Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -279,28 +279,28 @@ 279 279 ))) 280 280 281 281 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 282 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 283 283 ((( 284 284 **AT Commands** 285 285 ))) 286 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 287 287 ((( 288 288 **Description** 289 289 ))) 290 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 291 291 ((( 292 292 **Example** 293 293 ))) 294 294 ))) 295 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 296 296 ((( 297 297 AT+BAUDR 298 298 ))) 299 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 300 300 ((( 301 301 Set the baud rate (for RS485 connection). Default Value is: 9600. 302 302 ))) 303 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 304 304 ((( 305 305 ((( 306 306 AT+BAUDR=9600 ... ... @@ -313,11 +313,11 @@ 313 313 ))) 314 314 ))) 315 315 ))) 316 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 317 317 ((( 318 318 AT+PARITY 319 319 ))) 320 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 321 321 ((( 322 322 ((( 323 323 Set UART parity (for RS485 connection) ... ... @@ -329,7 +329,7 @@ 329 329 Default Value is: no parity. 330 330 ))) 331 331 ))) 332 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 333 333 ((( 334 334 ((( 335 335 AT+PARITY=0 ... ... @@ -342,11 +342,11 @@ 342 342 ))) 343 343 ))) 344 344 ))) 345 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 346 346 ((( 347 347 AT+STOPBIT 348 348 ))) 349 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 350 350 ((( 351 351 ((( 352 352 Set serial stopbit (for RS485 connection) ... ... @@ -358,7 +358,7 @@ 358 358 Default Value is: 1bit. 359 359 ))) 360 360 ))) 361 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 362 362 ((( 363 363 ((( 364 364 AT+STOPBIT=0 for 1bit ... ... @@ -378,6 +378,8 @@ 378 378 ))) 379 379 ))) 380 380 385 + 386 + 381 381 === 3.3.2 Configure sensors === 382 382 383 383 ((( ... ... @@ -389,20 +389,14 @@ 389 389 ))) 390 390 391 391 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 392 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 393 -|AT+CFGDEV|(% style="width:80px" %)((( 394 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 395 395 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 396 -))) 397 397 398 -((( 399 399 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 400 -))) 401 401 402 -((( 403 403 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 404 -))) 405 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - **}**875 +{{{}}}} 876 876 877 877 878 878 ))) ... ... @@ -902,6 +902,8 @@ 902 902 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 903 ))) 904 904 905 + 906 + 905 905 === 3.5.1 Common Commands: === 906 906 907 907 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1302,47 +1302,28 @@ 1302 1302 1303 1303 ==== **Uplink payload mode** ==== 1304 1304 1305 -((( 1306 1306 Define to use one uplink or multiple uplinks for the sampling. 1307 -))) 1308 1308 1309 -((( 1310 1310 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1311 -))) 1312 1312 1313 -* ((( 1314 -**AT Command:** 1315 -))) 1311 +* **AT Command:** 1316 1316 1317 1317 (% class="box infomessage" %) 1318 1318 ((( 1319 -((( 1320 1320 **AT+DATAUP=0** 1321 1321 ))) 1322 -))) 1323 1323 1324 1324 (% class="box infomessage" %) 1325 1325 ((( 1326 -((( 1327 1327 **AT+DATAUP=1** 1328 1328 ))) 1329 -))) 1330 1330 1331 -((( 1332 - 1333 -))) 1334 1334 1335 -* ((( 1336 -**Downlink Payload:** 1337 -))) 1324 +* **Downlink Payload:** 1338 1338 1339 -((( 1340 1340 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1341 -))) 1342 1342 1343 -((( 1344 1344 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1345 -))) 1346 1346 1347 1347 1348 1348 ... ... @@ -1360,49 +1360,26 @@ 1360 1360 1361 1361 ==== **Clear RS485 Command** ==== 1362 1362 1363 -((( 1364 1364 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1365 -))) 1366 1366 1367 -((( 1368 - 1369 -))) 1370 1370 1371 -* ((( 1372 -**AT Command:** 1373 -))) 1349 +* **AT Command:** 1374 1374 1375 1375 ((( 1376 1376 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1377 1377 ))) 1378 1378 1379 -((( 1380 1380 Example screen shot after clear all RS485 commands. 1381 -))) 1382 1382 1383 -((( 1384 - 1385 -))) 1386 1386 1387 -((( 1388 1388 The uplink screen shot is: 1389 -))) 1390 1390 1391 -((( 1392 1392 [[image:1654134704555-320.png]] 1393 -))) 1394 1394 1395 -((( 1396 - 1397 -))) 1398 1398 1399 -* ((( 1400 -**Downlink Payload:** 1401 -))) 1363 +* **Downlink Payload:** 1402 1402 1403 -((( 1404 1404 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1405 -))) 1406 1406 1407 1407 1408 1408 ... ... @@ -1409,59 +1409,44 @@ 1409 1409 1410 1410 ==== **Set Serial Communication Parameters** ==== 1411 1411 1412 -((( 1413 1413 Set the Rs485 serial communication parameters: 1414 -))) 1415 1415 1416 -* ((( 1417 -**AT Command:** 1418 -))) 1374 +* **AT Command:** 1419 1419 1420 -((( 1421 1421 Set Baud Rate: 1422 -))) 1423 1423 1424 1424 (% class="box infomessage" %) 1425 1425 ((( 1426 -((( 1427 1427 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1381 +))) 1428 1428 1429 1429 Set UART Parity 1384 + 1385 +(% class="box infomessage" %) 1386 +((( 1430 1430 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1388 +))) 1431 1431 1432 1432 Set STOPBIT 1433 1433 1392 +(% class="box infomessage" %) 1393 +((( 1434 1434 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1435 1435 ))) 1436 -))) 1437 1437 1438 1438 1439 -* ((( 1440 -**Downlink Payload:** 1441 -))) 1398 +* **Downlink Payload:** 1442 1442 1443 -((( 1444 1444 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1445 -))) 1446 1446 1447 -((( 1448 1448 **Example:** 1449 -))) 1450 1450 1451 -* ((( 1452 -A7 01 00 60 same as AT+BAUDR=9600 1453 -))) 1454 -* ((( 1455 -A7 01 04 80 same as AT+BAUDR=115200 1456 -))) 1404 +* A7 01 00 60 same as AT+BAUDR=9600 1405 +* A7 01 04 80 same as AT+BAUDR=115200 1457 1457 1458 -((( 1459 1459 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1460 -))) 1461 1461 1462 -((( 1463 1463 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1464 -))) 1465 1465 1466 1466 1467 1467 ... ... @@ -1468,41 +1468,22 @@ 1468 1468 1469 1469 ==== **Control output power duration** ==== 1470 1470 1471 -((( 1472 1472 User can set the output power duration before each sampling. 1473 -))) 1474 1474 1475 -* ((( 1476 -**AT Command:** 1477 -))) 1418 +* **AT Command:** 1478 1478 1479 -((( 1480 1480 **Example:** 1481 -))) 1482 1482 1483 -((( 1484 1484 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1485 -))) 1486 1486 1487 -((( 1488 1488 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1489 -))) 1490 1490 1491 -((( 1492 - 1493 -))) 1494 1494 1495 -* ((( 1496 -**LoRaWAN Downlink Command:** 1497 -))) 1427 +* **LoRaWAN Downlink Command:** 1498 1498 1499 -((( 1500 1500 **07 01 aa bb** Same as AT+5VT=(aa bb) 1501 -))) 1502 1502 1503 -((( 1504 1504 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1505 -))) 1506 1506 1507 1507 1508 1508 ... ... @@ -1512,6 +1512,8 @@ 1512 1512 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1513 1513 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1514 1514 1441 + 1442 + 1515 1515 == 3.7 +3V3 Output == 1516 1516 1517 1517 ((( ... ... @@ -1589,14 +1589,22 @@ 1589 1589 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1590 1590 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1591 1591 1520 + 1521 + 1592 1592 == 3.10 Switch Jumper == 1593 1593 1594 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1595 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1596 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1524 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1525 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1526 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1527 +ISP position: Upgrade firmware via UART 1528 + 1597 1597 Flash position: Configure device, check running status. 1598 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1530 +))) 1531 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1532 +5V position: set to compatible with 5v I/O. 1533 + 1599 1599 3.3v position: set to compatible with 3.3v I/O., 1535 +))) 1600 1600 1601 1601 ((( 1602 1602 **+3.3V**: is always ON ... ... @@ -1644,7 +1644,15 @@ 1644 1644 (% class="box infomessage" %) 1645 1645 ((( 1646 1646 **AT+FDR** 1583 +))) 1584 + 1585 +(% class="box infomessage" %) 1586 +((( 1647 1647 **AT+NJM=0** 1588 +))) 1589 + 1590 +(% class="box infomessage" %) 1591 +((( 1648 1648 **ATZ** 1649 1649 ))) 1650 1650 ... ... @@ -1786,6 +1786,8 @@ 1786 1786 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1787 1787 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1788 1788 1733 + 1734 + 1789 1789 = 9. Packing Info = 1790 1790 1791 1791 (((