Changes for page wiki_test

Last modified by Mengting Qiu on 2024/09/05 17:35

From version 101.13
edited by Xiaoling
on 2023/10/10 15:23
Change comment: There is no comment for this version
To version 101.19
edited by Xiaoling
on 2023/10/10 15:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -400,7 +400,7 @@
400 400  SW3L-NB will only send this command after getting the downlink command **(0x26 02)** from the server.
401 401  
402 402  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
403 -|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %) **Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**3**|(% style="background-color:#d9e2f3; color:#0070c0; width:60px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:96px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:105px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:74px" %)**1**
403 +|(% style="background-color:#4F81BD;color:white; width:70px" %) **Size(bytes)**|(% style="background-color:#4F81BD;color:white; width:105px" %)**3**|(% style="background-color:#4F81BD;color:white; width:60px" %)**1**|(% style="background-color:#4F81BD;color:white; width:96px" %)**1**|(% style="background-color:#4F81BD;color:white; width:105px" %)**2**|(% style="background-color:#4F81BD;color:white; width:74px" %)**1**
404 404  |**Value**|(% style="width:104px" %)TDC(unit:sec)|(% style="width:43px" %)N/A|(% style="width:91px" %)Stop Timer|(% style="width:100px" %)Alarm Timer|(% style="width:69px" %)Reserve
405 405  
406 406  Example parse in TTNv3
... ... @@ -415,7 +415,7 @@
415 415  
416 416  * (% style="color:blue" %)**STOP Duration & Alarm Timer**
417 417  
418 -Shows the configure value of [[Alarm for continuously water flow>>||anchor="H3.3.4Alarmforcontinuouslywaterflow"]]
418 +Shows the configure value of [[Alarm for continuously water flow>>||anchor="H2.7Alarmforcontinuouslywaterflow"]]
419 419  
420 420  
421 421  === 2.3.2 Water Flow Value, Uplink FPORT~=2 ===
... ... @@ -854,7 +854,6 @@
854 854  
855 855  * **Example**: 0XA501  ~/~/  Same as AT+CALCFLAG =1
856 856  
857 -
858 858  == 2.9 Set count number ==
859 859  
860 860  
... ... @@ -873,7 +873,48 @@
873 873  
874 874  * **Example**: 0xA6000064  ~/~/  Same as AT+ SETCNT =100
875 875  
875 +== 2.10 Set Transmit Interval Time ==
876 876  
877 +
878 +(((
879 +Feature: Change NB-IoT End Node Transmit Interval.
880 +)))
881 +
882 +(((
883 +(% style="color:blue" %)**AT Command: AT+TDC**
884 +)))
885 +
886 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
887 +|=(% style="width: 156px;background-color:#D9E2F3; color:#0070c0" %)**Command Example**|=(% style="width: 137px;background-color:#D9E2F3; color:#0070c0" %)**Function**|=(% style="background-color:#D9E2F3; color:#0070c0" %)**Response**
888 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
889 +30000
890 +OK
891 +the interval is 30000ms = 30s
892 +)))
893 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
894 +OK
895 +Set transmit interval to 60000ms = 60 seconds
896 +)))
897 +
898 +(((
899 +(% style="color:blue" %)**Downlink Command: 0x01**
900 +)))
901 +
902 +(((
903 +Format: Command Code (0x01) followed by 3 bytes time value.
904 +)))
905 +
906 +(((
907 +If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
908 +)))
909 +
910 +* (((
911 +Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
912 +)))
913 +* (((
914 +Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
915 +)))
916 +
877 877  = 3. Configure SW3L-NB =
878 878  
879 879  == 3.1 Configure Methods ==