -
1021 -== 7.2 Abnormal readings The gap between multiple readings is too large or the gap between the readings and the actual value is too large ==
1022 -
1023 -
1024 -1) Please check if there is something on the probe affecting its measurement (condensed water, volatile oil, etc.)
1025 -
1026 -2) Does it change with temperature, temperature will affect its measurement
1027 -
1028 -3) If abnormal data occurs, you can turn on DEBUG mode, Please use downlink or AT COMMAN to enter DEBUG mode.
1029 -
1030 -downlink command: (% style="color:blue" %)**F1 01**(%%), AT command: (% style="color:blue" %)**AT+DDEBUG=1**
1031 -
1032 -4) After entering the debug mode, it will send 20 pieces of data at a time, and you can send its uplink to us for analysis
1033 -
1034 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20230113135125-2.png?width=1057&height=136&rev=1.1||alt="image-20230113135125-2.png"]]
1035 -
1036 -
1037 -Its original payload will be longer than other data. Even though it is being parsed, it can be seen that it is abnormal data.
1038 -
1039 -Please send the data to us for check.
1040 -
1041 -
1042 -= 8. Order Info =
1043 -
1044 -
1045 1045  Part Number: (% style="color:blue" %)**SW3L-NB-XX-YY**
1046 1046  
1047 1047  (% style="color:red" %)**XX**(%%):
... ... @@ -1083,7 +1083,7 @@
1083 1083  
1084 1084  )))
1085 1085  
1086 -= 9. ​Packing Info =
1085 += 8. ​Packing Info =
1087 1087  
1088 1088  
1089 1089  (% style="color:#037691" %)**Package Includes**:
... ... @@ -1102,7 +1102,7 @@
1102 1102  
1103 1103  * Weight / pcs : 180g
1104 1104  
1105 -= 10. Support =
1104 += 9. Support =
1106 1106  
1107 1107  
1108 1108  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.