Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -63,7 +63,6 @@ 63 63 ** Idle: 6uA@3.3v 64 64 ** 20dB Transmit: 130mA@3.3v 65 65 66 - 67 67 **Interface for Model:** 68 68 69 69 * 1 x RS485 Interface ... ... @@ -73,7 +73,6 @@ 73 73 * 1 x Interrupt Interface 74 74 * 1 x Controllable 5V output, max 75 75 76 - 77 77 **LoRa Spec:** 78 78 79 79 * Frequency Range: ... ... @@ -92,9 +92,6 @@ 92 92 * 127 dB Dynamic Range RSSI. 93 93 * Automatic RF Sense and CAD with ultra-fast AFC. 94 94 95 - 96 - 97 - 98 98 == 1.3 Features == 99 99 100 100 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -106,9 +106,6 @@ 106 106 * Support Modbus protocol 107 107 * Support Interrupt uplink 108 108 109 - 110 - 111 - 112 112 == 1.4 Applications == 113 113 114 114 * Smart Buildings & Home Automation ... ... @@ -118,9 +118,6 @@ 118 118 * Smart Cities 119 119 * Smart Factory 120 120 121 - 122 - 123 - 124 124 == 1.5 Firmware Change log == 125 125 126 126 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -204,7 +204,6 @@ 204 204 205 205 [[image:1652953414711-647.png||height="337" width="723"]] 206 206 207 - 208 208 ((( 209 209 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 210 210 ))) ... ... @@ -291,28 +291,28 @@ 291 291 ))) 292 292 293 293 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 294 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 295 295 ((( 296 296 **AT Commands** 297 297 ))) 298 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 299 299 ((( 300 300 **Description** 301 301 ))) 302 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 303 303 ((( 304 304 **Example** 305 305 ))) 306 306 ))) 307 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 308 308 ((( 309 309 AT+BAUDR 310 310 ))) 311 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 312 312 ((( 313 313 Set the baud rate (for RS485 connection). Default Value is: 9600. 314 314 ))) 315 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 316 316 ((( 317 317 ((( 318 318 AT+BAUDR=9600 ... ... @@ -325,11 +325,11 @@ 325 325 ))) 326 326 ))) 327 327 ))) 328 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 329 329 ((( 330 330 AT+PARITY 331 331 ))) 332 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 333 333 ((( 334 334 ((( 335 335 Set UART parity (for RS485 connection) ... ... @@ -341,7 +341,7 @@ 341 341 Default Value is: no parity. 342 342 ))) 343 343 ))) 344 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 345 345 ((( 346 346 ((( 347 347 AT+PARITY=0 ... ... @@ -354,11 +354,11 @@ 354 354 ))) 355 355 ))) 356 356 ))) 357 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 358 358 ((( 359 359 AT+STOPBIT 360 360 ))) 361 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 362 362 ((( 363 363 ((( 364 364 Set serial stopbit (for RS485 connection) ... ... @@ -370,7 +370,7 @@ 370 370 Default Value is: 1bit. 371 371 ))) 372 372 ))) 373 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 374 374 ((( 375 375 ((( 376 376 AT+STOPBIT=0 for 1bit ... ... @@ -390,6 +390,8 @@ 390 390 ))) 391 391 ))) 392 392 385 + 386 + 393 393 === 3.3.2 Configure sensors === 394 394 395 395 ((( ... ... @@ -401,20 +401,14 @@ 401 401 ))) 402 402 403 403 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 404 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 405 -|AT+CFGDEV|(% style="width:80px" %)((( 406 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 407 407 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 408 -))) 409 409 410 -((( 411 411 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 412 -))) 413 413 414 -((( 415 415 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 416 -))) 417 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 418 418 419 419 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 420 420 ... ... @@ -884,7 +884,7 @@ 884 884 ))) 885 885 886 886 ((( 887 - **}**875 +{{{}}}} 888 888 889 889 890 890 ))) ... ... @@ -914,6 +914,8 @@ 914 914 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 915 915 ))) 916 916 905 + 906 + 917 917 === 3.5.1 Common Commands: === 918 918 919 919 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1437,16 +1437,34 @@ 1437 1437 ((( 1438 1438 ((( 1439 1439 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1430 +))) 1431 +))) 1440 1440 1433 +((( 1441 1441 Set UART Parity 1435 +))) 1436 + 1437 +(% class="box infomessage" %) 1438 +((( 1439 +((( 1442 1442 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1441 +))) 1442 +))) 1443 1443 1444 +((( 1444 1444 Set STOPBIT 1446 +))) 1445 1445 1448 +(% class="box infomessage" %) 1449 +((( 1450 +((( 1446 1446 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1447 1447 ))) 1448 1448 ))) 1449 1449 1455 +((( 1456 + 1457 +))) 1450 1450 1451 1451 * ((( 1452 1452 **Downlink Payload:** ... ... @@ -1524,6 +1524,8 @@ 1524 1524 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1525 1525 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1526 1526 1535 + 1536 + 1527 1527 == 3.7 +3V3 Output == 1528 1528 1529 1529 ((( ... ... @@ -1601,14 +1601,22 @@ 1601 1601 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1602 1602 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1603 1603 1614 + 1615 + 1604 1604 == 3.10 Switch Jumper == 1605 1605 1606 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1607 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1608 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1618 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1619 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1620 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1621 +ISP position: Upgrade firmware via UART 1622 + 1609 1609 Flash position: Configure device, check running status. 1610 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1624 +))) 1625 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1626 +5V position: set to compatible with 5v I/O. 1627 + 1611 1611 3.3v position: set to compatible with 3.3v I/O., 1629 +))) 1612 1612 1613 1613 ((( 1614 1614 **+3.3V**: is always ON ... ... @@ -1656,7 +1656,15 @@ 1656 1656 (% class="box infomessage" %) 1657 1657 ((( 1658 1658 **AT+FDR** 1677 +))) 1678 + 1679 +(% class="box infomessage" %) 1680 +((( 1659 1659 **AT+NJM=0** 1682 +))) 1683 + 1684 +(% class="box infomessage" %) 1685 +((( 1660 1660 **ATZ** 1661 1661 ))) 1662 1662 ... ... @@ -1798,6 +1798,8 @@ 1798 1798 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1799 1799 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1800 1800 1827 + 1828 + 1801 1801 = 9. Packing Info = 1802 1802 1803 1803 (((