Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -63,7 +63,6 @@ 63 63 ** Idle: 6uA@3.3v 64 64 ** 20dB Transmit: 130mA@3.3v 65 65 66 - 67 67 **Interface for Model:** 68 68 69 69 * 1 x RS485 Interface ... ... @@ -73,7 +73,6 @@ 73 73 * 1 x Interrupt Interface 74 74 * 1 x Controllable 5V output, max 75 75 76 - 77 77 **LoRa Spec:** 78 78 79 79 * Frequency Range: ... ... @@ -92,9 +92,6 @@ 92 92 * 127 dB Dynamic Range RSSI. 93 93 * Automatic RF Sense and CAD with ultra-fast AFC. 94 94 95 - 96 - 97 - 98 98 == 1.3 Features == 99 99 100 100 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -106,9 +106,6 @@ 106 106 * Support Modbus protocol 107 107 * Support Interrupt uplink 108 108 109 - 110 - 111 - 112 112 == 1.4 Applications == 113 113 114 114 * Smart Buildings & Home Automation ... ... @@ -118,9 +118,6 @@ 118 118 * Smart Cities 119 119 * Smart Factory 120 120 121 - 122 - 123 - 124 124 == 1.5 Firmware Change log == 125 125 126 126 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -204,7 +204,6 @@ 204 204 205 205 [[image:1652953414711-647.png||height="337" width="723"]] 206 206 207 - 208 208 ((( 209 209 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 210 210 ))) ... ... @@ -223,13 +223,12 @@ 223 223 224 224 [[image:1652953462722-299.png]] 225 225 226 - 227 227 ((( 228 228 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 229 229 ))) 230 230 231 231 ((( 232 - **Add APP EUI in the application.**223 +Add APP EUI in the application. 233 233 ))) 234 234 235 235 ... ... @@ -241,7 +241,6 @@ 241 241 242 242 [[image:image-20220519174512-4.png]] 243 243 244 - 245 245 You can also choose to create the device manually. 246 246 247 247 [[image:1652953542269-423.png||height="710" width="723"]] ... ... @@ -293,28 +293,28 @@ 293 293 ))) 294 294 295 295 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 296 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 297 297 ((( 298 298 **AT Commands** 299 299 ))) 300 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 301 301 ((( 302 302 **Description** 303 303 ))) 304 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 305 305 ((( 306 306 **Example** 307 307 ))) 308 308 ))) 309 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 310 310 ((( 311 311 AT+BAUDR 312 312 ))) 313 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 314 314 ((( 315 315 Set the baud rate (for RS485 connection). Default Value is: 9600. 316 316 ))) 317 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 318 318 ((( 319 319 ((( 320 320 AT+BAUDR=9600 ... ... @@ -327,11 +327,11 @@ 327 327 ))) 328 328 ))) 329 329 ))) 330 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 331 331 ((( 332 332 AT+PARITY 333 333 ))) 334 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 335 335 ((( 336 336 ((( 337 337 Set UART parity (for RS485 connection) ... ... @@ -343,7 +343,7 @@ 343 343 Default Value is: no parity. 344 344 ))) 345 345 ))) 346 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 347 347 ((( 348 348 ((( 349 349 AT+PARITY=0 ... ... @@ -356,11 +356,11 @@ 356 356 ))) 357 357 ))) 358 358 ))) 359 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 360 360 ((( 361 361 AT+STOPBIT 362 362 ))) 363 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 364 364 ((( 365 365 ((( 366 366 Set serial stopbit (for RS485 connection) ... ... @@ -372,7 +372,7 @@ 372 372 Default Value is: 1bit. 373 373 ))) 374 374 ))) 375 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 376 376 ((( 377 377 ((( 378 378 AT+STOPBIT=0 for 1bit ... ... @@ -392,6 +392,8 @@ 392 392 ))) 393 393 ))) 394 394 385 + 386 + 395 395 === 3.3.2 Configure sensors === 396 396 397 397 ((( ... ... @@ -403,20 +403,14 @@ 403 403 ))) 404 404 405 405 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 406 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 407 -|AT+CFGDEV|(% style="width:80px" %)((( 408 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 409 409 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 410 -))) 411 411 412 -((( 413 413 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 414 -))) 415 415 416 -((( 417 417 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 418 -))) 419 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 420 420 421 421 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 422 422 ... ... @@ -916,6 +916,8 @@ 916 916 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 917 917 ))) 918 918 905 + 906 + 919 919 === 3.5.1 Common Commands: === 920 920 921 921 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -951,101 +951,53 @@ 951 951 952 952 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 953 953 954 -((( 955 955 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 956 -))) 957 957 958 -* ((( 959 -**AT Command** 960 -))) 944 +* **AT Command** 961 961 962 962 (% class="box infomessage" %) 963 963 ((( 964 -((( 965 965 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 966 966 ))) 967 -))) 968 968 969 -((( 970 970 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 971 -))) 972 972 973 -((( 974 - 975 -))) 976 976 977 -* ((( 978 -**Downlink Payload** 979 -))) 954 +* **Downlink Payload** 980 980 981 -((( 982 982 Format: A8 MM NN XX XX XX XX YY 983 -))) 984 984 985 -((( 986 986 Where: 987 -))) 988 988 989 -* ((( 990 -MM: 1: add CRC-16/MODBUS ; 0: no CRC 991 -))) 992 -* ((( 993 -NN: The length of RS485 command 994 -))) 995 -* ((( 996 -XX XX XX XX: RS485 command total NN bytes 997 -))) 998 -* ((( 999 -YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 1000 -))) 960 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC 961 +* NN: The length of RS485 command 962 +* XX XX XX XX: RS485 command total NN bytes 963 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 1001 1001 1002 -((( 1003 1003 **Example 1:** 1004 -))) 1005 1005 1006 -((( 1007 1007 To connect a Modbus Alarm with below commands. 1008 -))) 1009 1009 1010 -* ((( 1011 -The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1012 -))) 969 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1013 1013 1014 -* ((( 1015 -The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1016 -))) 971 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1017 1017 1018 -((( 1019 1019 So if user want to use downlink command to control to RS485 Alarm, he can use: 1020 -))) 1021 1021 1022 -((( 1023 1023 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 1024 -))) 1025 1025 1026 -((( 1027 1027 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 1028 -))) 1029 1029 1030 1030 ((( 1031 1031 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 1032 1032 ))) 1033 1033 1034 -((( 1035 - 1036 -))) 1037 1037 1038 -((( 1039 1039 **Example 2:** 1040 -))) 1041 1041 1042 -((( 1043 1043 Check TTL Sensor return: 1044 -))) 1045 1045 1046 -((( 1047 1047 [[image:1654132684752-193.png]] 1048 -))) 1049 1049 1050 1050 1051 1051 ... ... @@ -1074,121 +1074,62 @@ 1074 1074 1075 1075 ==== **Set RS485 Sampling Commands** ==== 1076 1076 1077 -((( 1078 1078 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 1079 -))) 1080 1080 1081 -((( 1082 1082 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1083 -))) 1084 1084 1085 -((( 1086 - 1087 -))) 1088 1088 1089 -* ((( 1090 -**AT Command:** 1091 -))) 1022 +* **AT Command:** 1092 1092 1093 1093 (% class="box infomessage" %) 1094 1094 ((( 1095 -((( 1096 1096 **AT+COMMANDx: Configure RS485 read command to sensor.** 1097 1097 ))) 1098 -))) 1099 1099 1100 1100 (% class="box infomessage" %) 1101 1101 ((( 1102 -((( 1103 1103 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 1104 1104 ))) 1105 -))) 1106 1106 1107 1107 (% class="box infomessage" %) 1108 1108 ((( 1109 -((( 1110 1110 **AT+SEARCHx: Configure search command** 1111 1111 ))) 1112 -))) 1113 1113 1114 -((( 1115 - 1116 -))) 1117 1117 1118 -* ((( 1119 -**Downlink Payload:** 1120 -))) 1040 +* **Downlink Payload:** 1121 1121 1122 -((( 1123 1123 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 1124 -))) 1125 1125 1126 -((( 1127 1127 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 1128 -))) 1129 1129 1130 -((( 1131 1131 Format: AF MM NN LL XX XX XX XX YY 1132 -))) 1133 1133 1134 -((( 1135 1135 Where: 1136 -))) 1137 1137 1138 -* ((( 1139 -MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 1140 -))) 1141 -* ((( 1142 -NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 1143 -))) 1144 -* ((( 1145 -LL: The length of AT+COMMAND or AT+DATACUT command 1146 -))) 1147 -* ((( 1148 -XX XX XX XX: AT+COMMAND or AT+DATACUT command 1149 -))) 1150 -* ((( 1151 -YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 1152 -))) 1050 +* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 1051 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 1052 +* LL: The length of AT+COMMAND or AT+DATACUT command 1053 +* XX XX XX XX: AT+COMMAND or AT+DATACUT command 1054 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 1153 1153 1154 -((( 1155 1155 **Example:** 1156 -))) 1157 1157 1158 -((( 1159 1159 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 1160 -))) 1161 1161 1162 -((( 1163 1163 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 1164 -))) 1165 1165 1166 -((( 1167 1167 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 1168 -))) 1169 1169 1170 -((( 1171 - 1172 -))) 1173 1173 1174 -((( 1175 1175 **0xAB** downlink command can be used for set AT+SEARCHx 1176 -))) 1177 1177 1178 -((( 1179 1179 **Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 1180 -))) 1181 1181 1182 -* ((( 1183 -AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 1184 -))) 1185 -* ((( 1186 -AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 1187 -))) 1069 +* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 1070 +* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 1188 1188 1189 -((( 1190 1190 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 1191 -))) 1192 1192 1193 1193 1194 1194 ... ... @@ -1195,47 +1195,24 @@ 1195 1195 1196 1196 ==== **Fast command to handle MODBUS device** ==== 1197 1197 1198 -((( 1199 1199 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 1200 -))) 1201 1201 1202 -((( 1203 1203 This command is valid since v1.3 firmware version 1204 -))) 1205 1205 1206 -((( 1207 - 1208 -))) 1209 1209 1210 -((( 1211 1211 **AT+MBFUN has only two value:** 1212 -))) 1213 1213 1214 -* ((( 1215 -**AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 1216 -))) 1086 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 1217 1217 1218 -((( 1219 1219 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 1220 -))) 1221 1221 1222 -* ((( 1223 -**AT+MBFUN=0**: Disable Modbus fast reading. 1224 -))) 1090 +* **AT+MBFUN=0**: Disable Modbus fast reading. 1225 1225 1226 -((( 1227 1227 **Example:** 1228 -))) 1229 1229 1230 -* ((( 1231 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 1232 -))) 1233 -* ((( 1234 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 1235 -))) 1236 -* ((( 1237 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 1238 -))) 1094 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 1095 +* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 1096 +* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 1239 1239 1240 1240 [[image:1654133913295-597.png]] 1241 1241 ... ... @@ -1243,13 +1243,9 @@ 1243 1243 [[image:1654133954153-643.png]] 1244 1244 1245 1245 1246 -* ((( 1247 -**Downlink Commands:** 1248 -))) 1104 +* **Downlink Commands:** 1249 1249 1250 -((( 1251 1251 **A9 aa** ~-~-> Same as AT+MBFUN=aa 1252 -))) 1253 1253 1254 1254 1255 1255 ... ... @@ -1256,60 +1256,32 @@ 1256 1256 1257 1257 ==== **RS485 command timeout** ==== 1258 1258 1259 -((( 1260 1260 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1261 -))) 1262 1262 1263 -((( 1264 1264 Default value: 0, range: 0 ~~ 5 seconds 1265 -))) 1266 1266 1267 -((( 1268 - 1269 -))) 1270 1270 1271 -* ((( 1272 -**AT Command:** 1273 -))) 1118 +* **AT Command:** 1274 1274 1275 1275 (% class="box infomessage" %) 1276 1276 ((( 1277 -((( 1278 1278 **AT+CMDDLaa=hex(bb cc)** 1279 1279 ))) 1280 -))) 1281 1281 1282 -((( 1283 1283 **Example:** 1284 -))) 1285 1285 1286 -((( 1287 1287 **AT+CMDDL1=1000** to send the open time to 1000ms 1288 -))) 1289 1289 1290 -((( 1291 - 1292 -))) 1293 1293 1294 -* ((( 1295 -**Downlink Payload:** 1296 -))) 1130 +* **Downlink Payload:** 1297 1297 1298 -((( 1299 1299 0x AA aa bb cc 1300 -))) 1301 1301 1302 -((( 1303 1303 Same as: AT+CMDDLaa=hex(bb cc) 1304 -))) 1305 1305 1306 -((( 1307 1307 **Example:** 1308 -))) 1309 1309 1310 -((( 1311 1311 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1312 -))) 1313 1313 1314 1314 1315 1315 ... ... @@ -1316,47 +1316,28 @@ 1316 1316 1317 1317 ==== **Uplink payload mode** ==== 1318 1318 1319 -((( 1320 1320 Define to use one uplink or multiple uplinks for the sampling. 1321 -))) 1322 1322 1323 -((( 1324 1324 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1325 -))) 1326 1326 1327 -* ((( 1328 -**AT Command:** 1329 -))) 1149 +* **AT Command:** 1330 1330 1331 1331 (% class="box infomessage" %) 1332 1332 ((( 1333 -((( 1334 1334 **AT+DATAUP=0** 1335 1335 ))) 1336 -))) 1337 1337 1338 1338 (% class="box infomessage" %) 1339 1339 ((( 1340 -((( 1341 1341 **AT+DATAUP=1** 1342 1342 ))) 1343 -))) 1344 1344 1345 -((( 1346 - 1347 -))) 1348 1348 1349 -* ((( 1350 -**Downlink Payload:** 1351 -))) 1162 +* **Downlink Payload:** 1352 1352 1353 -((( 1354 1354 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1355 -))) 1356 1356 1357 -((( 1358 1358 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1359 -))) 1360 1360 1361 1361 1362 1362 ... ... @@ -1374,49 +1374,26 @@ 1374 1374 1375 1375 ==== **Clear RS485 Command** ==== 1376 1376 1377 -((( 1378 1378 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1379 -))) 1380 1380 1381 -((( 1382 - 1383 -))) 1384 1384 1385 -* ((( 1386 -**AT Command:** 1387 -))) 1187 +* **AT Command:** 1388 1388 1389 1389 ((( 1390 1390 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1391 1391 ))) 1392 1392 1393 -((( 1394 1394 Example screen shot after clear all RS485 commands. 1395 -))) 1396 1396 1397 -((( 1398 - 1399 -))) 1400 1400 1401 -((( 1402 1402 The uplink screen shot is: 1403 -))) 1404 1404 1405 -((( 1406 1406 [[image:1654134704555-320.png]] 1407 -))) 1408 1408 1409 -((( 1410 - 1411 -))) 1412 1412 1413 -* ((( 1414 -**Downlink Payload:** 1415 -))) 1201 +* **Downlink Payload:** 1416 1416 1417 -((( 1418 1418 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1419 -))) 1420 1420 1421 1421 1422 1422 ... ... @@ -1423,59 +1423,44 @@ 1423 1423 1424 1424 ==== **Set Serial Communication Parameters** ==== 1425 1425 1426 -((( 1427 1427 Set the Rs485 serial communication parameters: 1428 -))) 1429 1429 1430 -* ((( 1431 -**AT Command:** 1432 -))) 1212 +* **AT Command:** 1433 1433 1434 -((( 1435 1435 Set Baud Rate: 1436 -))) 1437 1437 1438 1438 (% class="box infomessage" %) 1439 1439 ((( 1440 -((( 1441 1441 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1219 +))) 1442 1442 1443 1443 Set UART Parity 1222 + 1223 +(% class="box infomessage" %) 1224 +((( 1444 1444 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1226 +))) 1445 1445 1446 1446 Set STOPBIT 1447 1447 1230 +(% class="box infomessage" %) 1231 +((( 1448 1448 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1449 1449 ))) 1450 -))) 1451 1451 1452 1452 1453 -* ((( 1454 -**Downlink Payload:** 1455 -))) 1236 +* **Downlink Payload:** 1456 1456 1457 -((( 1458 1458 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1459 -))) 1460 1460 1461 -((( 1462 1462 **Example:** 1463 -))) 1464 1464 1465 -* ((( 1466 -A7 01 00 60 same as AT+BAUDR=9600 1467 -))) 1468 -* ((( 1469 -A7 01 04 80 same as AT+BAUDR=115200 1470 -))) 1242 +* A7 01 00 60 same as AT+BAUDR=9600 1243 +* A7 01 04 80 same as AT+BAUDR=115200 1471 1471 1472 -((( 1473 1473 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1474 -))) 1475 1475 1476 -((( 1477 1477 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1478 -))) 1479 1479 1480 1480 1481 1481 ... ... @@ -1482,41 +1482,22 @@ 1482 1482 1483 1483 ==== **Control output power duration** ==== 1484 1484 1485 -((( 1486 1486 User can set the output power duration before each sampling. 1487 -))) 1488 1488 1489 -* ((( 1490 -**AT Command:** 1491 -))) 1256 +* **AT Command:** 1492 1492 1493 -((( 1494 1494 **Example:** 1495 -))) 1496 1496 1497 -((( 1498 1498 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1499 -))) 1500 1500 1501 -((( 1502 1502 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1503 -))) 1504 1504 1505 -((( 1506 - 1507 -))) 1508 1508 1509 -* ((( 1510 -**LoRaWAN Downlink Command:** 1511 -))) 1265 +* **LoRaWAN Downlink Command:** 1512 1512 1513 -((( 1514 1514 **07 01 aa bb** Same as AT+5VT=(aa bb) 1515 -))) 1516 1516 1517 -((( 1518 1518 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1519 -))) 1520 1520 1521 1521 1522 1522 ... ... @@ -1526,6 +1526,8 @@ 1526 1526 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1527 1527 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1528 1528 1279 + 1280 + 1529 1529 == 3.7 +3V3 Output == 1530 1530 1531 1531 ((( ... ... @@ -1603,14 +1603,22 @@ 1603 1603 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1604 1604 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1605 1605 1358 + 1359 + 1606 1606 == 3.10 Switch Jumper == 1607 1607 1608 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1609 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1610 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1362 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1363 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1364 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1365 +ISP position: Upgrade firmware via UART 1366 + 1611 1611 Flash position: Configure device, check running status. 1612 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1368 +))) 1369 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1370 +5V position: set to compatible with 5v I/O. 1371 + 1613 1613 3.3v position: set to compatible with 3.3v I/O., 1373 +))) 1614 1614 1615 1615 ((( 1616 1616 **+3.3V**: is always ON ... ... @@ -1658,7 +1658,15 @@ 1658 1658 (% class="box infomessage" %) 1659 1659 ((( 1660 1660 **AT+FDR** 1421 +))) 1422 + 1423 +(% class="box infomessage" %) 1424 +((( 1661 1661 **AT+NJM=0** 1426 +))) 1427 + 1428 +(% class="box infomessage" %) 1429 +((( 1662 1662 **ATZ** 1663 1663 ))) 1664 1664 ... ... @@ -1800,6 +1800,8 @@ 1800 1800 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1801 1801 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1802 1802 1571 + 1572 + 1803 1803 = 9. Packing Info = 1804 1804 1805 1805 (((