... ... @@ -1,9 +1,13 @@
1 1  (% style="text-align:center" %)
2 -[[image:1652947681187-144.png||height="404" width="404"]]
2 +[[image:1652947681187-144.png||height="385" width="385"]]
3 3  
4 4  
5 5  
6 6  
7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual**
8 +
9 +
10 +
7 7  **Table of Contents:**
8 8  
9 9  {{toc/}}
... ... @@ -63,7 +63,6 @@
63 63  ** Idle: 6uA@3.3v
64 64  ** 20dB Transmit: 130mA@3.3v
65 65  
66 -
67 67  **Interface for Model:**
68 68  
69 69  * 1 x RS485 Interface
... ... @@ -73,7 +73,6 @@
73 73  * 1 x Interrupt Interface
74 74  * 1 x Controllable 5V output, max
75 75  
76 -
77 77  **LoRa Spec:**
78 78  
79 79  * Frequency Range:
... ... @@ -92,9 +92,6 @@
92 92  * 127 dB Dynamic Range RSSI.
93 93  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
94 94  
95 -
96 -
97 -
98 98  == 1.3 Features ==
99 99  
100 100  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -106,9 +106,6 @@
106 106  * Support Modbus protocol
107 107  * Support Interrupt uplink
108 108  
109 -
110 -
111 -
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -118,9 +118,6 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
121 -
122 -
123 -
124 124  == 1.5 Firmware Change log ==
125 125  
126 126  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -204,7 +204,6 @@
204 204  
205 205  [[image:1652953414711-647.png||height="337" width="723"]]
206 206  
207 -
208 208  (((
209 209  The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method.
210 210  )))
... ... @@ -299,7 +299,7 @@
299 299  (((
300 300  **Description**
301 301  )))
302 -)))|=(% style="width: 210px;" %)(((
294 +)))|=(% style="width: 2100px;" %)(((
303 303  (((
304 304  **Example**
305 305  )))
... ... @@ -390,6 +390,7 @@
390 390  )))
391 391  )))
392 392  
385 +
393 393  === 3.3.2 Configure sensors ===
394 394  
395 395  (((
... ... @@ -403,17 +403,11 @@
403 403  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
404 404  |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
405 405  |AT+CFGDEV|(% style="width:80px" %)(((
406 -(((
407 407  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
408 -)))
409 409  
410 -(((
411 411  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
412 -)))
413 413  
414 -(((
415 415  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
416 -)))
417 417  )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
418 418  
419 419  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
... ... @@ -884,7 +884,7 @@
884 884  )))
885 885  
886 886  (((
887 -**}**
874 +}
888 888  
889 889  
890 890  )))
... ... @@ -914,6 +914,7 @@
914 914  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
915 915  )))
916 916  
904 +
917 917  === 3.5.1 Common Commands: ===
918 918  
919 919  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1437,16 +1437,34 @@
1437 1437  (((
1438 1438  (((
1439 1439  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1428 +)))
1429 +)))
1440 1440  
1431 +(((
1441 1441  Set UART Parity
1433 +)))
1434 +
1435 +(% class="box infomessage" %)
1436 +(((
1437 +(((
1442 1442  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1439 +)))
1440 +)))
1443 1443  
1442 +(((
1444 1444  Set STOPBIT
1444 +)))
1445 1445  
1446 +(% class="box infomessage" %)
1447 +(((
1448 +(((
1446 1446  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1447 1447  )))
1448 1448  )))
1449 1449  
1453 +(((
1454 +
1455 +)))
1450 1450  
1451 1451  * (((
1452 1452  **Downlink Payload:**
... ... @@ -1524,6 +1524,7 @@
1524 1524  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1525 1525  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1526 1526  
1533 +
1527 1527  == 3.7 +3V3 Output ==
1528 1528  
1529 1529  (((
... ... @@ -1601,14 +1601,21 @@
1601 1601  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1602 1602  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1603 1603  
1611 +
1604 1604  == 3.10 Switch Jumper ==
1605 1605  
1606 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1607 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1608 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1614 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1615 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1616 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1617 +ISP position: Upgrade firmware via UART
1618 +
1609 1609  Flash position: Configure device, check running status.
1610 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1620 +)))
1621 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1622 +5V position: set to compatible with 5v I/O.
1623 +
1611 1611  3.3v position: set to compatible with 3.3v I/O.,
1625 +)))
1612 1612  
1613 1613  (((
1614 1614  **+3.3V**: is always ON
... ... @@ -1656,7 +1656,15 @@
1656 1656  (% class="box infomessage" %)
1657 1657  (((
1658 1658  **AT+FDR**
1673 +)))
1674 +
1675 +(% class="box infomessage" %)
1676 +(((
1659 1659  **AT+NJM=0**
1678 +)))
1679 +
1680 +(% class="box infomessage" %)
1681 +(((
1660 1660  **ATZ**
1661 1661  )))
1662 1662  
... ... @@ -1798,6 +1798,7 @@
1798 1798  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1799 1799  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1800 1800  
1823 +
1801 1801  = 9. Packing Info =
1802 1802  
1803 1803  (((