Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -63,7 +63,6 @@ 63 63 ** Idle: 6uA@3.3v 64 64 ** 20dB Transmit: 130mA@3.3v 65 65 66 - 67 67 **Interface for Model:** 68 68 69 69 * 1 x RS485 Interface ... ... @@ -73,7 +73,6 @@ 73 73 * 1 x Interrupt Interface 74 74 * 1 x Controllable 5V output, max 75 75 76 - 77 77 **LoRa Spec:** 78 78 79 79 * Frequency Range: ... ... @@ -92,9 +92,6 @@ 92 92 * 127 dB Dynamic Range RSSI. 93 93 * Automatic RF Sense and CAD with ultra-fast AFC. 94 94 95 - 96 - 97 - 98 98 == 1.3 Features == 99 99 100 100 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -106,9 +106,6 @@ 106 106 * Support Modbus protocol 107 107 * Support Interrupt uplink 108 108 109 - 110 - 111 - 112 112 == 1.4 Applications == 113 113 114 114 * Smart Buildings & Home Automation ... ... @@ -118,9 +118,6 @@ 118 118 * Smart Cities 119 119 * Smart Factory 120 120 121 - 122 - 123 - 124 124 == 1.5 Firmware Change log == 125 125 126 126 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -290,28 +290,28 @@ 290 290 ))) 291 291 292 292 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 293 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 294 294 ((( 295 295 **AT Commands** 296 296 ))) 297 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 298 298 ((( 299 299 **Description** 300 300 ))) 301 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 302 302 ((( 303 303 **Example** 304 304 ))) 305 305 ))) 306 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 307 307 ((( 308 308 AT+BAUDR 309 309 ))) 310 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 311 311 ((( 312 312 Set the baud rate (for RS485 connection). Default Value is: 9600. 313 313 ))) 314 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 315 315 ((( 316 316 ((( 317 317 AT+BAUDR=9600 ... ... @@ -324,11 +324,11 @@ 324 324 ))) 325 325 ))) 326 326 ))) 327 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 328 328 ((( 329 329 AT+PARITY 330 330 ))) 331 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 332 332 ((( 333 333 ((( 334 334 Set UART parity (for RS485 connection) ... ... @@ -340,7 +340,7 @@ 340 340 Default Value is: no parity. 341 341 ))) 342 342 ))) 343 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 344 344 ((( 345 345 ((( 346 346 AT+PARITY=0 ... ... @@ -353,11 +353,11 @@ 353 353 ))) 354 354 ))) 355 355 ))) 356 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 357 357 ((( 358 358 AT+STOPBIT 359 359 ))) 360 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 361 361 ((( 362 362 ((( 363 363 Set serial stopbit (for RS485 connection) ... ... @@ -369,7 +369,7 @@ 369 369 Default Value is: 1bit. 370 370 ))) 371 371 ))) 372 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 373 373 ((( 374 374 ((( 375 375 AT+STOPBIT=0 for 1bit ... ... @@ -389,6 +389,8 @@ 389 389 ))) 390 390 ))) 391 391 385 + 386 + 392 392 === 3.3.2 Configure sensors === 393 393 394 394 ((( ... ... @@ -400,20 +400,14 @@ 400 400 ))) 401 401 402 402 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 403 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 404 -|AT+CFGDEV|(% style="width:80px" %)((( 405 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 406 406 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 407 -))) 408 408 409 -((( 410 410 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 411 -))) 412 412 413 -((( 414 414 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 415 -))) 416 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 417 417 418 418 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 419 419 ... ... @@ -883,7 +883,7 @@ 883 883 ))) 884 884 885 885 ((( 886 - **}**875 +{{{}}}} 887 887 888 888 889 889 ))) ... ... @@ -913,6 +913,8 @@ 913 913 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 914 914 ))) 915 915 905 + 906 + 916 916 === 3.5.1 Common Commands: === 917 917 918 918 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1240,13 +1240,9 @@ 1240 1240 [[image:1654133954153-643.png]] 1241 1241 1242 1242 1243 -* ((( 1244 -**Downlink Commands:** 1245 -))) 1234 +* **Downlink Commands:** 1246 1246 1247 -((( 1248 1248 **A9 aa** ~-~-> Same as AT+MBFUN=aa 1249 -))) 1250 1250 1251 1251 1252 1252 ... ... @@ -1253,60 +1253,32 @@ 1253 1253 1254 1254 ==== **RS485 command timeout** ==== 1255 1255 1256 -((( 1257 1257 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1258 -))) 1259 1259 1260 -((( 1261 1261 Default value: 0, range: 0 ~~ 5 seconds 1262 -))) 1263 1263 1264 -((( 1265 - 1266 -))) 1267 1267 1268 -* ((( 1269 -**AT Command:** 1270 -))) 1248 +* **AT Command:** 1271 1271 1272 1272 (% class="box infomessage" %) 1273 1273 ((( 1274 -((( 1275 1275 **AT+CMDDLaa=hex(bb cc)** 1276 1276 ))) 1277 -))) 1278 1278 1279 -((( 1280 1280 **Example:** 1281 -))) 1282 1282 1283 -((( 1284 1284 **AT+CMDDL1=1000** to send the open time to 1000ms 1285 -))) 1286 1286 1287 -((( 1288 - 1289 -))) 1290 1290 1291 -* ((( 1292 -**Downlink Payload:** 1293 -))) 1260 +* **Downlink Payload:** 1294 1294 1295 -((( 1296 1296 0x AA aa bb cc 1297 -))) 1298 1298 1299 -((( 1300 1300 Same as: AT+CMDDLaa=hex(bb cc) 1301 -))) 1302 1302 1303 -((( 1304 1304 **Example:** 1305 -))) 1306 1306 1307 -((( 1308 1308 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1309 -))) 1310 1310 1311 1311 1312 1312 ... ... @@ -1313,47 +1313,28 @@ 1313 1313 1314 1314 ==== **Uplink payload mode** ==== 1315 1315 1316 -((( 1317 1317 Define to use one uplink or multiple uplinks for the sampling. 1318 -))) 1319 1319 1320 -((( 1321 1321 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1322 -))) 1323 1323 1324 -* ((( 1325 -**AT Command:** 1326 -))) 1279 +* **AT Command:** 1327 1327 1328 1328 (% class="box infomessage" %) 1329 1329 ((( 1330 -((( 1331 1331 **AT+DATAUP=0** 1332 1332 ))) 1333 -))) 1334 1334 1335 1335 (% class="box infomessage" %) 1336 1336 ((( 1337 -((( 1338 1338 **AT+DATAUP=1** 1339 1339 ))) 1340 -))) 1341 1341 1342 -((( 1343 - 1344 -))) 1345 1345 1346 -* ((( 1347 -**Downlink Payload:** 1348 -))) 1292 +* **Downlink Payload:** 1349 1349 1350 -((( 1351 1351 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1352 -))) 1353 1353 1354 -((( 1355 1355 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1356 -))) 1357 1357 1358 1358 1359 1359 ... ... @@ -1371,49 +1371,26 @@ 1371 1371 1372 1372 ==== **Clear RS485 Command** ==== 1373 1373 1374 -((( 1375 1375 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1376 -))) 1377 1377 1378 -((( 1379 - 1380 -))) 1381 1381 1382 -* ((( 1383 -**AT Command:** 1384 -))) 1317 +* **AT Command:** 1385 1385 1386 1386 ((( 1387 1387 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1388 1388 ))) 1389 1389 1390 -((( 1391 1391 Example screen shot after clear all RS485 commands. 1392 -))) 1393 1393 1394 -((( 1395 - 1396 -))) 1397 1397 1398 -((( 1399 1399 The uplink screen shot is: 1400 -))) 1401 1401 1402 -((( 1403 1403 [[image:1654134704555-320.png]] 1404 -))) 1405 1405 1406 -((( 1407 - 1408 -))) 1409 1409 1410 -* ((( 1411 -**Downlink Payload:** 1412 -))) 1331 +* **Downlink Payload:** 1413 1413 1414 -((( 1415 1415 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1416 -))) 1417 1417 1418 1418 1419 1419 ... ... @@ -1420,59 +1420,44 @@ 1420 1420 1421 1421 ==== **Set Serial Communication Parameters** ==== 1422 1422 1423 -((( 1424 1424 Set the Rs485 serial communication parameters: 1425 -))) 1426 1426 1427 -* ((( 1428 -**AT Command:** 1429 -))) 1342 +* **AT Command:** 1430 1430 1431 -((( 1432 1432 Set Baud Rate: 1433 -))) 1434 1434 1435 1435 (% class="box infomessage" %) 1436 1436 ((( 1437 -((( 1438 1438 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1349 +))) 1439 1439 1440 1440 Set UART Parity 1352 + 1353 +(% class="box infomessage" %) 1354 +((( 1441 1441 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1356 +))) 1442 1442 1443 1443 Set STOPBIT 1444 1444 1360 +(% class="box infomessage" %) 1361 +((( 1445 1445 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1446 1446 ))) 1447 -))) 1448 1448 1449 1449 1450 -* ((( 1451 -**Downlink Payload:** 1452 -))) 1366 +* **Downlink Payload:** 1453 1453 1454 -((( 1455 1455 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1456 -))) 1457 1457 1458 -((( 1459 1459 **Example:** 1460 -))) 1461 1461 1462 -* ((( 1463 -A7 01 00 60 same as AT+BAUDR=9600 1464 -))) 1465 -* ((( 1466 -A7 01 04 80 same as AT+BAUDR=115200 1467 -))) 1372 +* A7 01 00 60 same as AT+BAUDR=9600 1373 +* A7 01 04 80 same as AT+BAUDR=115200 1468 1468 1469 -((( 1470 1470 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1471 -))) 1472 1472 1473 -((( 1474 1474 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1475 -))) 1476 1476 1477 1477 1478 1478 ... ... @@ -1479,41 +1479,22 @@ 1479 1479 1480 1480 ==== **Control output power duration** ==== 1481 1481 1482 -((( 1483 1483 User can set the output power duration before each sampling. 1484 -))) 1485 1485 1486 -* ((( 1487 -**AT Command:** 1488 -))) 1386 +* **AT Command:** 1489 1489 1490 -((( 1491 1491 **Example:** 1492 -))) 1493 1493 1494 -((( 1495 1495 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1496 -))) 1497 1497 1498 -((( 1499 1499 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1500 -))) 1501 1501 1502 -((( 1503 - 1504 -))) 1505 1505 1506 -* ((( 1507 -**LoRaWAN Downlink Command:** 1508 -))) 1395 +* **LoRaWAN Downlink Command:** 1509 1509 1510 -((( 1511 1511 **07 01 aa bb** Same as AT+5VT=(aa bb) 1512 -))) 1513 1513 1514 -((( 1515 1515 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1516 -))) 1517 1517 1518 1518 1519 1519 ... ... @@ -1523,6 +1523,8 @@ 1523 1523 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1524 1524 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1525 1525 1409 + 1410 + 1526 1526 == 3.7 +3V3 Output == 1527 1527 1528 1528 ((( ... ... @@ -1600,14 +1600,22 @@ 1600 1600 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1601 1601 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1602 1602 1488 + 1489 + 1603 1603 == 3.10 Switch Jumper == 1604 1604 1605 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1606 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1607 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1492 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1493 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1494 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1495 +ISP position: Upgrade firmware via UART 1496 + 1608 1608 Flash position: Configure device, check running status. 1609 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1498 +))) 1499 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1500 +5V position: set to compatible with 5v I/O. 1501 + 1610 1610 3.3v position: set to compatible with 3.3v I/O., 1503 +))) 1611 1611 1612 1612 ((( 1613 1613 **+3.3V**: is always ON ... ... @@ -1655,7 +1655,15 @@ 1655 1655 (% class="box infomessage" %) 1656 1656 ((( 1657 1657 **AT+FDR** 1551 +))) 1552 + 1553 +(% class="box infomessage" %) 1554 +((( 1658 1658 **AT+NJM=0** 1556 +))) 1557 + 1558 +(% class="box infomessage" %) 1559 +((( 1659 1659 **ATZ** 1660 1660 ))) 1661 1661 ... ... @@ -1797,6 +1797,8 @@ 1797 1797 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1798 1798 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1799 1799 1701 + 1702 + 1800 1800 = 9. Packing Info = 1801 1801 1802 1802 (((